i OYSTER CREEK NUCLEAR GENERATING STATION o
emwe c. ~.,].v.ad%
(609)693-6000 P O BOX 388
.J, Der 23, 1981
?
Mr. Ronald Haynes, Directer RECEIVED Office of Inspection and Enforcanent f
Region I C
JAN I 31982> 4-United States Nuclear Regulatory Ommission a mim rwIDTcuculs 631 Park Avenue 9
" kW "
7 King of Prussia, Pennsylvania 19406 4 M r0
Dear Mr. Haynes:
. W SUBJECT: Oyster Creek Nuclear Generating Station Docket No. 50-219 Licensee Event Report Reportable Occurrence No. 50-219/81-65/0lT This letter forwards three copies of a Licensee Event Report to report Peportable Occurrence No. 50-219/81-65/0lT in empliance with paragraphs 6.9.2.,a,9 and 6.9.2.,b,2 of the 'Ibchnical Specifications.
Very truly yours,
/
4W
. T. Carroll, Jr Acting Director ter Creek JTC:dh Enclosures cc: Director (40 copies)
Office of Inspmtion and Enforcement United States Nuclear Regulatory Q2mtission Washington, D.C.
20555 Director (3)
Office of Managanent Information and Program Control United States Nuclear Regulatory Ommission Washington, D. C. 20555 8201150279 811223 PDR ADOCK 05000219 NRC Resident Inspector (1)
S PDR Oyster Creek Nuclear Generating Station d
f Si (
Forked River, N. J.
,I OYSTER CREEK NUCLEAR GENERATING STATICN Ebrked River, New Jersey 08731 Licenseo Event Tuport Reportable Occurrence No. 50-219/81-65-OlT Report Date December 23, 1981 Occurrence Date Decenber 9,1981 Identification of Occurrence Limitorque operators and isolation valves for the Isolation Conde.aser Systen were found to have defects whidi did affect the operability of one valve and could affect those m other systems which perform a reactor coolant pressure boundary and prinary containment isolation function.
This is considered to be a reportable occurrence in accordance with Section 6.9.2.,a,9 of the Oyster Creek Technical Specifications.
Additionally, valve V-14-30 in the Isolation Condenser Systen was found to be inoperable, and failed to fully close when subjected to a close signal. This is determined to be operation in a degraded mode permitted by Section 3.8.C and Table 3.1.1,H.
This is considered to be a reportable occurrence in accordance with Section 6.9.2.,b,2 of the Oyster Creek Technical Specifications.
Conditions Prior to Occurrence Power:
Reactor 1844 Mit Generator 645 W e 4
Flow:
Eecirculation 15.6 x 10 99" 6
f Feedwater 7.06 x 10 lb/hr Description of Occurrence On Thursday, Decater 3,1981, during a surveillance test, the "A" isolation condensers' isolation valve V-14-30 failed to properly cperate fully in the closed direction until the third stroke attetpt. The valve was successfully cycled two more times and at the time it was suspected there was a problem with the torque switches. A rcaintenance job order was issued to inspect the switches.
On December 4, after discussions with the NBC Recident Inspector, who questioned the operability / reliability of V-14-30 (based on previous night's testing), a decision was made to stroke the valve to daronstrate operability.
. _ - - -. - - ~ - -,. - - -- -
Ecportable Occurrence Page 2 Report No. 50-219/81-65/0lT On Decmber 4, V-14-30 was again stroked and failed to fully close. 'Ihe "A" isolation condenser was declared inoperable and the "B" isolation mndensers' isolation valves were successfully operated in accordance with the plant's technical specification requirments. 'Ihe limitorque operator for valve V-14-30 was inspected, and the lower 11/2 threads of the stm nut were fourx1 to be damaged. The damaged threads were machined and on Sunday, Decmber 6,1981, at approximately 1830, the "A" isolation condenrer was detennined operable after a successful isolation valve operability test.
On Decmber 7, in a subsequent action to determine the possibility of a generic actuator problem, the "B" isolation condenser, which was in need of packing repair on Valve V-14-32, was restoved frmt service. The stm nut on V-14-32 was inspected and found to have three damaged lower threads and also showed indica-tions of radial cracking, approximately two inches in length up the stm nut.
In a further effort to investigate a possible generic problm, a reactor shutdown was cntmenced on Wednesday, December 9, at approximately 1809, in order to cmplete further limitorque operator inspections. As a result of internal inspections of valve V-14-32, crack indications have been discoverd on the stm in the area of the stem backseat.
Apparent cause of Oc.mrrence It has been determined that the multiple nu:tber of backseating operations performed over the life of the plant in addition to the stresses induced by the thermal cycling of the valves while in the backseated position caused valve damage. After disassmbly of valve V-14-32 (steam inlet to the "B' isolation
~
condenser) it was determined the stm backseat had been severely damaged enabling the st m to travel a distance further than designed. This resulted in damage to the limitorque operator stem nut by engagem2nt of the unthreaded portion of the valve st m into the st m nut.
During the backseating process the limit switch and torque switch are bypassed l
to allow the full motor torque to be used to backseat the valve. This operation is performed at the circuit breaker by electrical personnel while fronitoring the motor amperage for protection of the motor. When a sudden rise in amperage is observed the notor is deenergized and the valve is left in this position until the next required valve operability test.
l Analysis of Occurrence i
l
'Ihe purpose of the isolation condensers are to depressurize the reactor and ta reove reactor decay heat in the event that the main condenser is unavailable as a heat sink. The isolation condensers' inlets and outlets are equipped with l
double isolation valves (A.C. and D.C.) that will automatically close on high l
steam or high condensate flow which is indicative of a pipe break. Failure of l
these valves to close would result in degradation of the reactor coolant pressure boundarf.
1 1
L _
Reportable Orarrence Page 3 Report No. 50-219/81-65/0lT The identified failures have the potential of preventing a safety systm frm cperating, causing a degradation in those systms providcxl to contain fission products, and/or creatiny a situation lmehng to high primary coolant systm leakage
Corrective Action
After V-14-30 failed to fully close, the valve operator was taken apart and inspected. Dannged threads in the lower part of the stan nut were repaired and the valve was pla d back into service.
In a subsequent effort to determLne the possibility of a generic actuator problan, the "B" isolaticn condenser was raroved fran service in order to inspect isolation valve V-14-32.
Since the atm. nut for V-14-32 showcx1 indications of thread damage and cracking, the reactor was shutdown and cooled down to less than 212 F.
The suspect isolation valve operators are being inspected for evidence of stan nut danuge. Furthermore, valve inspections are being perfonned on valves wirse sten nut exhibits the characteristics of valve stan over-extension. 'Ihe results of continuinJ inspection and further corrective action will be described in a supplanental report.
Station operating procedures will be reviewed and rnodified such that safety systan isolation valves will be backseated in an approved manner.
Failure Data 10 inch Anchor Gate Valve Limitorque Operator Type SMB-2 i
f
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000219/LER-1981-001-03, /03L-0:on 810102,containment Spray Sys High Drywell Pressure Indicating Switch IP-15C Tripped Above Tech Spec Limits.Caused by Instrument Repeatability.Switch Reset & Study Examining Causes of Repeatability Undertaken | /03L-0:on 810102,containment Spray Sys High Drywell Pressure Indicating Switch IP-15C Tripped Above Tech Spec Limits.Caused by Instrument Repeatability.Switch Reset & Study Examining Causes of Repeatability Undertaken | | | 05000219/LER-1981-001, Forwards LER 81-001/03L-0 | Forwards LER 81-001/03L-0 | | | 05000219/LER-1981-002, Forwards LER 81-002/03L-0 | Forwards LER 81-002/03L-0 | | | 05000219/LER-1981-002-03, /03L-0:on 810102,gaseous Releases to Stack Found Not Continuously Monitored as Required by Tech Spec.Caused by Tripping of Stack Gas Sample Pump Due to Normal Wear.Pump Replaced W/Spare | /03L-0:on 810102,gaseous Releases to Stack Found Not Continuously Monitored as Required by Tech Spec.Caused by Tripping of Stack Gas Sample Pump Due to Normal Wear.Pump Replaced W/Spare | | | 05000219/LER-1981-003-03, /03L-0:on 810112,during Visual Insp of Fire Hydrants,Hydrant 2 Found to Contain Frozen Water in Barrel, Rendering Hydrant Inoperable.Caused by Water Leaking from Hydrant Valve & Freezing in Barrel.Hydrant Thawed | /03L-0:on 810112,during Visual Insp of Fire Hydrants,Hydrant 2 Found to Contain Frozen Water in Barrel, Rendering Hydrant Inoperable.Caused by Water Leaking from Hydrant Valve & Freezing in Barrel.Hydrant Thawed | | | 05000219/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | | | 05000219/LER-1981-004, Forwards LER 81-004/01T-0 | Forwards LER 81-004/01T-0 | | | 05000219/LER-1981-004-01, /01T-0:on 810116,studies Indicated That Emergency Diesel Generators May Exceed Load Rating During Accident Conditions.Caused by Using Different & More Conservative Methods to Calculate Load.Actions to Reduce Load Underway | /01T-0:on 810116,studies Indicated That Emergency Diesel Generators May Exceed Load Rating During Accident Conditions.Caused by Using Different & More Conservative Methods to Calculate Load.Actions to Reduce Load Underway | | | 05000219/LER-1981-005-03, /03L-0:on 810106,emergency Svc Water Pump 52B Current & Discharge Pressure Found Outside Tech Spec. Probably Caused by Clogged Pump Suction Strainer.Strainer Cleared | /03L-0:on 810106,emergency Svc Water Pump 52B Current & Discharge Pressure Found Outside Tech Spec. Probably Caused by Clogged Pump Suction Strainer.Strainer Cleared | | | 05000219/LER-1981-005, Forwards LER 81-005/03L-0 | Forwards LER 81-005/03L-0 | | | 05000219/LER-1981-006-03, /03L-0:on 810115,during Surveillance Testing, Reactor Triple Low Water Level Indicator Switch RE-18B Tripped at Monometer Reading Higher than Allowed by Tech Spec Table 3.1.1.Caused by Instrument Drift.Switch Reset | /03L-0:on 810115,during Surveillance Testing, Reactor Triple Low Water Level Indicator Switch RE-18B Tripped at Monometer Reading Higher than Allowed by Tech Spec Table 3.1.1.Caused by Instrument Drift.Switch Reset | | | 05000219/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | | | 05000219/LER-1981-007-03, /03L-0:on 810202,water-tight Door to Containment Spray Sys I Compartment Not Closed & Verification of Closed Door Not Performed.Caused by Personnel Error & Lack of Controls to Ensure Doors Are Closed After Passage | /03L-0:on 810202,water-tight Door to Containment Spray Sys I Compartment Not Closed & Verification of Closed Door Not Performed.Caused by Personnel Error & Lack of Controls to Ensure Doors Are Closed After Passage | | | 05000219/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | | | 05000219/LER-1981-008, Forwards LER 81-008/03L-0 | Forwards LER 81-008/03L-0 | | | 05000219/LER-1981-008-03, /03L-0:on 810210,water Seepage Observed Along West Wall of Nrw Bldg.Direct Survey Showed Detectable Ground Contamination Only within 6 Inches of Wall.Caused by High Levels in Tank Vaults.Herculite Secured & Sealed to Wall | /03L-0:on 810210,water Seepage Observed Along West Wall of Nrw Bldg.Direct Survey Showed Detectable Ground Contamination Only within 6 Inches of Wall.Caused by High Levels in Tank Vaults.Herculite Secured & Sealed to Wall | | | 05000219/LER-1981-009, Forwards LER 81-009/03L-0.Detailed Event Analysis Submitted | Forwards LER 81-009/03L-0.Detailed Event Analysis Submitted | | | 05000219/LER-1981-009-03, /03L-0:on 810213,snubber 23/3 Found W/Very Low Oil Level & Oil Discovered on Floor at Base Connection During NRC walk-around Insp.Caused by Failure of Inner Shaft Seal Due to Deterioration.Snubber Replaced W/Operable Spare | /03L-0:on 810213,snubber 23/3 Found W/Very Low Oil Level & Oil Discovered on Floor at Base Connection During NRC walk-around Insp.Caused by Failure of Inner Shaft Seal Due to Deterioration.Snubber Replaced W/Operable Spare | | | 05000219/LER-1981-010, Forwards LER 81-010/03L-0 | Forwards LER 81-010/03L-0 | | | 05000219/LER-1981-010-03, /03L-0:on 810202,during Routine Surveillance Testing,Main Steamline High Radiation Monitor RN-06B Tripped at Value Higher That Tech Spec Limits.Caused by Failure to Revise Trip Settings.Trip Settings Lowered | /03L-0:on 810202,during Routine Surveillance Testing,Main Steamline High Radiation Monitor RN-06B Tripped at Value Higher That Tech Spec Limits.Caused by Failure to Revise Trip Settings.Trip Settings Lowered | | | 05000219/LER-1981-011, Forwards LER 81-011/03L-0.Detailed Event Analysis Encl | Forwards LER 81-011/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-011-03, /03L-0:on 810309,isolation Condenser Condensate Return Line Pipe Break Sensor IB11B2 Found to Trip at Value Greater than That Specified in Tech Specs.Caused by Instrument Repeatability.Replacement Recommended | /03L-0:on 810309,isolation Condenser Condensate Return Line Pipe Break Sensor IB11B2 Found to Trip at Value Greater than That Specified in Tech Specs.Caused by Instrument Repeatability.Replacement Recommended | | | 05000219/LER-1981-012-03, /03L-0:on 810313,electromatic Relief Valve High Pressure Actuation Switches 1A83C & 1A83E Tripped Higher than Limit Specified in Tech Spec.Caused by Instrument Repeatability.Pressure Sensors Reset to Trip within Limits | /03L-0:on 810313,electromatic Relief Valve High Pressure Actuation Switches 1A83C & 1A83E Tripped Higher than Limit Specified in Tech Spec.Caused by Instrument Repeatability.Pressure Sensors Reset to Trip within Limits | | | 05000219/LER-1981-012, Forwards LER 81-012/03L-0.Detailed Event Analysis Encl | Forwards LER 81-012/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-013-03, /03L-0:on 810319,core Spray Hi Drywell Pressure Switch RV46B Tripped in Excess of 2 Psi Tech Spec.Caused by Sensor Repeatability.Sensor Recalibr.Replacement of Sensors Recommended by PORC | /03L-0:on 810319,core Spray Hi Drywell Pressure Switch RV46B Tripped in Excess of 2 Psi Tech Spec.Caused by Sensor Repeatability.Sensor Recalibr.Replacement of Sensors Recommended by PORC | | | 05000219/LER-1981-013, Forwards LER 81-013/03L-0.Detailed Event Analysis Encl | Forwards LER 81-013/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-014, Forwards LER 81-014/01T-0.Detailed Event Analysis Encl | Forwards LER 81-014/01T-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-014-01, /01T-0:on 810401,containment Oxygen Concentration Was Not Reduced to Less than 5% within 24-h After Placing Reactor Mode Switch in Run.Caused by Inerting at Significantly Reduced Rates | /01T-0:on 810401,containment Oxygen Concentration Was Not Reduced to Less than 5% within 24-h After Placing Reactor Mode Switch in Run.Caused by Inerting at Significantly Reduced Rates | | | 05000219/LER-1981-015-03, /03L-0:on 810324,main Steam Line High Flow Sensors Tripped at Values Greater than Tech Specs Limit.Caused by Instrument Repeatability.Both Sensors Reset | /03L-0:on 810324,main Steam Line High Flow Sensors Tripped at Values Greater than Tech Specs Limit.Caused by Instrument Repeatability.Both Sensors Reset | | | 05000219/LER-1981-015, Forwards LER 81-015/03L-0.Detailed Event Analysis Encl | Forwards LER 81-015/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-016-03, /03L-0:on 810421,approx 10,000 Gallons of Leakage from Condensate Transfer Pump Bldg Was Discovered on North & South Sides of Bldg.Caused by Loss of Valve Packing on V-2-88.Leakage Was Diked & Valve Repacked | /03L-0:on 810421,approx 10,000 Gallons of Leakage from Condensate Transfer Pump Bldg Was Discovered on North & South Sides of Bldg.Caused by Loss of Valve Packing on V-2-88.Leakage Was Diked & Valve Repacked | | | 05000219/LER-1981-016, Forwards LER 81-016/03L-0 | Forwards LER 81-016/03L-0 | | | 05000219/LER-1981-017, Forwards LER 81-017/03L-0.Detailed Event Analysis Encl | Forwards LER 81-017/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-017-03, /03L-0:on 810415,one Containment Spray Sys Loop Considered Inoperable During Normal Operation.Caused by Large Amount of Sea Lettuce in Intake Canal,Overwhelming Trash Removal Sys.Circulating Water Pump Stopped | /03L-0:on 810415,one Containment Spray Sys Loop Considered Inoperable During Normal Operation.Caused by Large Amount of Sea Lettuce in Intake Canal,Overwhelming Trash Removal Sys.Circulating Water Pump Stopped | | | 05000219/LER-1981-018, Forwards LER 81-018/01T-0.Detailed Event Analysis Encl | Forwards LER 81-018/01T-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-018-01, /01T-0:on 810417,equipment Operator Found Valves Were Blocked from Fully Opening by Scaffolding Placed by Contractor Personnel.Caused by Personnel Error.Scaffolding Repositioned | /01T-0:on 810417,equipment Operator Found Valves Were Blocked from Fully Opening by Scaffolding Placed by Contractor Personnel.Caused by Personnel Error.Scaffolding Repositioned | | | 05000219/LER-1981-019-03, /03L-0:on 810328,during Normal Shutdown Sequence, IRM Calibr Was Not Performed as Required by Tech Specs. Caused by Procedural Inadequacy.Procedures Will Be Revised | /03L-0:on 810328,during Normal Shutdown Sequence, IRM Calibr Was Not Performed as Required by Tech Specs. Caused by Procedural Inadequacy.Procedures Will Be Revised | | | 05000219/LER-1981-019, Forwards LER 81-019/03L-0 | Forwards LER 81-019/03L-0 | | | 05000219/LER-1981-020-03, /03L-0:on 810501,isolation Condenser Shell Level Instrument IGO6B Found Reading High During Annual Calibr. Caused by Evaporation of Instrument Ref Column.Column Backfilled W/Water to Normal Operating Level | /03L-0:on 810501,isolation Condenser Shell Level Instrument IGO6B Found Reading High During Annual Calibr. Caused by Evaporation of Instrument Ref Column.Column Backfilled W/Water to Normal Operating Level | | | 05000219/LER-1981-020, Forwards LER 81-020/03L-0.Detailed Event Analysis Encl | Forwards LER 81-020/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-021, Forwards LER 81-021/03L-0.Detailed Event Analysis Encl | Forwards LER 81-021/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-021-03, /03L-0:on 810603,high Pressure Sensor Switches RE03B, C & D Were Found Tripping within 8 Lb of Setpoint. Caused by Sensor Repeatability.Switches Reset.Switches Will Be Replaced During Next Refueling Outage | /03L-0:on 810603,high Pressure Sensor Switches RE03B, C & D Were Found Tripping within 8 Lb of Setpoint. Caused by Sensor Repeatability.Switches Reset.Switches Will Be Replaced During Next Refueling Outage | | | 05000219/LER-1981-022-01, /01T-0:on 810520,secondary Containment Integrity Not Maintained Due to Personnel Access Airlock Doors Ajar. Caused by Personnel Error & Loosened Striker Plate on Inside Door.Outside Door Closed & Striker Plate Repaired | /01T-0:on 810520,secondary Containment Integrity Not Maintained Due to Personnel Access Airlock Doors Ajar. Caused by Personnel Error & Loosened Striker Plate on Inside Door.Outside Door Closed & Striker Plate Repaired | | | 05000219/LER-1981-022, Forwards LER 81-022/01T-0 | Forwards LER 81-022/01T-0 | | | 05000219/LER-1981-023-03, /03L-0:on 810603,drywell Vented to Reduce Drywell Torus Differential Pressure.Caused by Moisture Buildup in Sensing Line Resulting in Erroneous Indication of Increased Oxygen Concentration.Procedures Will Be Reviewed | /03L-0:on 810603,drywell Vented to Reduce Drywell Torus Differential Pressure.Caused by Moisture Buildup in Sensing Line Resulting in Erroneous Indication of Increased Oxygen Concentration.Procedures Will Be Reviewed | | | 05000219/LER-1981-023, Forwards LER 81-023/03L-0.Detailed Event Analysis Encl | Forwards LER 81-023/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-024-03, /03L-0:on 810608,while Operating in Degraded Mode, Two Emergency Water Pumps Found Inoperable.Caused by Faulty Ammeter,Clogged Pump Suction Bells & Inadequate Administrative Controls.Ammeter Replaced & Bells Cleaned | /03L-0:on 810608,while Operating in Degraded Mode, Two Emergency Water Pumps Found Inoperable.Caused by Faulty Ammeter,Clogged Pump Suction Bells & Inadequate Administrative Controls.Ammeter Replaced & Bells Cleaned | | | 05000219/LER-1981-024, Forwards LER 81-024/03L-0.Detailed Event Analysis Encl | Forwards LER 81-024/03L-0.Detailed Event Analysis Encl | | | 05000219/LER-1981-025-01, /01T-0:on 810617,secondary Containment Was Broken When Both Reactor Bldg Railroad Airlock Doors Were Opened Together.Caused by Failure of Top Inner Door Latch & Operator Error.Operators Will Be Reinstructed | /01T-0:on 810617,secondary Containment Was Broken When Both Reactor Bldg Railroad Airlock Doors Were Opened Together.Caused by Failure of Top Inner Door Latch & Operator Error.Operators Will Be Reinstructed | | | 05000219/LER-1981-025, Forwards LER 81-025/01T-0.Detailed Event Analysis Encl | Forwards LER 81-025/01T-0.Detailed Event Analysis Encl | |
|