IR 05000245/1981004

From kanterella
Jump to navigation Jump to search
IE Insp Repts 50-245/81-04 & 50-336/81-03 on 810302-06.No Noncompliance Noted.Major Areas Inspected:Security Plan, Security Program Audit,Physical Barriers,Access Controls & Detection Aids.Details Withheld (Ref 10CFR2.790)
ML20009B935
Person / Time
Site: Millstone  
Issue date: 04/02/1981
From: Devlin J, Mckeown L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20009B933 List:
References
50-245-81-04, 50-245-81-4, 50-336-81-03, 50-336-81-3, NUDOCS 8107200041
Download: ML20009B935 (1)


Text

_ _ ___________ _______.

-

.

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

.

,

Regica I

,

50-245/81-04 Report No.

50-336/81-03 50-245 DPR-21 Docket No.

50-336 License No.

OPR-65 Safeguards Group IV Licensee:

N_ortheast Nuclear Energy Company P. O. Box 270 Hartford, Connecticut 06101 Facility Name: Millstone Nuclear Power Station, Units 1 and 2 Inspection at: Waterford, Connecticut Inspection conducted:

March 2-6, 1981 Date of last Physical Security Inspection:

September 21-26, 1980

-

Type of Inspection:

Routine, Unagnounced, Physical Protection 7d.7k sd dMb /

%/

Inspectors 7 L. M. McKeown, Physical Protection Inspector

'date signed date signed

,

Approved by:

/]

h 7-d. W. Devlin, Chief, Physical Protection

/ddte signed v/Section, Technical Inspection Branch Inspection Summary:

Inspection on March 2-6, 1981 (Combined Inspection Report Numbers 50-245/81-04 and 50-336/81-03)

Areas Inspected:

Included an examination of the Security Plan; Security Program Audit; Security Organization; Physical Barriers (Protected and Vitai Areas);

Lighting; Access Controls (Identification, Authorization and Badging); Access Controls (Search); Access Controls (Escorting); Access Controls (Vital Areas);

Alarm Stations; Detection Aids; Assessment Aids; Communications; Cccpensatory Measure's; Power Supply; Response; Locks, Keys and Combinations; Records and Reports. Also, a followup to a previously identified unresolved item and a Immediate Action Letter (IAL 80-28).

The inspection involved 41 inspector-hours onsite by one NRC regional based inspector. The inspection was begun during regular duty hours; 9 inspection hours were performed during off-shift periodr.

Results:

The licensee was found to be in compliance with NRC requirements within the 21 areas examined during this inspection.

~~

8107200041 810416 PDR ADOCK 05000245 G

PDR

_ - _ _ - _ _ _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _