IR 05000275/1979003

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-275/79-03 on 790220-23.No Noncompliance Noted.Major Areas Inspected:Emergency Planning Facilities & Equipment,Training,Radiation Protection Staffing, Radioactive Waste Sys & Offsite Dose Calculation Manual
ML16340A452
Person / Time
Site: Diablo Canyon 
Issue date: 03/19/1979
From: North H, Rook H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML16340A451 List:
References
50-275-79-03, 50-275-79-3, NUDOCS 7905240768
Download: ML16340A452 (10)


Text

O.

U. S.

NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION V

Report No.

Docket No.

50-275 License No.

CPPR"39 gageguaeds Gseup Licensee:

Pacific Gas and Electric Com an 77 Beale Street San Francisco California 94106 Facility Name:

Diablo Can on Unit

Inspection at:

San Luis Obispo County, California Inspection conducted:

Februar 20-23, 1979 Inspectors:

H.

. North, Radiation Specialist DeSgnd Date Signed Da e Si ned Approved By:

H.

E.

Book, Chief, Fuel Facility and tlaterials Safety Branch Summary:

Date Signed Ins ection on Febr uar 20-23, 1979 Re ort 50-275/79-03 E

g 1 i,f l1ii d Ie i

ig'adiation protection, staffing, training, respiratory protection; radioactive waste systems, Offsite Dose Calculation Manual, monitoring procedures; preoperational testing; and plant tour.

The inspection involved 16 inspector-hours onsite by one inspector.

Results:

No items of noncompliance or deviations were identified.

V905 24 0 geo 8 RV Form 2'19 (

DETAILS Persons Contacted

  • R. Ramsay, Plant Superintendent
  • J. Shiffer, Assistant to Plant Superintendent
  • J. Giscoln, Power Plant Engineer
  • Pl. Norem, Startup Engineer
  • D. Backens, Maintenance Supervisor

"'R. Smith, Security Chief Supervisor

  • J. Shearer, Office Supervisor
  • C. Seward, gA Engineer J. Boots, Senior Chemical-Radiation Protection Engineer W. O'ara, Chemical Radiation Protection Engineer
  • J. Diamonon, gC Supervisor S. Fridley, Assistant Training Coordinator J. Arnold, Coordinating gC Engineer
  • Denotes those present at the exit inter'view.

Emer enc Plannin

- Facilities and E ui ment Records of the following test which had been approved and accepted

'y operations, Test Procedure No. 1.9,

~Prep Test of Coamunications

~S stem, were examined.

The purpose of the test was to verify the following: all intraplant communications links; fire and distress alarm features; manual and auto initiation of containment and site

,evacuation alarm; undervoltage alarm annunciation for fire alarm, containment and site evacuation alarm systems.

The test included verification of all inplant phones and phone jacks in five functional areas, call-in, call-out, code calls, fire alarm and conference call, regular and emergency.

The multichannel intercom, control room to slave stations, was tested.

The three plant to offsite communications links were verified.

The base radio network plant to Port San Luis guard house, Horro Bay Power Plant Switchyard, Diablo Canyon Information Center, San Luis Obispo County Sheriff s office and an alternate mobile station were verified.

The preop test report noted that on August 19, 1977, an unannounced test of the Site Emergency Alarm System resulted in the safe and orderly evacuation and accounting of all personnel in 30 minutes.

No items of noncompliance or deviations were identified.

Trainin

- Emer enc Plannin

, Radiation Protection A computerized training record program is being implemented.

The program will include records for all plant personnel, except operators, in the areas of radiation protection, emergency planning,

-2-security and quality control.

The program will identify individuals by name, social security number and job classification which desig-.

nates the training level required as specified in Administrative Procedure 8-2.

Copies of class attendance lists and exams will be the only paper records retained.

Standard radiation protection lecture notes have been prepared and included as training require-ments for particular job classifications.

Standard lecture notes in other areas will be prepared.

At, the time of the inspection, radiation protection training data had been entered in'he computer.

Records of training in areas other than radiation protection will be entered in the computer in the near futur e.

The licensee plans an extensive training effort to assure that all personnel have received the required training and retraining.

No items of noncompliance or deviations were identified.

Radiation Protection - Staffin The licensee is in the process of selecting three additional Radi-ation and Process Monitors (RPM's) which will increase the staff from eight to eleven.

Training of the last four RPM's added to the staff is approximately 955 complete.

No items of noncompliance or deviations, were identified.

Radiation Protection - Res irator Protection The licensee stated. that implementation of the airborne radioactivity surveillance and respiratory protection program would occur approxi-mately at the time of Unit 1 startup.

The inspector verified that the licensee's procedures addressed sections 8.d., e., g., h., i.,

1.,

m. and n. of the, Regulatory Guide 8.15.

No items of noncompliance or deviations were identified.

k'adioactive fJaste S stems - Offsite Dose Calculation Manual (OCDM)

The inspector examined a copy of the licensee's Chemical A~nal sis Procedure No. A-8, Offsite Dose Calculations and a draft copy of the OCDM Information prepared in response to the requirement to submit an OCDM as a part of the Radiological Effluent Technical Specifications.

The inspector commented that the documents did not appear to satisfy the intent of the OCDM but that the documents would be evaluated by NRR.

No items of noncompliance or deviations were identifie.

Gaseous Radioactive Waste S stems - flonitorin Procedure The licensee informed the inspector that the following previously approved procedures (IE Inspection Report 50-275/77-21)

would have to be revised as a result of the requirements for the OCDM.

Chemical Analysis Procedure No. F-8 Noble Gas Release Rate Calculations, calculator program for calculating the percent of the release rate limit for noble gases and the dose to the affected downwind sector at the site boundary.

Chemical Analysis Procedure No. F-9 Iodine, Particulate, Tritium and Carbon-14 Release rate Calculations, calculator program for ca culating the release rate, percent of maximum permissible release rate and the sector.

dose due to the release of, a mixture of radionuclides other than noble gases.

No items of noncompliance or deviations were identified.

8.

Preo erational Testin Test data from completed preoperational tests were examined to assure that the test results were within the previously established acceptance criteria and, as applicable, deviations from acceptance criteria were properly identified and disposed in accordance with the licensee's administrative procedures.

Records were examined for the following completed tests which had been approved and accepted by operations.

Test No.

19.2.14 23.11 Test Descri cion Flush and Pre-op of the Blowdown Deminerali zer Regenerant Receiver System Silver Zeolite Absorber and HEPA Filter Testing Test No. 23.11 was designed to meet the requirements of Regulatory

.

Guide 1.52 and ANSI N510-75, established the silver zeolite effective-ness at 99.99/ using refrigent R-11 and HEPA effectiveness at 99.99Ã using DOP.

The inspector's review of the test procedure 23.11 and observation of the tests was reported in IE Inspection Report 50-275/78-07.

No items of noncompliance or deviations were identifie C~

9.

Plant Tour The inspector toured various areas of common interest of the con-tainment, auxiliary and turbine buildings with the resident inspector

.

No items of noncompliance or deviations were identified.

10.

Exit Enterview The inspector met with licensee representatives

{denoted in Para-graph 1) at the conclusion of the inspection on February 23,,

1979.

The licensee was informed that no items of noncompliance had been identified.

The inspector summarized the scope and findings of the inspecion.

The inspector requested that the licensee keep the inspector informed as to the schedule of the emergency plan drill.

The inspector informed the licensee that at least 30 days prior to the first use of respiratory protection under the program authorized by 10 CFR 20.103, the licensee must make the notification required by 10 CFR 20.103(e).

I L

- ~