05000390/FIN-2016001-11
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | Watts Bar Operating License Condition 2.F requires that the licensee shall implement and maintain in effect all provisions of the approved fire protection program, as described in the Fire Protection Report for Watts Bar Unit 1, as approved in Supplements 18 and 19 of the SER (NUREG-0847). Fire Protection Report, Part V, Section 2.1, Safe Shutdown Procedures states, in part, the fire safe shutdown procedures contained in AOI-30.2 were developed based on calculations WBN-OSG4-031, Equipment Required for Safe Shutdown per 10 CFR 50 Appendix R, and WBN-OSG4-165, Manual Actions Required for Safe Shutdown Following a Fire. Calculation WBN-OSG4-165 is contained within drawing 1-45A897-1, Manual Actions Required for Safe Shutdown Following a Fire to 10 CFR 50 Appendix R. Contrary to the above, since initial plant licensing, the licensee failed to perform an adequate calculation to support fire safe shutdown procedure AOI-30.2. Specifically, for certain fire scenarios, the licensee failed to identify all equipment required to ensure availability of the TDAFW pump; and, for certain fire scenarios, the licensee established a non-conservative time requirement to mitigate spurious opening of a pressurizer PORV to prevent an undesired safety injection. This violation is of very low safety significance (Green). This issue was determined to be of very low safety significance based on the results of the IMC 0609, Appendix F, Fire Protection Significance Determination Process, Phase II Quantitative Screening Approach. A bounding risk assessment performed by a regional SRA reviewed the licensee and inspector risk evaluations and confirmed the CDF risk increase due to this condition was less than 1E-6, and therefore Green. This violation was documented in the licensees corrective action program as CRs 946764 and 999926. |
Site: | Watts Bar ![]() |
---|---|
Report | IR 05000390/2016001 Section 4OA7 |
Date counted | Mar 31, 2016 (2016Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | B Bishop C Kontz D Jones D Kern D Lanyi J Austin J Eargle J Hamman J Montgomery J Nadel R Reyes S Shah |
Violation of: | License Condition - Fire Protection License Condition |
INPO aspect | |
' | |
Finding - Watts Bar - IR 05000390/2016001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Watts Bar) @ 2016Q1
Self-Identified List (Watts Bar)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||