Finding | |
---|---|
Title | Failure to Ensure Six Component Cooling (CC) System Manual Valves Were in the Correct Position as Required by Technical Specification (TS) Surveillance Requirement (SR) 3.7.7.1. |
Description | The inspectors identified a finding of very low safety significance (Green) and an associated NCV of Technical Specification Surveillance Requirement 3.7.7.1, for the licensees failure to ensure six component cooling (CC) system manual valves in the flow path servicing safety-related equipment, that were not locked, sealed, or otherwise secured in position, were verified in the correct position every 31 days. The licensee entered this finding into their Correction Action Program, verified the correct position of the six CC system manual valves, and revised surveillance procedures to include the requirement to periodically verify the correct position of these valves. The performance deficiency was determined to be more than minor because it was similar to IMC 0612, Appendix E, Example 3.c, since more than one valve was in the required position, but not locked, sealed, or otherwise secured in the correct position, and it impacted the Mitigating Systems cornerstones objective of ensuring the availability, reliability, and capability of systems to respond to initiating events to prevent undesirable consequences, (i.e., core damage). Since the finding did not represent an actual loss of safety function, the inspectors screened the finding as having very low safety significance (Green). The inspectors did not identify a cross-cutting aspect associated with this finding because the finding was not representative of current performance. |
Site: | Braidwood |
---|---|
Report | IR 05000456/2013007 Section 1R21 |
Date counted | Sep 30, 2013 (2013Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | B Jose C Tilton D Szwarc J Chiloyan M Munir N Valos W Sherbin |
Violation of: | Technical Specification - Procedures Technical Specification |
INPO aspect | |
' | |