05000390/FIN-2016011-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure To Ensure Adequate Unit 1 Emergency Diesel Generator Surveillance Instructions |
| Description | The NRC identified a Green NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures and Drawings, for the licensees failure to have adequate instructions and acceptance criteria in the emergency diesel generator surveillance instructions to ensure that the largest load rejection test bounds the power demand of the largest load. These issues were entered into the licensees corrective action program as condition reports 1201749 and 1199001. The licensee confirmed current operability and determined that likely corrective actions will include revisions to the surveillance instructions. The performance deficiency was determined to be more than minor because it was associated with the Procedure Quality attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems to respond to initiating events to prevent undesirable consequences. Specifically, the licensees SIs to implement TS SR 3.8.1.9 failed to ensure that the tested kW level of the rejected load bounded the largest predicted post-accident load. The team determined the finding to be of very low safety significance (Green) because the finding was not a design deficiency, did not represent a loss of system and/or function, and did not represent the loss of any trains of Technical Specification or Non-Technical Specification equipment. The team determined the finding was indicative of current licensee performance and assigned a cross-cutting aspect of Documentation in the area of Human Performance. |
| Site: | Watts Bar |
|---|---|
| Report | IR 05000390/2016011 Section 1R21 |
| Date counted | Sep 30, 2016 (2016Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | C Franklin C Smith H Leake J Bartley J Eargle M Greenleaf M Yeminy |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |