05000456/FIN-2013007-05
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | |
| Description | The inspectors identified a finding of very low safety significance (Green) and associated NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to ensure abnormal operating Procedures (AOPs) 1(2)BwOA S/D-2, Shutdown LOCA, Revision 104 (105 for Unit 2) contained the necessary actions to immediately terminate Safety Injection (SI) flow if reactor coolant system (RCS) leakage was isolated. Specifically, the licensee failed to update 1(2)BwOA S/D-2, Shutdown LOCA to Revision 2 of the Westinghouse Owners Group (WOG) Abnormal Response Guideline (ARG)-2, Shutdown LOCA, that resulted in a CAUTION not added to terminate SI flow in a timely manner to prevent RCS over-pressurization, if RCS leakage was isolated. The licensee entered this finding into their Correction Action Program to add the CAUTION statement in the procedure. The finding was determined to be more than minor because it was associated with the Barrier Integrity cornerstone attribute of procedure quality and affected the cornerstones objective of providing reasonable assurance that physical design barriers protect the public from radioactive releases caused by accidents or events. Operations in accordance with the procedure may have challenged the RCS barrier during a shutdown LOCA event. Specifically, the licensee failed to update Procedure 1(2)BwOA S/D-2, Shutdown LOCA to Revision 2 of the WOG ARG-2, Shutdown LOCA guideline that resulted in a CAUTION that was not added to terminate SI flow in a timely manner to prevent RCS over-pressurization, if RCS leakage was isolated. The inspectors conducted an assessment of the risk significance of the issue in accordance with IMC 0609, Appendix G, Shutdown Operations Significance Determination Process. The inspectors determined the finding did not require a Phase II assessment and was of very low safety significance (Green). The inspectors did not identify a cross-cutting aspect associated with this finding because the finding was not representative of current performance. |
| Site: | Braidwood |
|---|---|
| Report | IR 05000456/2013007 Section 1R21 |
| Date counted | Sep 30, 2013 (2013Q3) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | B Jose C Tilton D Szwarc J Chiloyan M Munir N Valos W Sherbin |
| Violation of: | 10 CFR 50 Appendix B Criterion V |
| INPO aspect | |
| ' | |
Finding - Braidwood - IR 05000456/2013007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2013Q3
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||