k-ENERGY Eg NORTHWEST Peop le - Vision*Solutions P.O. Box 968

  • Richland, WA
  • 99352-0968 April 27, 2006 G02-06-062 U.S. Nuclear Regulatory Commission 10 CFR 50.55a ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 CORRECTION TO THIRD TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN FOR COLUMBIA GENERATING STATION

Reference:

Letter dated December 15, 2005, WS Oxenford (Energy Northwest) to NRC, "Submittal of the Third Ten-Year Interval Inservice Inspection Program Plan and 10 CFR 50.55a Requests 31SI-01 Through 31SI-07 for Columbia Generating Station"

Dear Sir or Madam:

Pursuant to 10 CFR 50.55a(g), the referenced letter transmitted Energy Northwest's third ten-year interval Inservice Inspection (ISI) program plan for Columbia Generating Station.. During,'review of ISI examination activities for Columbia's next refueling outage, an error was fou'rid in the ISI program plan document. Specifically, the examination method detailed on tables listing code category D-A examinations on pages 5-110 and 5-111 is described as VT-3. This examination method should be described as VT-1.

The attachment hereto contains the corrected pages 5-110 and 5-111.

lf-IUfhaveany questionsbr require'additional information-regarding this-matter, please - -

contact Mr. GV Cullen,iLicensing Supervisor, at (509) 377-6105.

Respectfully, DWQColem an .. .. .; .

Manager, egulatory Programs~ ' - ; -

Mail IDrop PE20.'- '..  ; ' ':

Attachment:

Corrected pages to Third Ten-Year. Interval Inservice Inspection Program Plan cc: E;S Mallett - NRC RIV RN Sherman - BPAI1 399 EJ Benney- NRC NRR WA Horin - Winston & Strawn )4 NRC Senior Resident Inspector/988C

i .

CORRECTION TO THIRD TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN FOR COLUMBIA GENERATING STATION Attachment Corrected pages to Third Ten-Year Interval Inservice Inspection Program Plan

5.0 CODE COMPLIANCE ISI PROGRAM PLAN INTERVAL - 3 Revision 0 December 2005

[ EXAMINATION CATEGORY D-A WELDED ATTACHMENTS FOR VESSELS, PIPING. IPUMIS. AND VALVES ITEM NO. DESCRIPTION I Exam 1 Required I Deferral l Total 1 Number 1 Number l Number Number RR No./

l Method l Exams to End number l Required l 1 Perio(x 2" Period 3rd Periol l Code Case Pressure Vessels Dl.10 Welded Attachments VT-I One No 0 Vessel Piping DI.20 Welded Attachments VT-i 10% No 261 27 10 7 11 Pumps DI.30 Welded Attachments VT-I 10% No 0 Valves Dl.40 Welded Attachments VT-I 10% No 0 LIST OF CODE CATEGORY D-A EXAMINATIONS Cateeorv Item Identification No. lDescription IDrawina NoI Pg [Method I Period Outace D-A D1.20 MS-267(W) WELDED ATTACH MS-301 02 VT-I 1 18 D-A D1.20 MS-270(W) WELDED ATTACH MS-302 02 VT-I 1 18 I.

D-A D1.20 MSRV-IA-4(W) MWELDED ATTACH D-A D1.20 MSRV-3A-4(W) iWELDED ATTACH MS-301 MS-303 01 02 VT-I VT-I 1

1 18 18 I

D-A DI.20 SW-198(W) *WELDED ATTACH SW-305 01 VT-I 1 18 I D-A D-A DI.20 DI.20 SW-174(W)

SW-273(W)

WELDED ATTACH WELDED ATTACH SW-301 SW-310 01 VT-I VT-I 1

1 19 19 i

D-A Dl.20 SW-449(W) WELDED ATTACH SW-310 VT-I 1 19 Il D-A DI.20 SW-7(W) WELDED ATTACH SW-307 04 VT-I 1 19 D-A Dl.20 SW-91(W) WELDED ATTACII SW-307 03 VT- I I 9 D-A D-A D-A Dl.20 D1.20 D1.20 SW-124(W)

SW-128(W)

SW-129(W)

WELDED ATTACH WELDED ATTACH WELDED ATTACH SW-301 SW-303 SW-303 06 06 06 VT-I VT-I VT-I 2

2 2

20 20 20 i

II D-A DI.20 SW-154(W) WELDED ATTACH SW-303 01 VT-I 2 20 i 5-110

_I

5.0 CODE COMPLIANCE ISI PROGRAM PLAN

!NTER'AL- '

Revision 0 December 2(X)5 LIST OF CODE: CATEGORY D-A EXAMIINATIONS Cateeorv Item Idelitffication No. DIescription lDrawinL Nol 1' M'lethoillleri(d Outlage D-A D1.20 SW-21(W) WELDED ATTACH SW-305 VT-I 2 20 D-A D1.20 SW-35(%N) WELDED ATTACH SW-305 02 VT-I 2 20 D-A D1.20 SW-8(W) WELDED ATTACII SW-303 07 VT-I 2 20 D-A D1.20 NIS-289(W) WELDED ATTACII MS-308 02 I'T-I 3 21 D-A Dl.20 MS11-29(W) ATTACII WELD NIS-210 01 I'T-I 3 21 D-A Dl.20 MS11-30(W) ATTACH WELD NIS-210 02 VT-I 3 21 D-A Dl.20 SW-122(W) WELDED ATTACH SW-301 06 VT-I 3 21 D-A Dl.20 SW-13(W) WELDED ATTACH SW-309 VT-I 3 21 D-A Dl.20 SW-22(W) WELDED ATTACH SW-305 04 VT-I 3 21 D-A D1.20 SW-436(W) WELDED ATTACH SW-301 02 VT-I 3 21 D-A D1.20 SW-59(W) WELDED ATTACH SW-301 02 VT-I 3 21 D-A D1.20 SW-81(W) WELDED ATTACH SW-307 01 VT-I 3 21 D-A D1.20 NIS1-38(W) ,ATTACII WELD MS-214 01 VT-I 3 22 D-A DI.20 MSH-54(W) ATTACH WELD NIS-213 01 VT-1 3 22 i

i 5-111