Finding | |
|---|---|
| Title | Untimely Corrective Actions to Resolve Seat Leakage of Containment Spray Valves 2-MV-07-3/4 |
| Description | The inspectors identified a NCV of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, for failure of the licensee to take timely and effective corrective actions to prevent seat leakage past containment spray isolation valves 2-MV-07-3 and 2-MV-07-4 resulting in long standing Reactor Coolant System (RCS) inventory perturbations while in reduced inventory operations and a long term operator workaround
The finding was more than minor in accordance with Inspection Manual Chapter (IMC) 0612, Power Reactor Inspection Reports, Appendix B, Issue Screening. Specifically, if left uncorrected the condition has the potential to become a more significant safety concern such as a loss of shutdown cooling while in mid-loop operations when the time to boil could be 15 minutes or less. Using the NRC Manual Chapter 0609, ASignificance Determination Process,@ Appendix G, Shutdown Operations Significance Determination Process, Checklist 3, the finding was determined to be of very low safety significance because Core Heat Removal, Inventory Control, Power Availability, Containment Control, and Reactivity Guidelines were all met. This finding was related to the appropriate and timely corrective actions aspect of the corrective action program (CAP) component in the problem identification and resolution crosscutting area. |
| Site: | Saint Lucie |
|---|---|
| Report | IR 05000335/2010003 Section 4OA5 |
| Date counted | Jun 30, 2010 (2010Q2) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | J Griffis G Kuzo A Vargas-Mendez T Hoeg R Carrion S Sanchez D Rich C Fletcher |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |