IR 05000282/1980007

From kanterella
Jump to navigation Jump to search
Nonproprietary Version of IE Insp Repts 50-282/80-07 & 50-306/80-07 on 800428-0502.Noncompliance Noted:Some Vital Area Physical Barriers Not Maintained & Alarm Devices Not tamper-indicating.Details Withheld (Ref 10CFR2.790)
ML19316B158
Person / Time
Site: Prairie Island  
Issue date: 05/21/1980
From: Creed J, Hind J, Pirtle G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19316B156 List:
References
50-282-80-07, 50-282-80-7, 50-306-80-07, 50-306-80-7, NUDOCS 8006110444
Download: ML19316B158 (2)


Text

- _ _ _ - _ _ _ _ _ _ _ _ _ _ _

_

_-__

.

O U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION III

'

Report No. 50-282/80-07; 50-306/80-07 Docket No. 50-282; 50-306 License No. DPR-42; DPR-60 Safeguards Group IV Licensee: Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 Facility Name: Prairie Island Units I and 2 Inspection At: Prairie Island Site, Red Wing, MN NSP Corporate Offices, Minneapolis, MN Inspection Conducted: April 28 - May 2, 1980 Date of Last Physical Security Inspection: November 26-30, 1979 Type of Inspection: Unannounced Physical Protection Inspectors:

A f.

Es

-

VJ. R. Creed 48'

Date Physical Security pecialist df w

,

s/u/s G. L. Pirtle 7"

' Date Physical Security Specialist Approved By:

d

.~ A. Hind, Chief Date

.

afeguards Branch Inspection Sununary Inspection on April 28 - May 2, 1980 (Report No. 50-282/80-07; 50-306/80-07)

Areas Inspected:

Included a review of the Security Plan; Security Program Audit; Security Organization; Protected Area Physical Barriers; Vital Area Physical Barriers; Lighting; Access Control (Identification, Authorization and Badging); Access Control (Search); Access Control (Escorting); Access Control (Vital Areas); Alarm Stations; Detection Aids; Assessment Aids; Communications; Testing and Maintenance; Compensatory Measures; Power 8006110fyy f

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

,

e

.

Supply; Response; Locks, Keys and Combinations; Records and Reports; Licensee Action of Previous Inspection Findings; Independent Inspection Effort.

The inspection involved 75 inspector hours onsite by two NRC inspectors including 14 inspection hours accomplished during offshift periods. The inspector began during the dayshift.

Results: The licensee was found to be in compliance with NRC requirements within the 20 areas examined during the inspection except for the following 5 items:

1.

Security Organization - The corrected vision of some security force personnel did not meet minimum requirements identified in the approved security plan.

(Deficiency)

2.

Vital Area Physical Barriers - Some vital area physical barriers were not properly maintained.

(Infraction)

3.

Access Control - Escorting An unattended designated vehicle located within the protected area was not disabled as required by the approved security plan.

(Deficiency)

4.

Detection Aids - The instrusion detection system (E-Field) was not adequately employed to detect penetration at some locations of the protected area boundary.

(Deficiency)

5.

Detection Aids - Some vital area alarm devices and monitoring systems were not tamper-indicating.

(Infraction)

,

f

-

i

!

l

.

-2 i