ENS 48977
ENS Event | |
|---|---|
02:24 Apr 28, 2013 | |
| Title | Technical Specification Required Plant Shutdown |
| Event Description | This notification is being provided in accordance with 10CFR50.72(b)(2)(i), Plant Shutdown required by Technical Specifications, and 10CFR50.72(b)(3)(ii)A, Degraded or Unanalyzed Condition.
At 2245 CDT on 04/27/13, LaSalle Unit 1 commenced a Technical Specification required plant shutdown, due to identification of pressure boundary leakage. At 2124 CDT on 04/27/13, a through-wall leak was identified in the body of 1E51-F076, Reactor Core Isolation Cooling system steam supply inboard isolation bypass warmup valve. This qualifies as pressure boundary leakage, which requires entry into Technical Specification 3.4.5, Reactor Coolant System Operational Leakage, Required Action C, to be in Mode 3, Hot Shutdown, by 0924 [CDT] on 04/28/13, and Mode 4, Cold Shutdown, by 0924 [CDT] on 04/29/13. This leakage is significantly less than 10 gpm and therefore does not meet the threshold for entry into the Emergency Action Plan. At the time of discovery, Unit 1 was in startup mode following a forced outage. A unit shutdown has been initiated. A repair plan is being prepared at this time, and the unit will remain in Cold Shutdown until repairs are complete. The leak is located inside the primary containment and was visually identified during a containment walk-down. The licensee has notified the NRC Resident Inspector. |
| Where | |
|---|---|
| LaSalle Illinois (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| Time - Person (Reporting Time:+-1.6 h-0.0667 days <br />-0.00952 weeks <br />-0.00219 months <br />) | |
| Opened: | Jim Spieler 00:48 Apr 28, 2013 |
| NRC Officer: | John Shoemaker |
| Last Updated: | Apr 28, 2013 |
| 48977 - NRC Website
Loading map... | |
LaSalle | |
WEEKMONTHYEARENS 581022025-12-29T22:00:00029 December 2025 22:00:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition ENS 532762018-03-22T08:00:00022 March 2018 08:00:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Shutdown Due to Pressure Boundary Leakage ENS 513002015-08-07T18:40:0007 August 2015 18:40:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Pressure Boundary Leakage on Vent Line Welded Joint ENS 489772013-04-28T02:24:00028 April 2013 02:24:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Plant Shutdown ENS 489432013-04-18T19:00:00018 April 2013 19:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pin Holes Leaks Identified in High Pressure Core Spray System ENS 466052011-02-10T00:04:00010 February 2011 00:04:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pressure Boundary Leakage ENS 461712010-08-13T00:52:00013 August 2010 00:52:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Technical Specification Required Shutdown Due to Environmental Conditions Resulting in Elevated Ultimate Heat Sink Temperature ENS 454262009-10-12T08:33:00012 October 2009 08:33:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Technical Specification Shutdown Due to Unidentified Leakage from Rcs ENS 414872005-03-13T00:30:00013 March 2005 00:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pinhole Leak in Instrument Drain Line Off Main Steam System 2025-12-29T22:00:00 | |