| Title | Failure to Maintain Operator Response Times to Fires |
| Description | The inspectors identified a Green non-cited violation of Technical Specification 5.4.1(a), for failure to ensure that operators can respond in timely manner to safe shutdown panels in the auxiliary building with a fire in the main control room. The inspectors reviewed a condition report associated with response times of operators to a fire in the protected area with Mississippi river at flood stage. The inspectors questioned the adequacy of response times for fire brigade members and the safe shutdown operator in the event of fire in the control room with the designated operators being outside the protected area. The licensee determined a time critical task would not have been completed due to the safe shutdown operator being outside the protected area. The licensee entered this condition in the corrective action program as condition report CRGGN-2009-01416.The inspectors determined this finding to be more than minor since it affected the external events attribute of the Mitigating Systems Cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using the Manual Chapter 0609, Significance Determination Process, Phase 1 worksheet, it was determined that the finding screened as potentially risk significant due to external events and required the regional senior reactor analyst to perform a Phase 3evaluation. The senior reactor analyst determined the likelihood that control room abandonment occurs while the safe shutdown operator is out of the protected area is 9.78E-8. The change in core damage frequency is lower than this value and small enough that large early release frequency is not required to be considered. Therefore the issue is (Green) of very low safety significance. The cause of this finding has a crosscutting aspect in the area of problem identification and resolution associated with corrective action program in that the licensee failed to perform an appropriate extent of condition when implementing corrective action associated with fire brigade response issue in 2008 P.1(c) |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2009004 Section 4OA2 |
| Date counted | Sep 30, 2009 (2009Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | J Kirkland P Elkmann C Graves R Smith A Barrett G Miller C Osterholtz D Proulx M Chambers R Kellar A Fairbanks D Bollock B Rice T Pate D Reinert D Strickland R Kumana K Clayton G Guerra |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Grand Gulf - IR 05000416/2009004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2009Q3
Self-Identified List (Grand Gulf)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||