Finding | |
|---|---|
| Title | Failure to Monitor Performance of Four Maintenance Rule Systems |
| Description | The inspectors identified a Green noncited violation of 10 CFR 50.65(a)(2) involving the failure to adequately monitor the performance of four Maintenance Rule systems. Several discrepancies in the Maintenance Rule Program were discovered by the inspectors, including unevaluated condition monitoring failures in the neutron monitoring system and an unevaluated functional failure in the standby gas treatment system. Plant personnel implemented additional corrective actions to fully investigate the potential extent of this condition and the apparent weakness in the condition report screening process used for the Maintenance Rule program. As a result, the Maintenance Rule expert panel classified four systems as needing increased monitoring and goal setting, moving these systems from an a(2) to an a(1) status. The licensee entered this issue into the corrective action program as Condition Report CR-GGN- 2008-02219. This finding is more than minor since it was similar to Inspection Manual Chapter 0612, Appendix E, Example 7.b in that the problem involved degraded equipment performance. This finding was characterized under the significance determination process as having very low safety significance because the maintenance rule aspect of the finding did not cause an actual loss of safety function of the system nor did it cause a component to be inoperable. The cause of this finding has a crosscutting aspect in the area of human performance associated with work practices because licensee personnel failed to use proper self-checking and peer-checking to identify repetitive maintenance rule functional failures and also failed to properly document condition report screening activities H.4(a) |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2008004 Section 1R12 |
| Date counted | Sep 30, 2008 (2008Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | D Chamberlain I Anchondo G Guerra P Elkmann R Smith A Barrett E Uribe |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Grand Gulf - IR 05000416/2008004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Grand Gulf) @ 2008Q3
Self-Identified List (Grand Gulf)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||