[b
o UNITED STATES r,, f
'g 8\\~
g NUCLEAR REGULATORY COMMISSION 4 45
REGION V
0,,
!
1990 N. CALIFORNIA BOULEVARD
% \\#
e SUITE 202, WALNUT CREEK PLAZA
- e*,*
WALNUT CREEK CALIFORNIA 94596 August 31, 1979 Docket tio. 50-312 Sacramento Municipal Utility District P. O. Boy. 15830 Sacramento, California 95830 Attention:
W. C. Walbridge General Manager Gentlemen:
Subject:
!1RC Inspection - Rancho Seco This letter refers to the inspection of your activities authorized under flRC License No. DPR-54 conducted by Messrs. E. J. Power, D. Schaefer and M. D. Schuster of this office on July 16-20, 1979.
It also refers to the discussion of our inspection findings held by the inspectors with P. Oubre and members of his staff on July 20, 1979.
The inspection included examination of activities related to physical protection against industrial sabotage and against theft of special nuclear material in accordance with applicable requirements of Title 10, Code of Federal Regulations, Part 73, " Physical Protection of Plants and Materials," your Security Plan, and license conditions pertaining to physical protection as described in the enclosed inspection report.
Within these areas, the inspection consisted of selective examinations of procedures and records, interviews with facility persomel and ob-servations by the inspectors.
Based on the results of this inspection, it appears that certain of your activities were not conducted in full compliance with URC requirements, as set forth in the Notice of Violation, enclosed herewith as Appendix A.
The items of noncompliance are categorized into the level as described in our correspondence to all NRC licensees dated December 31, 1974.
This notice is sent to~ you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office within 20 days of your receipt of this notice, a written statement of explanation in reply, including:
(1) steps which have been or will be taken by you to correct the violation, and the results achieved; (2) steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved.
7909240b W 000 m
n o u
' Sacramento Municipal Utility District-2-August 31, 1979 The findings during this inspection revealed instances of noncompliance regarding designated vehicles which are repetitive or similar to those which had been identified during previous liRC inspections.
Reference is made to llRC Inspections 50-312/77-10, 77-15 and 78-12. The actions taken to date have not been sufficiently extensive or timely to prevent recurrence.
In addition to your response to the apparent specific items of noncompliance, please provide a written explanation of action you plan to take to preclude such repetitive citations.
In accordance with Section 2.790(d) of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, documentation of findings of your control and accounting proceaures for safeguarding special nuclear materials and your facility security procedures are exempt from disclosure; therefore, Appendix A to this letter, the inspection report, and your response to the items listed in Appendix A will not be placed in the Public Document Room and will receive limited distribution.
Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely, T i i,,c 6 k -
R. H. Engelken Director Enclosures:
1.
Appendix A - tiotice of Violation 2.
Inspection Report
lio. 50-312/79-12 (IE-V-320)
cc w/ enclosures: (w/oattachments)
P. Oubre, SMUD
L. G. Schwieger, SMUD
W. Hammond, SMUD
n\\
o
n
OO
n