i

.

,

a

~

3.o a. [

UNITED STATES j

,j NUCLEAR REGULATORY COMMISSION O

o

'*

REGION 11 101 MARIETTA ST N.W.

.,,,,

ATLANTA, GEORGIA 30323

.

NOV 2 1988 Report Nos.: 50-335/88-23 and 50-389/88-23 Licensee:

Florida Power and Light Company 9250 West Flagler Street Miami, FL 33102 Docket Nos.:

50-335 and 50-389 License Nos.: DPR-67 arid NPF-16 Facility Name:

St. Lucie 1 and 2 Inspection Conducted:

Se t ber P.E-30, 1988

//7.; M.,... -

1,.j.4

//

p7 Ingeetc :

V."W. Stansb ry, Phys' cal curity Inspector Dpte/ Signed

~

Approved by:

b

..

///7ki D. KcGuire, Section Chief Dat,e Signed Physical Security Section Division of Radiation Safety and Safeguards SUMMARY Scope:

This routine unannounced inspection was conducted in the areas of Security Plan and Implementing Procedures; Management Effectiveness; Security Organization; Records and Reports; Testing and Maintenance; Locks, Keys and Combinations; Physical Barriers-Protected and Vital Areas; Lighting; Compensatory Measures; Assessment Aids; Access Control-Personnel, Packages and Vehicles; Detection Aids-Protected and Vital Areas; Alarm Stations; Personnel Training and Qualification; Safeguards Contingency Plan; and Physical Protection

Safeguards Information.

Results:

In the areas inspected, violations were not identified.

Howeve*,

the fol'owing Inspector Follow-up Items were identified:

1.

Physical Security Plan commitments for administrative controls missing (Paragraph 5).

2.

Perimeter lighting lacked appropriate maintenance (Paragrrph 6).

3.

Administrative controls of the Key and Core Program needs improvement (Paragraph 7).

4.

Perimeter detection aids need calibration (Paragraph 16).

5.

Contingency Plan needs to address Radiological Emergencies (Paragraph 20).

8811180146 001102 PDR ADOCK 05000335 G

PNU oco m,r i err u+m3 ew* "' L'OS_T%,- o

, _,. r,

n oe-n

- ~,

-

- -. _ _ _ - _ _