Finding | |
---|---|
Title | Failure to Promptly Correct a Condition Adverse to Quality Involving Motor Control Center Bus Stabs |
Description | The inspectors reviewed a self-revealing violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the failure to correct conditions adverse to quality. Specifically, the licensee failed to promptly replace short bus stabs with longer bus stabs in six 480V safety-related motor control centers as planned following a 2007 motor control center fault. Subsequently, safety-related motor control centers remained susceptible to a fault because corrective actions had not been implemented. This issue was entered into the licensees corrective action program as Condition Report 2015-2661. The licensee has completed the modifications to all breakers except those requiring an outage. The failure to promptly correct conditions adverse to quality associated with 480V breaker connections to bus bars was a performance deficiency. The performance deficiency is more than minor because it is associated with the equipment performance attribute of Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events. Specifically, untimely corrective actions allowed an increased likelihood of a fault to continue to exist that would result in the loss of the associated safety-related motor control centers if the fault occurred. Using NRC Inspection Manual Chapter 0609 Appendix A, Significance Determination Process (SDP) for Findings At-Power, the inspectors determined that the finding was of very low safety significance (Green) because the finding was not a deficiency affecting design or qualification, did not represent a loss of system and/or function, and did not represent an actual loss of function. This finding was not assigned a cross-cutting aspect because it was not indicative of current plant performance; the licensee decided to remove the corrective actions from the corrective action program more than 3 years ago. |
Site: | Arkansas Nuclear |
---|---|
Report | IR 05000313/2015003 Section 4OA2 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | A Barrett B Correll B Tindell J Dixon M Williams N O'Keefe R Egli T Farina Z Hollcraft M Tobin |
Violation of: | 10 CFR 50 Appendix B Criterion XVI |
INPO aspect | |
' | |
Finding - Arkansas Nuclear - IR 05000313/2015003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Arkansas Nuclear) @ 2015Q3
Self-Identified List (Arkansas Nuclear)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||