05000266/FIN-2010004-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | |
| Description | A finding of very low safety significance and associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, was identified by the inspectors for the failure to ensure that the residual heat removal (RHR) system would be capable of responding to a loss of coolant accident that occurred in Mode 4. Specifically, the RHR system could experience flash evaporation during a loss of coolant accident in this Mode resulting in steam binding of the system pumps and/or an adverse waterhammer. The licensee entered this issue into the corrective action program and will make procedure changes to ensure the operability of at least one RHR train while in Mode 4. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems Cornerstone attribute of equipment performance and affected the cornerstone objective of ensuring the capability of systems that respond to initiating events to prevent undesirable consequences. The finding screened as very low safety significance because a Phase II evaluation determined that it represented a change in core damage frequency of less than 5 E-9. The inspectors determined that this finding did not have a cross-cutting aspect because it was not obvious that the licensee should have identified the potential problem with RHR. |
| Site: | Point Beach |
|---|---|
| Report | IR 05000266/2010004 Section 4OA5 |
| Date counted | Sep 30, 2010 (2010Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | N Feliz-Adomo W Lyon P Cardona-Morales D Cunanan D Woodyatt R Langstaff R Ruiz J Jandovitz M Phalen M Kunowski S Burton |
| INPO aspect | |
| ' | |
Finding - Point Beach - IR 05000266/2010004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Point Beach) @ 2010Q3
Self-Identified List (Point Beach)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||