05000346/FIN-2010002-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Inadequate Post-Maintenance Testing of ECCS Room Cooler |
| Description | A self-revealed finding of very low safety significance and associated NCV of 10 CFR Part 50, Appendix B, Criterion XI, Test Control, was identified for the failure to adequately implement post-maintenance testing (PMT) when restoring emergency core cooling system (ECCS) room cooler 4, in ECCS train 1 pump room, to service after performing preventive maintenance. The licensee did not discover the failure of the room coolers service water inlet valve during PMT and inappropriately declared the room cooler operable after completion of testing. This condition existed until the following day, when sufficient flow was not obtained during performance testing of the cooler. As an immediate corrective action, an engineering technical evaluation determined that under current conditions, room cooler 5, the other cooler in the room, would provide sufficient heat transfer to maintain the room temperature within the bounds of design basis, thus assuring operability of ECCS train 1 equipment. Also, the work orders for the ECCS room coolers have been revised to have Operations document that the system is at normal operating pressure before performing a PMT leak check. The finding is more than minor because it is associated with the equipment reliability attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events. Specifically, the inadequate PMT did not ensure operability of ECCS room cooler 4, which also affected the operability of ECCS train 1 equipment. The inspectors determined that the finding was of very low safety significance because the inspectors answered no to all five screening questions under the mitigating systems cornerstone column. This finding has a cross-cutting aspect in the area of human performance, work practices component, because the licensee did not use appropriate human error prevention techniques. Specifically, the licensee did not properly document that the system reached normal operating pressure or temperature when performing the PMT. (H.4(a) |
| Site: | Davis Besse |
|---|---|
| Report | IR 05000346/2010002 Section 1R07 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.07 |
| Inspectors (proximate) | J Cassidy D Melendez-Colon J Rutkowski D Jones A Wilson T Go J Cameron P Voss |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Davis Besse - IR 05000346/2010002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Davis Besse) @ 2010Q1
Self-Identified List (Davis Besse)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||