IR 05000295/1985026
| ML20134E238 | |
| Person / Time | |
|---|---|
| Site: | Zion File:ZionSolutions icon.png |
| Issue date: | 08/14/1985 |
| From: | Creed J, Drcuin B, Drouin B, Kniceley J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | |
| Shared Package | |
| ML20134E193 | List: |
| References | |
| 50-295-85-26, 50-304-85-27, NUDOCS 8508200100 | |
| Download: ML20134E238 (2) | |
Text
.
.
U.S. NUCLEAR REGULATORY COMMISSION
REGION III
Reports No. 50-295/85026(DRSS); 50-304/85027(DRSS)
Docket Nos. 50-295; 50-304 Safeguards Group IV Licenses No. DPR-39; DPR-48 Licensee:
Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690 Facility Name:
Zion Nuclear Station, Units 1 and 2 Inspection At:
Zion Station, Zion, Illinois Inspection Conducted:
July 22-25, 1985 Date of Last Physical Security Inspection:
March 25-28,19Q5
.
Type of Inspection:
Unannounced Physical Protection Inspection b
ud 6////45~
Inspectors:[o'J. RMnfceley Dat'e
'
Physical Security Inspector md 9) / Y7G~
B. Drouih Date Physical Security Inspector Approved By:
/K g/R. Creed, Chief Date Wafeguards Section
-
Inspection Summary Inspection on July 22-25, 1985 (Reports No. 50-295/85026(DRSS);
50-304/85027(DRSS))
Areas Inspected:
Included a review of the Security Plan and Implementing Procedures; Management Effectiveness; Security Organization; Security Program Audit; Records and Reports; Testing and Maintenance; Physical Barriers -
Protected Areas; Security System Power Supply; Lighting; Compensatory Measures; Assessment Aids; Detection Aids - Protected Areas; and Communications.
The inspectors reviewed the licensee's actions / performance relating to weaknesses /
concerns identified in previous inspection reports or which were identified as a result of a Region III analysis of previous inspection findings; 10 CFR 73.71(c)
security event reports and the previous SALP report.
The inspection involved 66 inspector-hours by two NRC inspectors.
The inspection began during the day shift.
Enclosure contains N.FORKION 8508200100 850814 pon separation this PDR ADOCK 05000295 G
PDR page is Decontrolled i
-
-
-
-
- -
- -
-
--
.
-.
Results:
The licensee was found to be in compliance with NRC requirements within the areas examined during this inspection.
One previously identified weakness was found to have been satisfactorily corrected.
(Details - UNCLASSIFIED )
(2