IR 05000334/2014301

From kanterella
Jump to navigation Jump to search
Er 05000334/2014301; July 7-14, 2014; Beaver Valley Power Station, Unit 1; Initial Operator Licensing Examination Report
ML14251A006
Person / Time
Site: Beaver Valley
(DPR-066)
Issue date: 09/04/2014
From: Diane Jackson
Division of Reactor Safety I
To: Emily Larson
FirstEnergy Nuclear Generation
Jackson D
References
IR-2014-301
Download: ML14251A006 (11)


Text

SUBJECT:

BEAVER VALLEY POWER STATION, UNIT 1 - NRC INITIAL OPERATOR LICENSING EXAMINATION REPORT 05000334/2014301

Dear Mr. Larson:

On July 14, 2014, the U.S. Nuclear Regulatory Commission (NRC) completed an examination at Beaver Valley Power Station, Unit 1. The enclosed examination report documents the examination results, which were discussed on August 13, 2014, with Messrs. Chris Hynes and Eric Loehlien, and other members of your staff.

The examination included the evaluation of four applicants for reactor operator licenses, and three applicants for instant senior reactor operator licenses. The written and operating examinations were developed using NUREG-1021, "Operator Licensing Examination Standards for Power Reactors," Revision 9, Supplement 1. The license examiners determined that seven of the seven applicants satisfied the requirements of 10 CFR Part 55, and the appropriate licenses were issued on August 13, 2014.

No findings were identified during this examination.

In accordance with Title 10 of Code of Federal Regulation (CFR), 10 CFR 2.390 of the NRC's

"Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs Agencywide Documents Access Management System (ADAMS).

ADAMS is accessible from the NRC Web site http://www.nrc.gov/reading-rm/adams.html#web-based-adams (the Public Electronic Reading Room).

Sincerely,

/RA/

Donald E. Jackson, Chief Operations Branch

Division of Reactor Safety

September 4, 2014 Docket No.: 50-334 License No.: DPR-66

Enclosure: Examination Report 05000334/2014301 w/Attachment: Supplementary Information

ML14251A006

SUNSI Review Non-Sensitive Publicly Available

OFFICE RI/DRS/OB RI/DRS/OB

RI/DRS/OB NAME BFuller/BF CBixler/CB

DJackson/DJ DATE 09/04/2014 09/04/2014

09/04/2014 Distribution: via email:

W. Dean, RA (R1ORAMAIL Resource)

D. Lew, DRA (R1ORAMAIL Resource)

H. Nieh, DRP (R1DRPMAIL Resource)

M. Scott, DRP (R1DRPMail Resource)

J. Trapp, DRS (R1DRSMail Resource)

B. Welling, DRS (R1DRSMail Resource)

S. Kennedy, DRP L. Cline, Acting, DRP C. Roettgen, DRP B. Bollinger, DRP J. Krafty, DRP, SRI E. Andrews, DRP, Actg RI (6-15 - 9-20)

C. Bixler, DRS B. Fuller, DRS D. Jackson, DRS P. Garrett, DRP, Resident AA A. Bowers, RI OEDO RidsNrrPMBeaverValley Resource RidsNrrDorlLpl1-2 Resource ROPreports Resource

Enclosure EXAMINATION REPORT

U.S. NUCLEAR REGULATORY COMMISSION

REGION I

Docket No.

50-334 License No.

DPR-66 Report No.

05000334/2014301 Licensee:

FirstEnergy Nuclear Generation Facility:

Beaver Valley Power Station, Unit 1 Location:

P.O. Box 4, Shippingport, PA 15077-0004 Dates:

July 7-11, 2014 (Operating Test Administration)

July 14, 2014 (Written Examination Administration)

July 18, 2014 (Licensee Submitted Post Exam Package)

August 4, 2014 (NRC Examination Grading)

August 13, 2014 (Licenses Issued)

Examiners:

B. Fuller, Chief Examiner, Operations Branch J. DAntonio, Senior Operations Engineer P. Presby, Senior Operations Engineer T. Hedigan, Operations Engineer

Approved By:

Donald E. Jackson, Chief Operations Branch Division of Reactor Safety

Enclosure

SUMMARY

ER 05000334/2014301; July 7-14, 2014; Beaver Valley Power Station, Unit 1; Initial Operator

Licensing Examination Report.

Four NRC examiners evaluated the competency of four applicants for reactor operator licenses and three applicants for instant senior reactor operator licenses at Beaver Valley Power Station,

Unit 1. The facility licensee developed the examinations using NUREG-1021, "Operator Licensing Examination Standards for Power Reactors," Revision 9, Supplement 1. The written examination was administered by the facility on July 14, 2014. NRC examiner(s) administered the operating tests on July 7-11, 2014. The NRC examiner(s) determined that seven of the seven applicants satisfied the requirements of 10 CFR Part 55, and the appropriate licenses have been issued.

NRC-Identified and Self-Revealing Findings

No findings were identified.

Licensee-Identified Violations

None.

REPORT DETAILS

OTHER ACTIVITIES (OA)

4OA5 Other Activities (Initial Operator License Examination)

.1 License Applications

a. Scope

The examiners reviewed all seven license applications submitted by the licensee to ensure the applications reflected that each applicant satisfied relevant license eligibility requirements. The applications were submitted on NRC Form 398, Personal Qualification Statement, and NRC Form 396, Certification of Medical Examination by Facility Licensee. The examiners also audited all seven of the license applications in detail to confirm that they accurately reflected the subject applicants qualifications. This audit focused on the applicants experience and on-the-job training, including control manipulations that provided significant reactivity changes.

b. Findings

No findings were identified.

.2 Operator Knowledge and Performance

a. Examination Scope

On July 14, 2014, the licensee proctored the administration of the written examinations to all seven applicants. The licensee staff graded the written examinations, analyzed the results, and presented their analysis to the NRC on July 18, 2014.

The NRC examination team administered the various portions of the operating examination to all seven applicants on July 7-11, 2014. The four applicants for reactor operator licenses participated in two to three dynamic simulator scenarios, in a control room and facilities walkthrough test consisting of eleven system tasks, and an administrative test consisting of four administrative tasks. The three applicants seeking an instant senior reactor operator license participated in two to three dynamic simulator scenarios, a control room and facilities walkthrough test consisting of ten system tasks, and an administrative test consisting of five administrative tasks.

b. Findings

All seven of the applicants passed all parts of the operating test. For the written examinations, the reactor operator applicants average score was 89 percent and ranged from 80 to 96 percent, the senior operator applicants average score was 91 percent and ranged from 86 to 96 percent. The overall written examination average was 90 percent.

The NRC examiners completed the final grading of the written examination on August 4, 2014, and conducted a review of each missed question to determine the accuracy and validity of the examination questions. Chapter ES-403 and Form ES-403-1 of NUREG 1021 require the licensee to analyze the validity of any written examination questions that were missed by half or more of the applicants. The licensee conducted this performance analysis for two questions that met these criteria and submitted the analysis to the chief examiner. The licensee determined the two questions that were missed by more than half of the applicants were valid. The licensee submitted one post-examination question comment on July 18, 2014, recommending acceptance of two correct answers for one question.

The NRC reviewed the facilitys post-exam comment submittal package and accepted the facility recommendation on the one question. The key for Question #43 was changed to accept Choice D in addition to original Key Answer C. The text of the examination questions, the licensees examination analysis, and the licensees post-examination comments with the NRC resolutions may be accessed in the ADAMS system under the accession numbers noted in the Attachment 1. In accordance with current NRC policy the release of this written examination will be delayed for two years.

.3 Initial Licensing Examination Development

a. Examination Scope

The facility licensee developed the examinations in accordance with NUREG-1021, Revision 9, Supplement 1. All licensee facility training and operations staff involved in examination preparation and validation were listed on a security agreement. The facility licensee submitted both the written and operating examination outlines on April 7, 2014.

The chief examiner reviewed the outlines against the requirements of NUREG-1021, and provided comments to the licensee. The facility licensee submitted the draft examination package on May 7, 2014. The chief examiner reviewed the draft examination package against the requirements of NUREG-1021, and provided comments to the licensee on the examination on June 12, 2014. The NRC conducted an onsite validation of the operating examinations and provided further comments during the week of June 9, 2014. The licensee satisfactorily completed comment resolution on June 19, 2014.

b. Findings

The NRC approved the initial examination outline and advised the licensee to proceed with the operating examination development.

The examiners determined that the written and operating examinations initially submitted by the licensee were within the range of acceptability expected for a proposed examination.

No findings were identified.

.4 Simulation Facility Performance

a. Examination Scope

The examiners observed simulator performance with regard to plant fidelity during the examination validation and administration.

b. Findings

No findings were identified.

.5 Examination Security

a. Examination Scope

The examiners reviewed examination security for examination development and during both the onsite preparation week and examination administration week for compliance with NUREG-1021 requirements. Plans for simulator security and applicant control were reviewed and discussed with licensee personnel.

b. Findings

No findings were identified.

4OA6 Meetings, Including Exit

The Branch Chief presented the examination results to Mr. Chris Hynes, Training Manager, and other members of the licensee's management staff on August 13, 2014.

The licensee did not identify any information or materials used during the examination as proprietary.

ATTACHMENTS:

SUPPLEMENTARY INFORMATION

KEY POINTS OF CONTACT

Licensee Personnel

T. Gaydosik, Exam Developer
M. Klingensmith, Exam Team
P. Eisenmann, Exam Team
R. Kristophel, Operations

NRC Personnel

J. Krafty, Senior Resident Inspector

ITEMS OPENED, CLOSED, AND DISCUSSED

Opened

NONE

Opened and Closed

NONE

Closed

NONE

Discussed

NONE

ADAMS DOCUMENTS REFERENCED