Finding | |
|---|---|
| Title | Failure to Enter a Limiting Condition for Operation for Primary Containment Isolation Valves |
| Description | The inspectors identified a Green noncited violation of Grand Gulf Nuclear Station Technical Specifications 3.6.1.3, for failure to enter a limiting condition for operation action statement for primary containment isolation valves. As a result, the limiting condition for operation action statement time was exceeded. The inspectors identified that surveillance test data for the residual heat removal Train A minimum flow valve was missing. The inspectors discovered that operations staff failed to properly review the work order for the valve work, and they had made an assumption the work order had been canceled. The licensee reviewed the identified issue for extent of condition and identified that in addition to a missed post maintenance stroke test, they had also failed to enter the limiting condition for operation for two containment isolation valves. The licensee entered this issue into the corrective action program as Condition Report CR-GGN-2009-01069.This finding was more than minor since it affects the configuration control attribute of barrier integrity cornerstone, in that failing to properly test containment isolation valves could affect the assurance that physical design barriers that protect the public from radionuclide releases caused by accidents or events. Using Manual Chapter 0609, Significance Determination Process, Phase 1 Worksheet, the finding was determined to be of very low safety significance (Green) since it did not represent an actual open pathway in the physical integrity of the containment system. The cause of this finding has a crosscutting aspect in the area of human performance associated with work practices, in that the operations shift supervisor and maintenance coordinator failed to perform proper self- and peer-checking and proper documentation of the completed work activity |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2009002 Section 1R19 |
| Date counted | Mar 31, 2009 (2009Q1) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.19 |
| Inspectors (proximate) | R Smith A Barrett G Miller B Correll |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Grand Gulf - IR 05000416/2009002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2009Q1
Self-Identified List (Grand Gulf)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||