Finding | |
|---|---|
| Title | |
| Description | A self-revealed finding of very low safety significance and an associated NCV of 10 CFR 50 Appendix B,Section V, Instructions, Procedures, and Drawings, was identified for the failure to adequately prevent foreign material from entering the hydraulic control unit for control rod 10-35, which caused control rod 10-35 to fail to fully insert on October 24, 2010. Subsequently, on November 18, 2011, control rod 10-35 again failed to fully insert during scram time testing. The root cause team identified the presence of foreign organic material and concluded it had been present for a long time, i.e., at least since or prior to 2006, and this material was the cause of the deficient operation of control rod 10-35 in October 2010 and November 2011. The inspectors determined this finding was more than minor because it was associated with the configuration control attribute of the Mitigating Systems Cornerstone and impacted the cornerstone objective of ensuring the capability of systems to prevent undesirable consequences (i.e., core damage). This finding was determined to be of very low safety significance because, following IMC 0609, Appendix E, Table 4a, Characterization Worksheet for Initiating Events, Mitigating Systems, and Barrier Integrity Cornerstones, all questions were answered no. There was no cross-cutting aspect for this finding and NCV because the foreign material entered hydraulic control unit 10-35 sometime prior to 2006; and, therefore, the foreign material exclusion program inadequacies do not represent current performance. |
| Site: | Fermi |
|---|---|
| Report | IR 05000341/2012004 Section 4OA2 |
| Date counted | Dec 31, 2012 (2012Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | M Phalen J Rutkowski R Morris D Kimble R Jones J Bozga J Cameron P Smagacz T Briley |
| INPO aspect | |
| ' | |
Finding - Fermi - IR 05000341/2012004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fermi) @ 2012Q4
Self-Identified List (Fermi)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||