05000416/FIN-2008004-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Perform an Adequate Risk Assessment During Adverse Weather Conditions |
Description | The inspectors identified a Green noncited violation of 10 CFR 50.65 (a)(4), involving the failure to perform risk assessments following multiple declared tornado watches affecting Grand Gulf Nuclear Station during the landfall of Hurricane Gustav. On the morning of September 3, 2008, the inspectors noted that the licensee had not evaluated the increased risk from a declared tornado watch for the Claiborne County area. The inspectors brought this to the attention of plant personnel and a risk assessment was performed and plant risk was changed from a Green to a Yellow risk condition. The inspectors then reviewed the tornado watches declared by the National Weather Service that affected Claiborne County during the landfall of Hurricane Gustav, and noted that six separate tornado watches had been declared over the previous three days. A review of the control room logs showed no documentation of changes in plant risk condition. The licensee entered this issue into the corrective action program as Condition Report CR-GGN-2008-04397. This finding is more than minor because the risk assessments failed to consider unusual external conditions that were present or imminent. Using Manual Chapter 0609, Appendix K, Maintenance Risk Assessment and Risk Management Significance Determination Process, Flowchart 1, Assessment of Risk Deficit and consulting with the regional senior risk analyst, the inspectors determined the finding of very low safety significance due to a calculated incremental core damage probability deficit of 4.38E-08. This finding has a crosscutting aspect in the area of human performance associated with work practices in that plant personnel failed to follow the risk management procedure H.4(b) |
Site: | Grand Gulf |
---|---|
Report | IR 05000416/2008004 Section 1R13 |
Date counted | Sep 30, 2008 (2008Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.13 |
Inspectors (proximate) | D Chamberlain I Anchondo G Guerra P Elkmann R Smith A Barrett E Uribe |
CCA | H.8, Procedure Adherence |
INPO aspect | WP.4 |
' | |
Finding - Grand Gulf - IR 05000416/2008004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2008Q3
Self-Identified List (Grand Gulf)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||