ENS 45008
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
15:21 Apr 22, 2009 | |
Title | High Pressure Coolant Injection (Hpci) System Inoperable |
Event Description | On 4/22/09 at approximately 1121, during surveillance testing on the High Pressure Coolant Injection (HPCI) System, the associated Primary Containment Isolation valves closed. This isolation rendered the HPCI system incapable of performing its safety function and is, therefore, reportable under 10 CFR 50.72(b)(3)(v). Technical Specification LCO 3.5.1 Condition C had been entered at 0837 to support testing. The cause of the isolation is unknown at this time. Troubleshooting is in progress. LCO 3.5.1 Condition C provides 14 days for restoration of the HPCI System, the plant will remain in the LCO until the cause is determined and any associated repairs have been completed.
A follow-up Licensee Event Report will be filed within 60 days. The NRC Resident Inspector has been notified. |
Where | |
---|---|
Fitzpatrick New York (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
LER: | 05000333/LER-2009-006 |
Time - Person (Reporting Time:+-2.3 h-0.0958 days <br />-0.0137 weeks <br />-0.00315 months <br />) | |
Opened: | Eugene Dorman 13:03 Apr 22, 2009 |
NRC Officer: | Karl Diederich |
Last Updated: | Apr 22, 2009 |
45008 - NRC Website | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (99 %) |
After | Power Operation (99 %) |
FitzPatrick with 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
WEEKMONTHYEARENS 571202024-05-09T20:29:0009 May 2024 20:29:00
[Table view]10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inoperable ENS 558712022-04-29T16:51:00029 April 2022 16:51:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (HPCI) Inoperable ENS 555932021-11-18T22:02:00018 November 2021 22:02:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inoperable Due to Isolation Valve Failure to Automatically Open ENS 546572020-04-10T07:00:00010 April 2020 07:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Injection System Declared Inoperable ENS 526642017-04-04T11:35:0004 April 2017 11:35:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection Inadvertently Isolated During Conduct of Maintenance Surveillance ENS 516132015-12-18T22:22:00018 December 2015 22:22:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Both Trains of Containment Atmosphere Dilution System Inoperable ENS 509792015-04-12T22:00:00012 April 2015 22:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Temporary Loss of Control Room Envelope Boundary ENS 505322014-10-13T23:35:00013 October 2014 23:35:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Injection Degraded Accident Mitigation Capability ENS 502102014-06-18T19:45:00018 June 2014 19:45:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Loss of Hpci Room Cooling ENS 496602013-12-18T20:00:00018 December 2013 20:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Safety Function for the Hpci Suction Automatic Low Cst Level Swap Over Inoperable ENS 484102012-10-16T11:00:00016 October 2012 11:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Shutdown Cooling Isolation Capability Lost ENS 482702012-09-03T06:25:0003 September 2012 06:25:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable Due to Erroneous Indication on Flow Indicating Controller ENS 482582012-08-30T16:15:00030 August 2012 16:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable Due to Failed Pressure Control Valve ENS 463552010-10-23T04:45:00023 October 2010 04:45:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Declared Inoperable Due to Power Supply Failure ENS 450082009-04-22T15:21:00022 April 2009 15:21:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Coolant Injection (Hpci) System Inoperable ENS 429642006-11-04T23:10:0004 November 2006 23:10:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpci Inoperable 2024-05-09T20:29:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_45008&oldid=89354"