ML093080006

From kanterella
Jump to navigation Jump to search
Engineering Report ER-ESP-001, Revision 2, Generic Letter 2004-02 Supplemental Response, Attachment C Through Attachment D, Page 20 of 99
ML093080006
Person / Time
Site: Comanche Peak  
Issue date: 10/13/2009
From:
Luminant Generation Co, Luminant Power
To:
Office of Nuclear Reactor Regulation
References
CP-200901403, ENR-2007-002743-20-02, GL-04-002, TXX-09128 ER-ESP-001, Rev 2
Download: ML093080006 (36)


Text

Attachment C Page 1 of 16 Comanche Peak Debris Transport Testing August 2006 ENR-2007-002743-20-02 Attachment C Page 1 of 16 Comanche Peak Debris Transport Testing August 2006 ENR-2007-002743-20-02

Attachment C Page 2 of 16 ENR-2007-002743-20-02 Attachment C Page 2 of 16 ENR-2007-002743-20-02

Attachment C Page 3 of 16 ENR-2007-002743-20-02 Attachment C Page 3 ofl6 ENR-2007-002743-20-02

Attachment C Page 4 of 16 ENR-2007-002743-20-02 Attachment C Page 4 of 16 ENR-2007-002743-20-02

Attachment C Page 5 of 16 ZUU1O-UO lesi i-iume ENR-2007-002743-20-02 Attachment C Page 5 of 16 ENR-2007-002743-20-02

Attachment C Page 6 of 16 zUUt)-U?5 i lewraps_Lamacoics ENR-2007-002743-20-02 Attachment C Page 6 of 16 ENR-2007-002743-20-02

Attachment C Page 7 of 16

]UUb-U?__ i ie_vvraps ENR-2007-002743-20-02 Attachment C Page 7 of 16 ENR-2007-002743-20-02

Attachment C Page 8 of 16 5-Ub Lamacolds ENR-2007-002743-20-02 Attachment C Page 8 of 16 ENR-2007-002743-20-02

Attachment C Page 9 of 16 2UUt--UbL-poxyUliips ENR-2007-002743-20-02 Attachment C Page 9 of 16 ENR-2007-002743-20-02

Attachment C Page 10 of 16 i-08_Paint chips ENR-2007-002743-20-02 Attachment C Page 10 of 16 ENR-2007-002743-20-02

Attachment C Page 11 of 16 ENR-2007-002743-20-02 Attachment C Page 11 of 16 ENR-2007-002743-20-02

Attachment C Page 12 of 16 Lancs Lead tianKet ENR-2007-002743-20-02 Attachment C Page 12 of 16 ENR-2007-002743-20-02

Attachment C Page 13 of 16 ZUUt-UO Leaa vvooi ENR-2007-002743-20-02 Attachment C Page 13 of 16 ENR-2007-002743-20-02

Attachment C Page 14 of 16 2UUb-U5_Lead wool tibers ENR-2007-.002743-20-02 Attachment C Page 14 of 16 ENR-2007-002743-20-02

Attachment C Page 15 of 16 ENR-2007-002743-20-02 Attachment C Page 15 of 16 ENR-2007-002743-20-02

Attachment C Page 16 of 16

--UbLaDel_ i ranspor:

ENR-2007-002743-20-02 Attachment C Page 16 of 16 ENR-2007-002743-20-02

Attachment D Page I.of 99 Comanche Peak Emergency Sump Strainer Testing March 3rd to 6th 2008 ENR-2007-002743-20-02 Attachment D i - _. _'page _L~(29 -.--;---""-.--CC~~~",,-"'-~"""'.-'

Comanche Peak Emergency Sump Strainer Testing March 3rd to 6th 2008 ENR-2007-002743-20-02

Attachment D Page 2 of 99 A

Summary

  • Test 1
  • Test 2
  • Test 3
  • Test 4 Chemi
  • Test 5
  • Test 6

- CSHL < calculated

- Fiber bypass data

- Particulate bypass data

- Maximum Debris Head Loss with cals Passed

- Thin Bed test not required

- Debris Transport Test Successful ENR-2007-002743-20-02 Attachment D

~

Page 2 of99 Summary

- Test 1 - CSHL < calculated

  • Test 2-- Fiber bypass data

-Test 3 -Particulate bypass data

- Test 4 - Maximum Debris Head Loss with Chemicals Passed

- Test 5 - Thin Bed test not required

- Test 6 - Debris Transport Test Successful ENR-2007-002743-20-02

Attachment D Page 3 of 99 Comanche Peak Test Flume built within the large steel tank Test 1 Clean Strainer Head Loss ENR-2007-002743-20-02 Attachment D Page 3 of99 Comanche Peak Test Flume built within the large steel tank Test 1 Clean Strainer Head Loss ENR-2007-002743-20-02

Attachment D Page 4 of 99 Test Module - 109.5 ft2 [approach velocity 0.0073 fps]

109.5 ft2, net scaling factor 2.9225%

ENR-2007-002743-2O-O2 Attachment D Page 4 of99 Test Module -109.5 ft2 [approach velocity 0.0073 fps]

109.5 ft2, net scaling factor 2.92250/0 ENR-2007-002743-20-02

Attachment D Page 5 of 99 Debris interceptor - 12 inches tall with 6 inch wide top 0.18 fps test vs 0.12 fps avg ENR-2007-002743-20-02 Attachment D Page 5 of99 Debris interceptor - 12 inches tall with 6 inch wide top 0.18 fps test vs 0.12 fps avg ENR -2007 -0027 4 3-20-02

Attachment D Page 6 of 99 Transport Velocity controlled by width of flume/depth of water Test 1 Clean Strainer Head Loss ENR-2007-002743-20-02 Attachment D Page 6 of99 Transport Velocity controlled by width of flume/depth of water

... 16-13/16" Test 1 Clean Strainer Head Loss ENR-2007-002743-20-02

Attachment D Page 7 of 99 Transport flume -

264 inches (22 feet)

Max flow -

0.62 fps Supplemental Strainer Testing ENR-2007-002743-20-02 Attachment D Page 70f99 Transport flume -

264 inches (22 feet)

Max flow-0.62 fps Supplemental Strainer Testing~_~~~

ENR-2007-002743-20-02

Attachment D Page 8 of 99 Transport Flume Test 1 Clean Strainer Head Loss ENR-2007-002743-20-02 Attachment D Page 8 of99 Transport Flume Test 1 Clean Strainer Head Loss-~~------.

ENR-2007-002743-20-02

Attachment D Page 9 of 99 Lead Blanket Cover Fines - 0.97 Ibm T

est 2 Fiber only ENR-2007-002743-20-02 Attachment D Page 9 of99 Lead Blanket Cover Fines - 0.97 Ibm Test 2 Fiber only ENR-2007-002743-20-02

Attachment D Page 10 of 99 LDFG (Nukon) fines - 1.6 Ibm, Min-K fiber fines - 0.025 Ibm Test 2 Fiber only ENR-2007-002743-20-02 Attachment D Page 10 of99 Nukon) fines - 1.6 Ibm, Min-K fiber fines - 0.025 Ibm Test 2 Fiber only ENR-2007-002743-20-02

Attachment D Page 11 of 99 Series 1000 Electromark labels - boiled 15 to 20 minutes Test 3 Labels ENR-2007-002743-20-02 Page 11 of99 Series 1000 Electromark labels - boiled 15 to 20 minutes Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 12 of 99 Series 1000 Electromark labels - 6x6 clear vinyl Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 12 of99 Series 1000 Electromark labels - 6x6 clear vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 13 of 99 Series 1000 Electromark labels - 6"x6" clear vinyl Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 13 of99 Series 1000 Electromark labels - 6"x6" clear vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 14 of 99 Series 1000 Electromark labels - 6"x6" white vinyl Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 14 of99 Series 1000 Electromark labels - 6"x6" white vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 15 of 99 Series 1000 Electromark labels - 6"x6" white vinyl I

Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 15 of99 Series 1000 Electromark labels - 6"x6" white vinyl Test 3 Labels ENR-2007 -002743-20-02

Attachment D Page 16 of 99 Series 1000 Electromark labels - 6"x16" white vinyl I

Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 16 of99 Series 1000 Electromark labels - 6"x16" white vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 17 of 99 Series 1000 Electromark labels - 6"x16" white vinyl I

Test 3 Labels ENR-2007-002743.-20-02 Attachment D Page 17 of99 Series 1000 Electromark labels - 6"x16" white vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 18 of 99 Series 1000 Electromark labels - 6"x16" white vinyl Test 3 Labels ENR-2007-002743-20-02 Attachment D Page 18 of99 Series 1000 Electromark labels - 6"x16" white vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 19 of 99 Series 1000 Electromark labels - 6"x16" clear vinyl I

i est 3 Labels ENR-2007-002743-20-02 Attachment D Page 19 of99 Series 1000 Electromark labels - 6"x16" clear vinyl Test 3 Labels ENR-2007-002743-20-02

Attachment D Page 20 of 99 Series 1000 Electromark labels - 6"x16" clear vinyl Test 3 Labels ENR-2007-002743-20-02 Page 20 of99 Series 1000 Electromark labels - 6"x16" clear vinyl Test 3 Labels ENR-2007-002743-20-02