Jump to search
Finding | |
---|---|
Title | Failure to Establish Adequate Procedures to Perform Maintenance on Equipment that can Affect Safety-Related Equipment |
Description | The team reviewed a self-revealing, non-cited violation of Technical Specification 5.4.1.a for the licensees failure to establish adequate procedures to properly preplan and perform maintenance that affected the performance of the B reactor protection system motor generator set. Specifically, due to inadequate procedures for troubleshooting on the B reactor protection system motor generator set, the licensee failed to identify a degraded capacitor that caused the B reactor protection system motor generator set output breaker to trip, which resulted in a reactor scram. The licensee entered this issue into their corrective action program as Condition Report CR-RBS-2014-06605 and replaced the degraded field flash card capacitor. This performance deficiency is more than minor, and therefore a finding, because it is associated with the procedure quality attribute of the Initiating Events Cornerstone and adversely affected the cornerstone objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, Exhibit 1, Initiating Event Screening Questions, this finding is determined to have a very low safety significance (Green) because the transient initiator did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would not have been available. This finding has an evaluation cross-cutting aspect within the problem identification and resolution area because the licensee failed to thoroughly evaluate this issue to ensure that the resolution addressed the cause commensurate with its safety significance. Specifically, the licensee failed to thoroughly evaluate the condition of the field flash card to ensure that the cause of the trip had been correctly identified and corrected prior to returning the B reactor protection system motor generator set to service [P.2]. |
Site: | River Bend |
---|---|
Report | IR 05000458/2015009 Section 4OA5 |
Date counted | Jun 30, 2015 (2015Q2) |
Type: | NCV: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 93812 |
Inspectors (proximate) | D Bradley J Drake T Hartman T Pruett |
Violation of: | Technical Specification |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |