Finding | |
---|---|
Title | Failure to Implement Foreign Material Exclusion Procedure Requirements Adversely Affected the Reliability of the Main Turbine Generator and Caused a Reactor Scram |
Description | A finding of very low safety significance was self-revealed from an event that resulted in a reactor scram. The licensee failed to correctly implement its foreign materialexclusion procedure following a reactor scram on September 30, 2009. The scram was caused by a turbine trip which was caused by the presence of a very small metallic particle (foreign material) that had bored into a main generator stator bar over time and created a hole that allowed hydrogen cooling gas to leak into the stator cooling water system. The ineffective corrective actions resulted in a second reactor scram for the same cause on November 7, 2012. Because the main turbine generator is not safety-related, no violation of regulatory requirements was identified. The licensee implemented appropriate mitigation actions until a permanent corrective action involving replacement of the generator or a modification to the existing stator design can be implemented. The finding was of more than minor significance because this issue was associated with the Equipment Performance attribute of the Initiating Events Cornerstone and adversely affected the cornerstone objective of limiting the likelihood of events that upset plant stability and challenge critical safety functions during power operations. Specifically, inadequate foreign material exclusion controls coupled with a stator design that allows magnetized particles to be trapped in between the stator bars resulted in a reactor scram following development of a hydrogen leak through a stator bar. The finding was of very low safety significance because the issue: (1) did not involve a loss-of-coolant accident initiator; (2) did not cause a reactor trip AND the loss of mitigation equipment; (3) did not involve the complete or partial loss of a support system that contributes to the likelihood of, or cause, an initiating event AND affect mitigation equipment; and (4) did not increase the frequency of a fire or internal flooding initiating event. The inspector did not identify a cross-cutting aspect related to this finding. |
Site: | Fermi |
---|---|
Report | IR 05000341/2013009 Section 4OA4 |
Date counted | Jun 30, 2013 (2013Q2) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 95001 |
Inspectors (proximate) | B Kemker M Kunowski |
INPO aspect | |
' | |
Finding - Fermi - IR 05000341/2013009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fermi) @ 2013Q2
Self-Identified List (Fermi)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||