J Kent Dittmer ENERGY Columbia Generating Station P.O. Box 968, PE01 Richland, WA 99352-0968 NORTHWEST Ph. 509.377.4348 l F. 509.377.4150 jkdittmer@energy-northwest.com

August 26, 2021 GO2-21-107 10 CFR 50.55a

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 IN-SERVICE INSPECTION

SUMMARY

REPORT FOR THE TWENTY-FIFTH REFUELING OUTAGE (R25)

Dear Sir or Madam:

Article IWA-6000 of Section XI of the 2007 Edition with the 2008 Addenda of the American Society of Mechanical Engineers (ASME) Code requires an In-Service Inspection Summary Report be submitted to regulatory and enforcement authorities having jurisdiction at the plant site at the completion of each refueling outage for the examinations, tests, and repair replacement activities conducted since the preceding summary report.

This report is to be submitted within 90 calendar days of the completion of the refueling outage. In this case, the report is for Columbia Generating Stations (Columbia) 25th operating cycle, which ended with the start-up from refueling outage R25 on June 19, 2021.

Code Case N-532 allows Energy Northwest to prepare an Owners Activity Report Form, OAR-1, in place of the Code required NIS-1 and NIS-2 forms for the summary report. The latest revision of this code case, N-532-5, is listed in Regulatory Guide 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 19, Table 1, Acceptable Section XI Code Cases. Therefore, prior U.S. Nuclear Regulatory Commission (NRC) approval to implement this code case is not required.

The enclosure to this letter is herewith being submitted, which includes the completed OAR-1 form for Columbia. Included with the form are tables listing the Items with Flaws or Relevant Conditions that Required Evaluation for Continued Service and Abstract of Repair/Replacement Activities Required for Continued Service in accordance with Code Case N-532-5. The results that are contained in this completed form are for activities performed during cycle 25 up to and including refueling outage R25.

    

    



  

GO2-21-107 Page 2 of 2

There are no commitments being made to the NRC by this letter. By means of this submittal, the reporting requirement of IWA-6000 is fulfilled for Columbias 25th operating cycle.

Should you have any questions or require additional information, please contact Mr. R.M.

Garcia, Licensing Supervisor, at (509) 377-8463.

Executed on this _____day of ____ _______, 2021.

Respectfully,

J Kent Dittmer Vice President, Engineering

Enclosure:

Form OAR-1, Owners Activity Report for Columbia Generating Station Cycle R25

cc: NRC Region IV Administrator NRC NRR Project Manager NRC Senior Resident Inspector/988C CD Sonoda - BPA/1399 L Williamson - WA Department of L&I

    

    



  

Enclosure GO2-21-107

Form OAR-1 Owners Activity Report for Columbia Generating Station Cycle R25 DocuSign Envelope ID: F75A3185-4FC2-4977-B64F-8389F5D4AAF4

FORM OAR-1 OWNER'S ACTIVITY REPORT

Report Number ISI-SR-R25

Plant Columbia Generating Station, 76 North Power Plant Loop, Richland, WA 99354 Refueling outage Unit No. NA Commercial serv ice date 12/13/1984 no. R25 ----- -----

([ applicable)

Current inspection interval --- ----- --- ---'-4 _th _.,(1""2""/-'-1,;;;.3/""'2"'0-"1""'5_-_1~2:;.,/1""2"'/-=2,;;;.02;;;..5"")'------- - -----

( 1". 2", 3"', 4*, other)

Current inspection per iod ___ ______ _ _ _ 2_nd_ (~1_2_/1_3_/2_0_1_9_-_12_ /_1_2_/2_0_2_2~) _ _______ _ _ _

(1", 2°', 3"')

Edit ion and Addenda of Section X I applicable to the inspection plans 2007 Edition with 2008 Addenda

Date I revision of inspection plans _ _ ___________ M_ a~y _5_th_ 2 _0_2_1~, _R_e_v_is_i_o _n_7 _________ __ _

Edition and Addenda of Section X I applicable to repair/replacement activities, if different than the i nspection plans NA

Code Cases used for inspection and evaluation : _____ N_-5_ 0_8_-4_,_N_ -5_3_2_- 5__,,__, N'-'--'-6'--1--'3--2""','""'N_-6..c..c.6-'-3"-, N'-'--'-7_1--'6--1'---'N-'---"7--'4-'-7 _ __ _

(~ applicable, including cases modified by Case N-53 2 and later rev isions)

CERTIFICATE OF CONFORMANCE

I certify th at (a) th e statements made in this report are correct : (b) the ex aminations and tests, meet the Inspection Plan as required by the ASME Code,

Se c tion XI ; and (c ) the repair/ replacement activit ies an d evaluations supporting the completion of R25

Confo r m to the requirements of Sectio n XI (refueling outage number)

Signed Steve Ri bate _A_u~g_u_st_ 1_0_1h--',_2_0_2_1 __________ _ _

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid c ommission issued by the National Board of Boiler and Pressure Vessel Inspector and employed by OneCIS Insurance Company of Lynn, Massachusetts have inspected the ijems described in this Owner's Activity Report, and state that to the best of my knowledge and belief, the Owner has performed all activities rep resented by this report in accordance with the requirements of Section X L By signing this certificate ne ither the Inspector nor his employer makes any warranty, e xpressed or impl ied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspecto r nor his employee shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commission

Date 08'- I~-~

Page 1 of 2 DocuSign Envelope ID : F75A3185-4FC2-4977-B64F-8389F5D4AAF4

TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Item Description Evaluation Description Number None

TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Description of Work Date Completed Repair/Replacement Plan Number In-Core Local Power Replaced dry tube 1 Range Monitor Assembly assembly 06/14/2021 2-3151 (LPRM-DET-24/57) (Work Order 02179221)

Residual Heat Removal Repa ir indications found in 2 Heat Excha nger the upper support 05/31/2021 2-3147 attachment weld (RHR-HX-1A) (Work Order 02177380)

Date Completed refers to the date of the completed NIS-2 or NIS-2A form. The physical repair/replacement work was performed prior to June 19, 2021.

Page 2 of2