Finding | |
---|---|
Title | Inadequate PBI Allowance for One EDG DOST Watertight Door Inoperable |
Description | The inspectors identified a finding of very low safety significance (Green) and an associated NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, when licensee personnel failed to recognize that when one of the two Unit 1 or Unit 2 DOST room watertight doors was impaired, the safety function of both associated safety-related EDGs was adversely impacted since the access door between the two DOST rooms was not designed to be watertight. The licensee entered this issue into their CAP as IR 1451835. Corrective actions included the creation and implementation SO 12-004 on December 18, 2012, until BwAP 1110-3 was formally revised on December 21, 2012. Both the interim SO and revision to BwAP 1110-3 required that both EDGs be considered inoperable if a flood watch was not implemented prior to the impairment of a DOST room watertight door. The finding was determined to be more than minor because it was associated with the Protection Against External Factors attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, on at least one occurrence in the past three years, the licensee had unknowingly lost the EDG safety function when performing maintenance on DOST watertight doors. The finding was determined to be of very low safety significance following a detailed risk evaluation by an NRC SRA. There was no cross-cutting aspect associated with the finding because it was not indicative of current performance. Specifically, an Engineering Change Request (ECR) that identified and evaluated this issue was completed in 1999. |
Site: | Braidwood ![]() |
---|---|
Report | IR 05000456/2012005 Section 1R06 |
Date counted | Dec 31, 2012 (2012Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.06 |
Inspectors (proximate) | M Holmberg M Perry N Feliz Adorno R Ng T Go V Meghani A Garmoe B Bartlett C Moore C Zoia D Szwarc E Duncan J Benjamin J Jandovitz J Laughlin J Robbins |
INPO aspect | |
' | |
Finding - Braidwood - IR 05000456/2012005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2012Q4
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||