IR 05000259/1985002

From kanterella
Jump to navigation Jump to search
Insp Repts 50-259/85-02,50-260/85-02 & 50-296/85-02 on 850121-25.No Violation or Deviation Noted.Major Areas Inspected:Design Program & Test Program
ML18029A428
Person / Time
Site: Turkey Point, Browns Ferry  
Issue date: 02/21/1985
From: Casey Smith, Upright C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML18029A427 List:
References
50-259-85-02, 50-259-85-2, 50-260-85-02, 50-260-85-2, 50-296-85-02, 50-296-85-2, NUDOCS 8503210138
Download: ML18029A428 (11)


Text

~g RECII Vp0 Cy

':@

+)t*w+

UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTASTREET, N.W.

ATLANTA,GEORGIA 30303 Report Nos.:

50-259/85-02, 50-260/85-02, and 50-296/85-02 Licensee:

Tennessee Valley Authority 500A Chestnut Street Chattanooga, TN 37401 Docket Nos.:

50-259, 50-260 and 50-296 License Nos.:

DPR-33, DPR-52, and DPR-68 Facility Name:

Browns Ferry 1, 2, and

Inspection Conducted:

January 21-25, 1984 Inspector:

C.

Smut Approved by:

'~ v~~

-.<..

"Cl.

C.

M Upright Section Chief Operation Branch Division of Reactor Safety Da e S1 ned ate Signed SUMMARY Scope:

This routine, unannounced inspection entailed 31 inspector-hours in the areas of design program and test program.

Results:

Of the two areas inspected, no violations or deviations were identified.

85032i0i38 850226 PDR ADOCK 05000250

PDR

REPORT DETAILS 1.

Persons Contacted Licensee Employees Contacted N. Beasley, BFEP Project Manager (Office of Engineering)

C. Bridges, equality Surveillance Coordinator L. Claray, equality Surveillance Supervisor C. Elledge, equality Assurance Evaluator

"A. Gordon, Browns Ferry Nuclear - Compliance R. Guthrie, Design Services Staff Chief

~G. Hall, Browns Ferry Design Services Manager

"G. Jones, Browns Ferry Nuclear Plant - Plant Manager

  • B. Morris, Browns Ferry Nuclear Plant - Compliance H.

Page, Shift Supervisor W. Thomison, Engineering Section Supervisor T. Ziegler, Browns Ferry Site Services Manager NRC Resident Inspectors

  • G. Paulk, Senior Resident Inspector

"C. Patterson, Resident Inspector

~C.

Brooks, Resident Inspector

"Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on January 25, 1985, with those persons indicated in paragraph 1 above.

The licensee acknowledged the inspection results.

The licensee did not identify as proprietary any of the materials provided to or reviewed by the inspectors during this inspection.

3.

Licensee Action on Previous Enforcement Matters This subject was not addressed in the inspection.

4.

Design Program (37702).

References:

(a)

CFR 50, Appendix B, equality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants, Criterion III.

(b)

Regulatory Guide 1. 64, equality Assurance Requirements for the Design of Nuclear Power Plants, Revision

(c)

ANSI N45.2. 11-1974, equality Assurance Requirements for the Design of Nuclear Power Plants

(d)

Regulatory Guide 1.33, guality Assurance Requirements (Operations)

November 1972 (e)

ANSI N18.7-1976, Adminsitrative Controls and guality Assurance for the Operational Phase of Nuclear Power Plants (f)

CFR Part 50.59, Changes, Tests and Experiments (g)

Technical Specifications Section 6.2, Review and Audit The inspector reviewed the licensee design change program required by references (a) through (g) to verify that these activities were conducted in accordance with regulatory requirements, industry guides and standards, and Technical Specifications.

The following criteria were used during the review to assess the overall acceptability of the established program:

Procedures have been established to control design changes which include assurance that a proposed change does not involve an unreviewed safety question or a change in technical specifications as required by

CFR 50.59.

Procedures and responsibilities for design control have been esta-blished including responsibilities and methods for conducting safety evaluations.

Administrative controls for design document control have been esta-blished for the following:

~

Controlling changes to approved design change documents

~

Controlling or recalling obsolete design change documents such as revised drawings and modification procedures

~

Release distribution of approved design change documents Administrative controls and responsibilities have been established commensurate with the time frame for implementation to assure that design changes will be incorporated into:

~

Plapt procedures

~

Operator training programs Plant drawings to reflect implemented design changes and modifica-tions Design controls require that implementation will be in accordance with approved procedure Design controls require assigning responsibility for identifying post-modification testing requirements and acceptance criteria in approved test procedures and for evaluation of test results.

Procedures assign responsibility and delineate the method for reporting design changes to the NRC in accordance with 10 CFR 50.59.

Controls require review and approval of temporary modifications in accordance with Section 6 of the Technical Specifications and

CFR 50.59.

The documents l.isted below were reviewed to verify that these criteria had been incorporated into the licensee design program:

NQAM, Part II, Section 1.5, Onsite Independent Review, 12/31/84 NQAM, Part II, Section 6.4, Control of Temporary Alterations, ll/5/84 NQAM, Part II, Section 3.2, Plant Modifications:

After Licensing, 12/31/84 NQAM, Part III, Section 4. 1, Quality Assurance Records, 12/31/84 NQAM, Part IV, Section 2, Design.Services, 12/31/84 NQAM, Part V, Section 2.8, Control of Design Requirements for Installa-tion (IO-QAP-2.8), 12/31/84 NQAM, Part V, Section 6.1, Configuration Drawing Control (ID-QAP-6.1),

12/31/84 NQAM, Part V, Section 6. 1, Configuration Drawing Control (IO-QAP-6. 1),

12/31/84 NQAM, Part V, Section 17.2, QA Records for Design and Construction ( IO-QAP-17. 2)

Procedure No. 0604.04, Unreviewed Safety Question (USQD)-Intent, Method, Review and Approval Standard Practice BF8.3, Plant Modifications Standard Practice BF8.2, Temporary Alterations, 7/1/83 Standard Practice BF8.7, Design Study Requests, 5/29/84

Standard Practice BF8.8, Non-Modification Work Plan, 6/20/84 Standard Practice BF8.9, Resolution of Backlog Work Plans The inspector reviewed the 1984 schedule to determine the number of survei llances conducted in the functional area of plant modifications.

The follow'ing surveillance reports were reviewed by the inspector:

Survey No:

SP-2l-gAS-84-171, Subject:

Advanced Drawings - Units 1 and 2, dated 4/25/84 Survey No:

0-6-gAS-84-58, Subject:

Survey of Temporary Alterations, dated 2/9/84.

The inspector verified that appropriate corrective actions were initiated for deficiencies identified during the performance of these surveys.

In addition, the inspector reviewed for adequacy the corrective actions taken by licensee management in response to the identified deficiencies.

The following document was reviewed by the inspector in connection with surveillance activities scheduled for 1985.

Memorandum from W.

E.

Andrews to H.

L. Abercrombie, J.

W.

Anderson, Subject:

Development of Survei.llance Program -

BFNP/RPIP Long-Term.

Action Item No, 5.3, dated May 14, 1984.

This memorandum describes a

proposed surveillance program which would consist of activity and program surveys.

Approximately 50 percent of the man-days scheduled will be allotted to activity surveys, with 35 percent allotted to program review and 15 percent to field activities associated with the program review.

The inspector reviewed the 1985 schedule for surveillance activities and discussed with licensee management the schedule of surveys of plant modification activities.

The inspector was informed that in accordance with the referenced memorandum, surveys of Maintenance/

Modification and Design Changes would be scheduled on an as-needed basis; i.e.,

the performance of "special surveys".

The inspector determined that activities to be surveyed include the following:

Modification Program Compliance to Work Plans (WPs)

ECN/FCR Control Post-modification Testing The inspector interviewed licensee management to determine the onsite organizational structure established to ensure effective management control of the design program and the degree of licensee management involvement in

the decision-making process pertaining to the design program.

The following document was reviewed by the inspector in conjunction with this effort:

Memorandum from W.

H.

Thompson, Manager of Employee Relations to W.

F. Willis, General Manager, Subject:

Organization Bulletin - Office of Nuclear Power and Division of Nuclear Services, dated January 4, 1985.

The above memorandum transmitted for approval revised organizational bulletins for the Office of Nuclear Power and the Division of Nuclear Services.

This memorandum was approved by W.

F. Willis Janaury 8, 1985.

Additionally, this document delineates responsibilities of the following onsite organizations among others:

Modifications Site Services Design Services The inspector reviewed two job descriptions of the managers of the above organizations to determine the authority and duties of persons and organiza-tions performing activities affecting the safety related functions of structures, systems, and components.

The inspector determined that licensee management is in the process of recruiting staff for the newly established organizations, in addition to preparing job descriptions and level I

principal tier instructions, for guidance of the staff members.

These activities are in accordance with licensee commitments delineated in the licensee long-term improvement program.

The inspector interviewed licensee management in the Office of Engineering (OE) to determine the adequacy of the administrative controls applicable to the design organization external and internal interfaces.

Particular attention was directed to the newly-established interface between the onsite Office of Engineering organization and the Design Services group.

Addi-tionally, interfaces within the site OE office and the Knoxville OE office were also discussed with licensee management.

The following documents were reviewed by the inspector in connection with this effort:

ENDES-EP 4.06, Field Change Requests Initiated by NUC PR, dated 2/24/84 f

ENDES-EP 4.22, Preliminary Design Change Requests (P-DCR's) - Handling, dated 4/13/83 ENDES-EP 4.52, Engineering Change Notices (ECNS) after licensing-Handling, dated 4/24/84 The inspector was informed by licensee management that the engineering procedures of ENDES, now renamed OE, are being reviewed by the Engineering equality Assurance Department.

They will be rewritten to reduce the number of procedures and consolidate program requirements into approximately

policy level procedures.

Licensee management further stated that with the reduction in numbers of the engineering procedures, the Browns Ferry Engineering Project (BFEP)

group would be required to prepare imple-menting procedures to delineate administrative controls applicable to day-to-day operation of the group.

Engineering type documents, such as engineering/design guides or standard specifications intended to provide technical guidance to staff members, would not be affected by these changes.

The inspector reviewed licensee design program documents to determine the program scope, content, and consistency with the organizational changes instituted on site.

The following document was reviewed in connection with this effort:

Memorandum from J.

A. Coffey to those listed, Subject:

Browns Ferry Nuclear Plant (BFNP) - Site Director Policy memorandum No 24-Title Tier Documents, dated 12/31/84.

The Site Director's Policy memorandum (SDPM-24) dated 12/31/84 delineates the requirements for establishing two types of site level instructions as fo1 1 ows:

Site Director's Policy Memoranda are nonauditable statements of the methods to conduct business'olicy memoranda will be issued by the site director.

Site Director Standard Practices (SP) are documents which describe and detail methods for ensuring that plant activities are conducted within the limits set by facility licenses, division requirements, and site policy.

SPs will be issued by the sitq director.

The memorandum further states that at BFN all policy and procedures which govern programmatic activities of more than one principal organization shall be issued in the format of one of the document types shown in the site tier level.

The memorandum addresses the establ i shment of principal tier-1 evel instructions and states that principal tier-level instructions shall be prepared by principal managers if clarification and enhancements to site tier-level procedures or additional instructions are deemed necessary to accomplish organizational missions in the safest and most efficient manner.

The hierarchial relationship of licensee program documents shown in the site tier-level, Attachment I to SDPM-24, is as follows:

Level I Principal Tier Instructions:

applicable to the Plant Manager, Site Services, Modification, and Design Services

Level II Site Tier Procedures:

Site Director Standard Practices or Site Director Policy Level III Office Tier Requirements:

NIZAM, NPRM, PMP, others Level IV Technical Specification, Topical Report, FSAR, TVA Code and others Site Director Policy Memorandum No.. 24 establishes the requirements of a

transition plan pursuant to the reorganization of Nuclear Power and states the requirements as follows:

Transition Plan Standard practices in effect at the plant manager level remain in effect for all site employees until they are superseded by a Site Director Standard Practice or unti 1 identified as a principal level document.

Site Director Standard Practices transition shall be initiated prior to March 1, 1985 Each site principal shall establish a principal tier-level instruction by March 1, 1985.

Each principal organization shall issue new instructions in their instruction format after this date.

Instruction-type material in standard practices currently at the plant manager level shall be reissued as deemed appropriate as principal-level instructions on a planned basis.

Site Services will status transition implementation monthly as a RPIP agenda item.

The inspector verified that licensee Level III office tier program documents contained in the NIZAM have been revised to reflect the reorganization of Nuclear Power and the organizational responsibilities and interfaces that presently exist on site.

Additionally, the inspector determined that most Level II site tier procedures have not been revised to be consistent with the upper tier Level II documents.

Principal tier instructions (Level I) have not yet been prepared by either Site Services or Design Services.

The inspector determined that these organizations are in the process of preparing these instructions and reviewed the following drafts prepared by Design Services:

DSIL 2, Design Organization Coordination Draft; B54352 (DSIL), - Handling of Nonconformances Reports (NCR's)

DSIL 1, Design Change Request Processing Plant Interface DSIL, Vendor Information Distribution

The inspector discussed with licensee management in Design Services and Site Services the requirements of.an integrated design and document control program and features of such a program that should be incorporated in Level II site tier procedures.

The inspector determined that, as a result of joint audit JA 8100-06, a

finding was issued in January 1982 against NUC PR and ENDES stating that

"as-constucted" drawings contain many errors and inaccuracies.

The following documents were reviewed by the inspector:

Memorandum from R.

D. Gutherie, Chairman, As-Constructed Task Force, BFNP, to J.

A.

Coffey Site Director, BFNP, Subject:

Browns Ferry Nuclear Plant (BFN) - Additional work plans assigned to the Backlog Work Team (BWT), dated 1/4/85'

Memorandum from G.

R.

Hall, Project Manager, Boiling Water Reactor Project, to L. J.

Cooney, Chief, Engineering Services Branch, Subject:

Browns Ferry Nuclear Plant

- Joint equality Assurance Audit JA 8100-06-Finding 0-9-Interim Report, dated'/16/84 Browns Ferry System for As-Constructed Drawings The Backlog Work Team (BWT) was formed i'n 1983 to close out approximately 450 open work-plans per BFNP/RPIP long-term action item 2. 1.

This effort.is still in progress.

Within this area no violations or deviations were identified in this area.

5.

Tests and Experiments (35749, 37703)

References:

(a)

CFR 50, Appendix B, guality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants..

(b)

Technical Specifications Section 6.2, Review and Audit (c)

Regulatory Guide 1.64, Revision 2, equality Assurance Requirements for the Design of Nuclear Power Plants (d)

ANSI N45.2. 11-1974, guality Assurance Requirements for the Design of Nuclear Power Plants

(e)

Regulatory Guide 1.33, Revision 2, guality Assurance Program Requirements (Operation)

(f)

ANSI N18. 7-1976, Administrative Controls and qua 1 ity Assur ance for the Operati ona1 Phase of Nuclear Power Plants The inspector reviewed the licensee's test and experiment program required by references (a) through (f) to verify that the program was in conformance with regulatory requirements, commitments in the application, and industry guides and standards.

The following criteria were used during the review to assess the overall acceptability of the established program:

A formal method has been established to handle all requests or proposals for conducting plant tests involving safety related components.

Provisions have been made to assure that all tests will be performed in accordance with approved written procedures.

. Responsibilities have been assigned for reviewing and approving test procedures.

A formal system, including assignment of responsibility, has been established to assure that all proposed tests will be reviewed to determine whether they are as described in the FSAR.

Responsibilities have been assigned to assure that a written safety evaluation required by 10 CFR 50.59 will be developed for each test to assure that it does not involve an unreviewed safety question or a

change in Technical Specifications.

The documents listed below were reviewed to verify that the previously listed criteria had been incorporated into the licensee tests and experi-ments program:

NIZAM Part II, Section 4.6, Special Test, dated 10/12/84 NIZAM Part II, Section 4.9, Handling of CSSE Test Deficiencies, dated 10/12/84 NIZAM Part II, Section 6.4, Control of'emporary Alterations, dated 11/5/84 Standard Practice BF17. 1, Special Tests, dated 8/10/83 Standard Practice BF17. 18, Unreviewed Safety question Determination, dated 8/28/84 Standard Practice BF8.2, Temporary Alterations, dated 8. 1.84 The inspector reviewed licensee tests and experiment program documents to determine the program scope, content,and consistency with the organizational changes instituted on site.

The inspector determined that licensee Level

III office tier requirements delineated in the NIZAM have been revised to address organizational responsibilities and interfaces that presently exist on site.

The Level II site tier procedures standard practices have not been revised to address the reorganization instituted on site and are therefore generally, inconsistent with program requirements delineated in the NIZAM.

The inspector verified that in accordance with J.

A. Coffey's memorandum dated 12/31/84 subject:

Browns Ferry Nuclear Plant (BFNP)-Site Director Policy memorandum No.

24, efforts are presently in progress for the esta-blishment of Site Director Standard Practices and Site Director's Policy memorandum to address this deficiency.

The inspector reviewed the following special tests:

Special Test 8418, Test Description:

Electrical Board Room Ventilation System Smoke Detector Temperature, Revision 0.

Special Test 8414, Test Description:

Diesel Generator Starts During SI 4.2.B-399, Revision 0.

The inspector verified that an Unreviewed Safety guestion Determination was performed in accordance with the requirements of 10 CFR 50.59 and that the format of the test procedure was consistent with the requirements delineated in the NIZAM, Part II, Section 4.6.

Within this area, no violations or deviations were identified in this area.