ENS 49660
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
20:00 Dec 18, 2013 | |
| Title | Safety Function for the Hpci Suction Automatic Low Cst Level Swap Over Inoperable |
| Event Description | During the performance of surveillance testing on 12/17/2013 for the HPCI CST low water level switch instrument functional test, the safety function for the low CST level suction swap-over was lost.
While performing testing, 23LS-75B setpoint was found to be below the TS required value with 23LS-74B already declared inoperable. Tech Spec 3.3.5.1 Condition D was entered and within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of finding 23LS-75B setpoint below the TS required value, this switch was adjusted to within tolerance as allowed by procedure and tested satisfactory. Both switches were inoperable concurrently for a period of less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from time of discovery of 23LS-75B being out of tolerance. This issue has been discussed with the NRC Resident Inspector. |
| Where | |
|---|---|
| FitzPatrick New York (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| LER: | 05000333/LER-2013-006 Regarding Loss of HPCI Safety Function Due to Failure of B CST Level Switches |
| Time - Person (Reporting Time:+-1.07 h-0.0446 days <br />-0.00637 weeks <br />-0.00147 months <br />) | |
| Opened: | John Walkowiak 18:56 Dec 18, 2013 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Dec 18, 2013 |
| 49660 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
FitzPatrick | |
WEEKMONTHYEARENS 571202024-05-09T20:29:0009 May 2024 20:29:00
[Table view]10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inoperable ENS 558712022-04-29T16:51:00029 April 2022 16:51:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (HPCI) Inoperable ENS 555932021-11-18T22:02:00018 November 2021 22:02:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inoperable Due to Isolation Valve Failure to Automatically Open ENS 546572020-04-10T07:00:00010 April 2020 07:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Injection System Declared Inoperable ENS 526642017-04-04T11:35:0004 April 2017 11:35:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inadvertently Isolated During Conduct of Maintenance Surveillance ENS 516132015-12-18T22:22:00018 December 2015 22:22:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Both Trains of Containment Atmosphere Dilution System Inoperable ENS 509792015-04-12T22:00:00012 April 2015 22:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Temporary Loss of Control Room Envelope Boundary ENS 505322014-10-13T23:35:00013 October 2014 23:35:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Injection Degraded Accident Mitigation Capability ENS 502102014-06-18T19:45:00018 June 2014 19:45:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Loss of Hpci Room Cooling ENS 496602013-12-18T20:00:00018 December 2013 20:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Safety Function for the Hpci Suction Automatic Low Cst Level Swap Over Inoperable ENS 484102012-10-16T11:00:00016 October 2012 11:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Shutdown Cooling Isolation Capability Lost ENS 482702012-09-03T06:25:0003 September 2012 06:25:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable Due to Erroneous Indication on Flow Indicating Controller ENS 482582012-08-30T16:15:00030 August 2012 16:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable Due to Failed Pressure Control Valve ENS 463552010-10-23T04:45:00023 October 2010 04:45:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable Due to Power Supply Failure ENS 450082009-04-22T15:21:00022 April 2009 15:21:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (Hpci) System Inoperable ENS 429642006-11-04T23:10:0004 November 2006 23:10:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable 2024-05-09T20:29:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_49660&oldid=422606"