Finding | |
|---|---|
| Title | Failure to Take Interim Corrective Actions to Address Structures, Systems, and Components Unprotected from Tornados |
| Description | A finding of very low safety-significance and associated Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, was identified by the inspectors for the failure to take interim corrective actions to address potential tornado missile damage to unprotected structures, systems, and components (SSCs) such as the emergency diesel generator (EDG) exhaust vent stacks. The licensee initiated a procedure change to procedure KA-EP-02810 to provide guidance for plant assessment following a tornado, and prepared an operations order to address the diesel storage tank vent lines. This violation was entered into the licensees corrective action program. The finding was determined to be more than minor because tornado missile damage to certain SSCs, such as the EDG exhaust vent stacks, could adversely affect availability, reliability, and capability of systems necessary for safe shutdown, such as the EDGs. Based on a Phase 3 analysis, the inspectors determined that the finding was of very low safety-significance because of low initiating event frequency and conservative assumptions with regards to mitigating capability. This finding has a cross-cutting aspect in the area of Problem Identification and Resolution, Corrective Action, in that, the licensee failed to thoroughly evaluate problems, such that the resolutions address causes and extent of conditions, as necessary. P.1(c) |
| Site: | Davis Besse |
|---|---|
| Report | IR 05000346/2009007 Section 1R21 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | A Boland A Shaikh B Sherbin D Mas L Jones N Valos R Langstaff S Kobylarz |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Davis Besse - IR 05000346/2009007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Davis Besse) @ 2010Q1
Self-Identified List (Davis Besse)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||