05000266/FIN-2010002-06
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Establish Required Fire Watches |
| Description | A finding of very low safety significance and associated Non-Cited Violation of Technical Specification 5.4.1.h for Units 1 and 2 was identified by the inspectors for the licensees failure to establish appropriate fire watches required as compensatory measures to address identified fire protection impairments. Specifically, on three occasions, the licensee failed to issue, and properly implement, fire watch surveillances as required by procedure OM 3.27. The licensee had entered all instances into its corrective action program. The finding was more than minor because the finding was associated with the Mitigating Systems Cornerstone attribute of protection against external factors (fire) and affected the cornerstone objective of ensuring the availability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to implement fire watches required as compensatory measures degraded the defense-in-depth elements of the fire protection program that is necessary to ensure safe shutdown in the event of a fire. The issue was of very low safety significance based on the low degradation rating for the finding. The finding had a cross-cutting aspect in the area of human performance, resources, because the licensees preliminary apparent cause evaluation attributed the underlying cause of these events to less than adequate procedures, or procedures that did not adequately link to each other, and pre-job briefing materials that did not address fire protection considerations (H.2(c)). |
| Site: | Point Beach |
|---|---|
| Report | IR 05000266/2010002 Section 4OA2 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Dahbur J Bozga J Gilliam J Jandovitz M Kunowski M Phalen M Thorpe Kavanaugh N Feliz Adorno P Cardona Morales R Edwards R Ruiz R Winter S Burton T Bilik |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Point Beach - IR 05000266/2010002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Point Beach) @ 2010Q1
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||