IR 05000269/1986025

From kanterella
Jump to navigation Jump to search
Partially Withheld Physical Security Insp Repts 50-269/86-25,50-270/86-25 & 50-287/86-25 on 860826-29 (Ref 10CFR2.790(d) & 73.21).No Noncompliance Noted.Major Areas Inspected:Security Plan & Implementing Procedures
ML16161A769
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 09/17/1986
From: Mcguire D, Tillman A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML16161A768 List:
References
50-269-86-25, 50-270-86-25, 50-287-86-25, NUDOCS 8609290449
Download: ML16161A769 (1)


Text

.AFEG UAR DS INFORMATION 6jk REGq UNITED STATES NUCLEAR REGULATORY COMMISSION o0

REGION II

101 MARIETTA STREET, ATLANTA, GEORGIA 30323 SEP 2 5 1986 Report Nos.:

50-269/86-25, 50-270/86-25, and 50-287/86-25 Licensee:

Duke Power Company 422 South Church Street Charlotte, NC 28242 Docket Nos.: 50-269, 50-270, and 50-287 License Nos.:

DPR-38, DPR-47, and DPR-55 Facility Name:

Oconee 1, 2, and 3 Inspection Cond ed:

August 26-29, 1986 Inspector:

-

/

A. Tillm, sical Security Inspector 4Date/Siged Approved by:

David R. McGuire, Chief, Physical Security Section

'gat6/Signed Nuclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards

SUMMARY Scope:

This routine, unannounced physical security inspection included a review and examination of the following areas:

Security Plan and Implementing Procedures; Management Effectiveness - Security Program; Security Organization; Testing and Maintenance, Physical Barriers - Vital Areas; Security System Power Supply; Lighting; Assessment Aids; Alarm Stations; Communications; Personnel Training and Qualification - General Requirements; Safeguards Contingency Plan Implementation Review; and Physical Protection Safeguards Informatio Results:

The Licensee was found to be in compliance with Regulatory Require ments within the 13 areas inspecte PDR ADOCK 05000269 PTOSURE CONTAINS SCG$GURDS INFORATION

',QN SEPARATION THIS PAGE ISDECONTROLLED;