Finding | |
---|---|
Title | Failure to promptly correct a condition adverse to quality associated with degraded intake cooling water pump discharge check valves |
Description | The NRC identified a Green Non-cited Violation of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to promptly correct a condition adverse to quality that being degraded check valves on the intake cooling water system affecting both units. The failure to implement corrective actions after identifying that the valves were degraded in an inspection in 2005 resulted in a reduction in system reliability and a burden to plant operators. The issue was documented in the corrective action program as CR 2010-7380, and the license intends to replace the check valves at the next availability. The finding was more than minor because it is associated with the Equipment Performance attribute of the Mitigating Systems Cornerstone in that it adversely affected the reliability of the intake cooling system to respond to initiating events to prevent undesirable consequences. The finding was screened using Manual Chapter 0609.04, Phase 1 Initial Screening and Characterization of Findings, and was determined to have a very low safety significance (Green) because the system remained operable and capable of meeting its design function with no loss of safety function of any train of intake cooling water. The cross-cutting aspect of H.3 (b) was applicable because the licensee did not plan work activities to support long term equipment reliability to limit operator workarounds and reliance on manual actions. |
Site: | Saint Lucie |
---|---|
Report | IR 05000335/2010006 Section 4OA2 |
Date counted | Mar 31, 2010 (2010Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | G Hopper R Taylor M King T Hoeg J Hamman J Stewart |
CCA | H.5, Work Management |
INPO aspect | WP.1 |
' | |
Finding - Saint Lucie - IR 05000335/2010006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Saint Lucie) @ 2010Q1
Self-Identified List (Saint Lucie)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||