IR 05000029/1975002

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-029/75-02 on 750212-14.Noncompliance Noted: Failure to Adhere to Written & Approved Procedures, & Failure to Make Adequate Surveys
ML19339A930
Person / Time
Site: Yankee Rowe
Issue date: 03/26/1975
From: Knapp P, Reynolds L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19339A924 List:
References
50-029-75-02, 50-29-75-2, NUDOCS 8011050713
Download: ML19339A930 (11)


Text

s

~ ~ ~ ~ --.

..

.m _

a

,,_

'

,, _ _

O

.

.

IE:I Form 12 (Jan.'5) (Rev)

'

.

U.S. NUCLEAR REGULATORY CO. FISSION T

OFFICE OF INSPECTION AND ENFORCEMENT

.

. REGION I 75-02 Docket No: 50-29 IE Inspection Report No:

License No: DPR-3 Licensee:

Yankee Atomic Electric Co.

,

20 Turnpike Road Priority:

C Westborough, Massachusetts 01581 Category:

.

Location:

Yankee Rowe: Rowe Massachusetts Sai'eguards s

Crt,p:

Type of Licensce: PWR, 600 MWt (W)

.

Routine," Unannounced Type of Inspection:

Dates of Inspection: February 12-14, 1975

.

Dates of Previous Inspection:

n n,,ry 7_tn to7s O

Reporting Inspector:

.

U Date n

p-Reynold diation Specialist Accompanying Inspector's:% _

k. M 3!% !7d~

'

P. J. Knapp, Senior Radiation Specialist Date Date

,

.

.

Date Other Accompanyin Personnel:

Date Reviewed By:

\\

--U, _ bd No A 3/s.f.[7/

'Datet PeDrJ.Knapp, Chief,Facilitiesbdiation

- -

  • '

Protection Section

.

f

!

.

.

l d011050//r3

. -.

.

,.

..

.

- - - - -. e

.

.

t

!

SUMMARY OF FINDINGS l

,

Enforcement Action A.

Items of Noncompliance 1.

Violations None

2.

Infractions a.

Failure to adhere to procedures Contrary to Technical Specification D.1., written, approved

procedures were not followed in numerous instances.

(Details

l 4.b. and 4.c.)

b.

Failure to make adequate survevs

Contrary to 10 CFR 20.201(b), the licensee failed to make evaluations adequate to comply with the provisions of

,

10 CFR 20.101, 20.103, and 20.203.

(Details 3.a, 3.b, and 4.c.)

'

3.

Deficiencies a.

Contrary to Technical Specification D.2.g(3), there is no effluent monitor in the incinerator stack.

(Details 3.c.)

B.

Deviations None

Other Significant Findings A.

Current Findings 1.

Acceptable Areas These areas were inspected on a sampling basis and fir. lings did not involve an Item of Noncompliance, Deviation, or an unresolved ites.

.

...

._.

.

- -. -

,

....

.....

...

. _.

-

.

.

.

-2-

%

a.

Instrument calibration records.

'

b.

Dasimeter calibration and leak test records.

c.

Liquid effluent release records, d.

Air effluent release records.

a.

Licensee activities conducted under Byproduct Material License No. 20-6216-1.

2.

Unresolved Items (Details 6)

a.

Licensee procedures for the use of contractor supplied health physics personnel.

b.

Licensee evaluation of air flow rates and effluent releases.

c.

Supervisory H.P. evaluation of RWP provisions.

d.

Air sample of containment prior to vapor container entry.

e.

Training proEram for healti physics personnel f.

Documentation of radiation monitor removal from incinerator stack and incinerator stack sampling provisions.

g.' Licensee evaluation of personnel exposures during steam generator

repair work, 1971.

h.

Licensee capability to perform neutron surveys, 3.

Infractions and Deficiencies Identified by the Licensee.

(Details 7)

a.

Infractions (1) Contrary to Technical Specification D.1, the procedure for release of radioactive material from the controlled area was not followed for the month of December 1974 when an environ-mental monitoring device was taken from the plant with suffi-cent radioactive contamination to subject a film badge to an exposure of 380C mrem for the period.

(2) Contrary to Technical Specification D.1, the procedure for venting control rod housings was not followed on August 6, 1974.

This failure resulted in an individual exposure to concentrations in excess of the limits set forth in 10 CFR 20, Appendix B, Table 1.

'

.

...

--.

9

%

.

-

.

.

. - _.... _.

..

..

... _ _..

-...

,

.

.

j

.

-3-i (3) Contrary en 10 CFR 20.101(a), licensee permitted an individua_ to exceed exposure limits for the third quarter of 1974. Th individual incurred a quarterly exposure of-1.290 rems prior to satisfying the requirements of Part 20 ',

,

(4) Contrary to the provisions of 10 CFR 20.103, the licensee permitted six individuals to be exposed to airborne con-centrations in excess of the provisions of 10 CFR 20.103 during the period of June 3-9, 1974. The overexposures ranged from 1.7 to 10.8 times 40 MPC hours.

The above Ilsted Items of Noncompliance were identified by the licensee and corrective action has been taken or inf tated by the licensee. In all cases. the licensee's action appears to bs appropriate and appro-priate reporting requirements were followed.

b.

Deficiencies None B.

Status of Previous Unresolved Items None

-

.

Licensee Action on Previously Identified Cnforcement Action Nons Design Changes Not Inspected Unusual Occurrences None Management Icterview

'

A management interview was conducted at the site on February 14, 1975.

Yankee Atomic Electric Company Mr. H. Autio, Plant Superintendent Mr. W. Jones, Assistant Plant Superintendent Mr. N. St.Laurent, Technical Assistant to Plant Superintendent Mr. 'd.

Billings, chemistry, H.P. Supervisor

...

_.

t

-

,

,.

A....-_...

_.:..

=-

We

. ; -

-

.

.

4_

Mr. D. Rice, T. A. to Chem., H.P. Supervisor Mr. J. Flanigan, Plant H.P.

Mr. I. Seybold, H.P. Supervisor Mr. J. MacDonald, YNSD Mr. J. Forbes, YNSD Items Discussed A.

Purpose of the inspection.

B.

Items of Noncompliance.

C.

Items of Noncompliance identified during the inspection but corrected before the conclusion of the inspection.

D.

Licensee training program.

E.

Licensee audit of October, 1974.

F.

Neutron surveys.

G.

Previously reported occurrence.

H.

Emergency kit.

I.

Iicatsee activities conducted under Byproduct Material License 20-6216-1.

J.

The inspector stated that many of the discrepancies in the licensee's radia-tion protection program could be traced to failures of management ccatrol.

The licensee representative asked what was meant by " Management Control" to which the inspector replied that management contrcl, in this context, means those systems used by management to control plant operations, for exacple, the procedures referred to in the items of noncompliance.

K.

At the conclusion of the management interview, the plant superintendent stated that a union employee had complained about the inspector questioning him during the inspection. The inspector stated that he had not called for the union employee but that he had been called by the employee representative and plant health physicist when they could not answer questions relating to the liquid effluent system. The inspector stated that he in no way attempted to antagonize or otherwise pressure the union employee and only asked very simple, forthright questions relating to valving and discharge from the effluent pumps.

...

-.

.

r

.

i

.

.

DETAILS

.

-

1.

Persons Contacted Mr. H. Autio, Plant Superintendent Mr. W. Billings, Chemistry, H.P. Supervisor

'

Mr. J. Gedutis, Chemistry Supervisor Mr. J. Flanigan, Plant H.P.

Mr. D. Rice, Environmental Monitor Mr. R. Mellor, Chemist Mr. I. Seybold, H.P. Supervisor Mr. R. Berry, T.A. for training Mr. J. Gottardi, Employee representativo, Tester Mr. H. Noga, Tester Mr. C. Brooks, Auxillary Operator Mr. B. Bouker, Chemist Mr. J. MacDonald, Radiation Protection Mancger, YAEC Mr. J. Forbes, YAEC 2.

General The inspection consisted of a review of the licensee's radiation protection program, review of selected records, procedures, plant facilities, waste storage areas, and interviews with plant personnel. During the inspection of plant tscilities, the inspector was accompanied by the employee representa-tive and the plant health physicist.

it f.

Inspectiop of Plant Facilities. Equipment, and Storage Areas, a.

The inspector made a general inspection of the plant facilities to include observation of plant components, refueling storage tanks, radioactive storage areas, waste disposal building, plant radiation areas and high radiation areas. During this inspection on February 12, 1975, the inspector observed that the licensee did not have the radioactive vaste drum storage area properly marked-off and identified in that one drum reading 20 mrem /hr at 18 inches, was near enough to the barrier rope to give a reading at the cope of 20 mrem /hr. The inspector verified that the licensee had corrected this condition prior to the conclusion of

he inspection. The inspector also identified two shipping casks outside

of the primary auxiliary building with readings of. 20-60 mrem /hr at 18 inches. These two casks were not marked or otherwise identified as having radiological significance.

The inspector verified that this condition was corrected prior to the conclusion of the inspection.

l

,.

...

.

.

I I

.

-

_.....;.. x. :,.i

.....

.

.s.:

..

Au

_.

w'

L.

-

.

,

-6-

)

b.

During the course of the inspection, the inspector identified radioactive materials in the fan room lying about on the floor reading 20-40 mrem /hr. at 18 inches. The items were wrapped in polyethylene and labled in green 91th the words, " Hot Spot" at certain points.' The items were placed in such a way that the words were ob-?";cted from view. The licensee had attempted to correct this condition prior to verification by the inspector on February 13 and 14 but had failed. The inspector observed that the licensee had failed to make such surveys as may be necessary for compliance with Part 20 and

.

that this failure resulted in a violation of 10 CFR 20.201(b).

During the inspection of the vaste disposal building and associated

c.

equipment the inspector observed that the radiaion monitor for the incinerator stack was in fact installed at the loop seal for the gas surge drum. This change in location was not inconsistent with the intent of the monitor; however, the inspector pointed out, that the Technical Specification that requires the monitor to be in the incin-erator stack should be changed. The inspector stated that this condiri n was an Item of Noncompliance with Technical Specification D.2.g(3), at.d is considered to be a deficiency. The licensee stated that this situation would be reviewed and corrected.

4.

Plant Records The inspector reviewed selected plant records using a sampling technique.

a.

The records inspected included instrument calibration records, dosi=eter calibration and leak test records, effluent release records, RWP records, plant training and indoctrination records, survey records, and personnel dosimetry and film badge records which also included environmental moni-toring film badge and TLD records. With the exception of the environmental monitoring film badge and TLD records, and RWP records, the plant records were maintained in accordance with regulatory requirements and plant procedures.

b.

The inspector's review of the environmental monitoring film badge and TLD records revealed that the film badge located at site 16 -for the period 10/1/74 to 10/31/74 was reported at 1900 mrem for the period.

The TLD report for site 17 during the same report period was read for an average of 1012 mrem.

The licensee representative responsible for environmental monitoring stated that. the contaminated film badge and the TLD vere probably located at the same site and that an error had probably been made in distribution. The licensee representative also stated that an evaluation would be made. The inspector pointed out that this situation was similar ra an incident that had been previously reported for the month of Decer5er,1974 and was a violation of plant procedures as required by Tec'.nical Specification D.1, in that a con-taminated film badge was r,e*. eased.fr.o.m the plant.

.-.

.

e

,

i

. -..

.. _

........

....

-

.. ~... ~.

. _. _ _.

-

-7-

.

c.

In reviewing records of RWP's issued during selected periods of 1974 and RWP's issued in 1975, the inspector identified numerous violations of RWP procedures and examples of inadequate radiological evaluations.

(1) The inspector identified RWP's issued in 1975 with RWP Numbers 18, 20, 23, 32, 45, and 47 that authorized work inside of primary syste=

components, where workers could encounter primary system fluid, with no evaluation as to exposure to concentrations of airborne radioactive material. The inspector stated that this failure appeared to con-stitute an Item of Noncompliance with 10 CFR 20.201(b), failure to make such surveys as necessary to comply with 10 CFR 20.103, and is considered to be an Infraction.

(2) RWP's issued in 1974 that did not comply with plant operating procedures OP 8415 or other procedures relating to RWP work as listed below:

(a) RWP 1652 and 1659 authorized workers to exceed 300 mrem / week (the administrative limit) without the specific, written authorization of the plant H.P.

(The workers did not exceed the 300 mrem / week limit.)

(b) RWP 448 required the use of a breathing zone air sampler, none was used.

.

(c) RWP 585 did not provide for continuous H.P. coverage, continuous air sampling, or a breathing zone air sample for work in coolant loope No. 1.

The RWP had been altered as to working conditions and work location (loop No. 4) apparently by someone other than the H.P. rendering the required signature.

(d) RWP 620 and 634 did not require continuous H.P. coverage, contin-uous air sampling, or a breathing zone air sample for work in coolant loop No.1 as required by operating procedure 8106.

(e) RWP 459, 466, and 501 did not require a continuous air sample for

,

work in the vaste storage building as required by operating procedure 8106.

(f) RWP 448, 498, 493 and 585 (1974) had the required physics signature rendered by a contractor supplied H.P. withcut any documentation authorizing this action.

In addition, the licensee could not produce any documentation pertaining to the training, experience, or qualifications of these contractor H.P. personnel although one licensee representative stated that he had seen resumes for these peopic.

.

...

.

-.

t

'

w...

.

._...-.s.

....

--

....

-

-., ~

.

'

,

-8-The inspector observed that most of the failures to follow the RWP procedures could probably be attributed to the fact that the RWP's were signed by personnel who were not familiar with plant procedures (contractor H.P.) and failure of management controls. This failure constitutes an item of non-compliance that '.s considered to be an infraction.

5.

Licensee activities conducted under Bvproduct Material License No. 20-6216-1 a.

The inspector reviewed the records of activities conducted under Byproduct Material License No. 20-6216-1 to include handling of sources, leak testing and inventory of sources, storage and security of sources.

b.

The inspector noted that some liquid sources were stored in glass containers on unstable surfaces in the chemistry lab. The plant chemist initiated corrective action to correct the condition.

c.

In reviewing the records of the source leak test and inventory, the inspector noted that those records maintained since June 28, 1973 appear to be complete and well maintained. The leak test and inven-tory records prior to the above mentioned date are not well maintained and are of questionable value. For example, the leak test records for May 6, 1972; November 10, 1971; and March 24, 1971 all appear to be reproduced from the same record. This is substantiated by the fact

.

54 source that that a prior date appears on one of the records and Mn was disposed of in August, 1970 was carried forward on these records.

As previously mentioned, more recent records appear to be accurate and meaningful.

'

.

6.

Unresolved Items The following tuems were discussed with the licensee during the inspection but are considered unresolved until more information is available.

a.

The licensee does not have procedures for training, other than indoctri-nations, and for assignment of responsibilities to the contractor supplied H.P. personnel, b.

The licensee does not have evaluations of air flow rates for the plant vent and other air flow rates in the plant including the chemistry " hot" hood.

i i

,.

..

-.

e

.

--

-

.

=-+ -

..uk

. -... -... -

..,;...

.

-9-

>

.

c.

There is some indication that supervisory H.P. personnel are not fully cognizant of plant radiological conditions, particularly RWP work.

d.

There is no method for sampling containment air prior to entry.

The training program for H.'r.

personnel has been submitted for e.

review and approval as' will be examined during future inspections.

f.

The licensee's safety es. Aation for moving the loop seal radiatica monitor, and sampling provisions for the incinarator stack will be reviewed during a future inspection.

g.

Further details of the licensee evaluation of personnel exposures and corrective action following steam generator repair work in 1971 will be examined at a future inspection.

h.

During discussions with the plant health physicist, the inspector learned that the licensee does not have a neutron survey instrument for plant surveys. The licensee's representatives from YAEC (Westborough) and the plant H.P. stated that a neutron survey in-

,

strument would be procured in the near future for use at the plant.

7.

Licensee R_eports The following items were reviewed by the inspector with the plant health physicisa and environ = ental monitor, as appropriate, and are considered closed.

a.

Licensee report of January 10, 1975 and February 4, 1975 regarding apparent overexposure of environmental monitoring devices, b.

Licensee report of January 29, 1975 regarding exposure to airborne concentrations in excess of the provisions of 10 CFR 20.103.

c.

Licensee report (WYR 75-3) of January 9,1975; exceeding exposure limits of 10 CFR 20.101(a),

d.

Licensee report of Septe=ber 5,1974; exceeding airborne concentrations limits.

.

...

.-.

i

-...

..

__m.-.

---


_

_

_, _

.

,

.

-

,

-10-Licensee's corrective and preventive measures for the above mentioned items appear to be appropriate and complete.

8.

Licensee Indoctrination and Training for New Emplovees and Non-Plant Personnel The inspector reviewed the H.P. indoctrination and training records for a.

10 new employees in 1974 and found two instances of records not com-pletely filled out.

b.

The inspector reviewed the indoctrination and training records for the plant shut-down of June,1974. The 1707:4; revealed that these personnel were exposed to the same plant training that new employe*s receive. There was no record to show that these contractor H.P, versonnel were trained in plant procedures'and there was no record, file or other document to indicate that these contractor H.P. personnel were adequately trained or experienced to function as H.P. for the licensee. The in-spector asked repeatedly for some documentation that might show other-wise, none was produced.

The plant superintendent indicated that he had seen resumes for thoes personnel.

9.

Licensee Emergency Kit The inspector visited the site of the emergency kit and inspected the kit for maintenance and care. The inspector observed that the kit appeared to be well =aintained and showed signs of adequate care.

.

.

...

_.

o

,

,