IR 05000335/1988023

From kanterella
Jump to navigation Jump to search
Insp Repts 50-335/88-23 & 50-389/88-23 on 880925-30.No Violations Noted.Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness & Security Organization.Details Withheld (Ref 10CFR2.790(d) & 73.21)
ML20206E630
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 11/02/1988
From: Mcguire D, Stansberry W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20206E627 List:
References
50-335-88-23, 50-389-88-23, NUDOCS 8811180146
Download: ML20206E630 (1)


Text

i .

,

a ;~ 3.o a. [ UNITED STATES jo

,j

'*

NUCLEAR REGULATORY COMMISSION REGION 11 O

101 MARIETTA ST .,,,, ATLANTA, GEORGIA 30323

.

NOV 2 1988 Report Nos.: 50-335/88-23 and 50-389/88-23 Licensee: Florida Power and Light Company 9250 West Flagler Street Miami, FL 33102 Docket Nos.: 50-335 and 50-389 License Nos.: DPR-67 arid NPF-16 Facility Name: St. Lucie 1 and 2 Inspection Conducted: Se t ber P.E-30, 1988 Ingeetc :

//7.; M .,... - 1,. // p7 V."W. Stansb ry, Phys' cal

~

curity Inspector Dpte/ Signed Approved by: b D. KcGuire, Section Chief

.. ///7ki Dat,e Signed Physical Security Section Division of Radiation Safety and Safeguards SUMMARY Scope: This routine unannounced inspection was conducted in the areas of Security Plan and Implementing Procedures; Management Effectiveness; Security Organization; Records and Reports; Testing and Maintenance; Locks, Keys and Combinations; Physical Barriers-Protected and Vital Areas; Lighting; Compensatory Measures; Assessment Aids; Access Control-Personnel, Packages and Vehicles; Detection Aids-Protected and Vital Areas; Alarm Stations; Personnel Training and Qualification; Safeguards Contingency Plan; and Physical Protection

Safeguards Informatio Results
In the areas inspected, violations were not identifie Howeve*,

the fol'owing Inspector Follow-up Items were identified: Physical Security Plan commitments for administrative controls missing (Paragraph 5). Perimeter lighting lacked appropriate maintenance (Paragrrph 6). Administrative controls of the Key and Core Program needs improvement (Paragraph 7). Perimeter detection aids need calibration (Paragraph 16). Contingency Plan needs to address Radiological Emergencies (Paragraph 20).

8811180146 001102 PDR ADOCK 05000335 oco m,r i err u+m3 ew* "'

G PNU L'OS_T%

, _ ,. r , n oe- ,- no

- ~, - - - . _ _ _ - _ _