 Issue dateTitleTopic
05000391/LER-2017-00525 January 2018Unplanned Emergency Core Cooling System Injection into the Reactor Coolant System due to Personnel Error
LER 17-005-00 for Watts Bar, Unit 2, Regarding Unplanned Emergency Core Cooling System Injection into the Reactor Coolant System due to Personnel Error
Safe Shutdown
05000390/LER-2017-0158 January 2018Failure to Enter Limiting Condition of Operation Action Statement Results in a Condition Prohibited by Technical Specifications
LER 17-015-00 for Watts Bar, Units 1 and 2, Regarding Failure to Enter Limiting Condition of Operation Action Statement Results in a Condition Prohibited by Technical Specifications
Safe Shutdown
05000390/LER-2017-01420 December 2017Main Control Room Boundary Door Left Open Leading to a Loss of Safety Function
LER 17-014-00 for Watts Bar, Unit 1, Regarding Main Control Room Boundary Door Left Open Leading to a Loss of Safety Function
Safe Shutdown
Probabilistic Risk Assessment
05000390/LER-2017-01223 October 2017Error in Plant Emergency Procedures Leads to a Condition Prohibited by the Technical Specifications
LER 17-012-00 for Watts Bar, Unit 1, Regarding Error in Plant Emergency Procedures Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
Past operability
Probabilistic Risk Assessment
05000390/LER-2017-01123 October 2017Failure to Enter Technical Specification 3.6.3 for Containment Isolation Valve
LER 17-011-00 for Watts Bar, Unit 1, Regarding Failure to Enter Technical Specification 3.6.3 for Containment lsolation Valve
Safe Shutdown
Time of Discovery
05000390/LER-2017-01010 October 2017Actuation of Turbine Driven Auxiliary Feedwater Pump Due to Loss of 6.9kV Shutdown Board
LER 17-010-00 for Watts Bar Nuclear Plant, Unit 1 Regarding Actuation of Turbine Driven Auxiliary Feedwater Pump Due to Loss of 6.9kV Shutdown Board
Safe Shutdown
05000391/LER-2017-00425 September 2017Manual Reactor Trip Due to Inoperable Rod Position Indication
LER 17-004-00 for Watts Bar Nuclear Plant, Unit 2 Regarding Manual Reactor Trip Due to Inoperable Rod Position Indication
Safe Shutdown
Anticipated operational occurrence
05000390/LER-2017-00431 August 2017Manual Reactor Trips Due to Failed Reactor Coolant Pump Power Transfer During Plant Startup
LER 17-004-01 for Watts Bar, Unit 1, Regarding Manual Reactor Trips Due to Failed Reactor Coolant Pump Power Transfer During Plant Startup
Safe Shutdown
Anticipated operational occurrence
05000390/LER-2017-00814 August 2017Shield Building Inoperability and Potential Loss of Safety Function Resulting from Spurious Equipment Operation
LER 17-008-00 for Watts Bar, Unit 1, Regarding Shield Building Inoperability and Potential Loss of Safety Function Resulting from Spurious Equipment Operation
Safe Shutdown
05000390/LER-2017-0078 August 2017Multiple Unreported Potential Loss of Safety Function Events Associated with Inoperable Single Train Systems Due to Misinterpretation of Reporting Guidance
LER 17-007-00 for Watts Bar, Unit 1, Regarding Multiple Unreported Potential Loss of Safety Function Events Associated with Inoperable Single Train Systems Due to Misinterpretation of Reporting Guidance
Safe Shutdown
Rod Drop Event
05000390/LER-2017-00631 July 2017Structural Degradation of 161 kV Line Pole Leads to a Condition Prohibited by Technical Specifications
LER 17-006-00 for Watts Bar, Unit 1, Regarding Structural Degradation of 161 kV Line Pole Leads to a Condition Prohibited by Technical Specifications
Safe Shutdown
05000390/LER-2017-00510 July 2017Isolation of the 1 B-B Safety Injection Pump Leads to Condition Prohibited by Technical Specifications
LER 17-005-00 for Watts Bar re Isolation of the 1B-B Safety Injection Pump Leads to a Condition Prohibited by Technical Specifications
Safe Shutdown
05000391/LER-2017-00322 May 2017Automatic Start of Auxiliary Feedwater System Due to Main Condenser Failure
LER 17-003-00 for Watts Bar, Unit 2, Regarding Automatic Start of Auxiliary Feedwater System Due to Main Condenser Failure
Safe Shutdown
Anticipated operational occurrence
05000391/LER-2017-00212 May 2017Manual Reactor Trip as a Result of a Secondary Plant Transient
LER 17-002-00 for Watts Bar, Unit 2, Regarding Manual Reactor Trip as a Result of a Secondary Plant Transient
Safe Shutdown
Anticipated operational occurrence
Power change
05000391/LER-2017-0013 May 2017Containment Airlock Function Lost Due to Equalizing Valve Not Closing
LER 17-001-00 for Watts Bar, Unit 2, Regarding Containment Airlock Function Lost Due to Equalizing Valve Not Closing
Safe Shutdown
05000390/LER-2017-0033 March 2017Inadequate Operability Determination Leads to a Condition Prohibited by the Technical Specifications
LER 17-003-00 for Watts Bar, Unit 1, Regarding Inadequate Operability Determination Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
Safe Shutdown Earthquake
Functionality Assessment
Pressure boundary leak
Through-Wall Leak
05000390/LER-2017-00222 February 2017Incorrectly Hung Clearance Leads to a Condition Prohibited by the Technical Specifications
LER 17-002-00 for Watts Bar Nuclear Plant, Unit 1, Regarding: Incorrectly Hung Clearance Leads to a Condition Prohibited by the Technical Specifications
Safe Shutdown
05000390/LER-2016-0119 December 2016Loss of Centrifugal Charging Pump Due to Repeat Failure of Associated Room Cooler
LER 16-011-01 for Watts Bar Nuclear Plant, Unit 1 Regarding Loss of Centrifugal Charging Pump Due to Repeat Failure of Associated Room Cooler
Safe Shutdown
Mission time
Past operability
05000391/LER-2016-00828 October 2016Reactor Trip Resulting from Failure of 2B Main Bank Transformer
LER 16-008-00 for Watts Bar, Unit 2, Regarding Reactor Trip Resulting from Failure of 2B Main Bank Transformer
Safe Shutdown
05000391/LER-2016-00519 August 2016Main Feedwater Pump Trip on Loss of Condenser Vacuum Leads to Turbine Trip and Reactor Trip
LER 16-005-00 for Watts Bar, Unit 2, Regarding Main Feedwater Pump Trip on Loss of Condenser Vacuum Leads to Turbine Trip and Reactor Trip
Safe Shutdown
05000390/LER-2016-0108 August 2016Emergency Diesel Generator Crankcase Pressure Switches Not Analyzed to Withstand the Effects of a Tornado
LER-16-010-00 for Watts Bar Nuclear Plant, Units 1 and 2 Regarding Emergency Diesel Generator Crankcase Pressure Switches Not Analyzed to Withstand the Effects of a Tornado
Safe Shutdown
Unanalyzed Condition
05000391/LER-2016-0044 August 2016Reactor Trip and Safety Injection Actuation Caused by Turbine Governor Valve Failure
LER 16-004-00 for Watts Bar, Unit 2, Regarding Reactor Trip and Safety Injection Actuation Caused by Turbine Governor Valve Failure
Safe Shutdown
Flow Induced Vibration
05000391/LER-2016-00327 July 2016Turbine Driven Auxiliary Feedwater Pump Inoperable for Longer than Allowable Outage Time due to Governor Valve Spring Over-Tensioning
LER 16-003-00 for Watts Bar, Unit 2, Regarding Turbine Driven Auxiliary Feedwater Pump lnoperable for Longer Than Allowable Outage Time Due to Governor Valve Spring Over-Tensioning
Safe Shutdown
Past operability
05000390/LER-2016-00815 July 2016Emergency Diesel Generator Manual Start Due to Loss of Voltage on the 6.9kV Shutdown Board 1B-B
LER 16-008-00 for Watts Bar, Unit 1, Regarding Emergency Diesel Generator Manual Start Due to Loss of Voltage on the 6.9kV Shutdown Board 1B-B
Safe Shutdown
Open Phase Condition
05000390/LER-2016-00915 July 2016Failure to Complete Surveillance Requirements Causes a Condition Prohibited by the Technical Specifications
LER 16-009-00 for Watts Bar, Unit 1, Regarding Failure to Complete Surveillance Requirements Causes Conditions Prohibited by the Technical Specifications
Missed surveillance
05000391/LER-2016-00211 July 2016Turbine Driven Auxiliary Feedwater Pump Inoperable for Longer than Allowable Outage Time due to Turbine Speed Control Failure
LER 16-002-00 for Watts Bar, Unit 2, Regarding Turbine Driven Auxiliary Feedwater Pump Inoperable for Longer Than Allowable Outage Time Due to Turbine Speed Control Failure
Safe Shutdown
Past operability
05000390/LER-2016-00630 June 2016Undersized Room Cooler Fan Shaft Results in Loss of Centrifugal Charging Pump
LER 16-006-00 for Watts Bar, Unit 1, Regarding Undersized Room Cooler Fan Shaft Results in Loss of Centrifugal Charging Pump
Safe Shutdown
Mission time
Past operability
05000390/LER-2016-00720 June 2016Technical Specification Action Not Met for Rod Position Indication
LER 16-007-00 for Watts Bar Nuclear Plant, Unit 1 Regarding Technical Specification Action Not Met for Rod Position Indication
Safe Shutdown
Rod Drop Event
05000391/LER-2016-00113 June 2016Loss of Automatic Containment Isolation for the Steam Generator Blowdown Sampling Lines
LER 16-001-00 for Watts Bar, Unit 2, Regarding Loss of Automatic Containment Isolation for the Steam Generator Blowdown Sampling Lines
Safe Shutdown
05000390/LER-2016-00423 May 2016Automatic Reactor Trip Due to Actuation of Over Temperature Delta Temperature Bistables
LER 16-004-00 for Watts Bar, Unit 1, Regarding Automatic Reactor Trip Due to Actuation of Over Temperature Delta Temperature Bistables
Safe Shutdown
05000390/LER-2016-00513 May 2016Both Trains of Unit 1 Emergency Gas Treatment System Inoperable During Unit 2 Testing
LER 16-005-00 for Watts Bar, Unit 1, Regarding Both Trains of Unit 1, Emergency Gas Treatment System Inoperable During Unit 2, Testing
Safe Shutdown
Stroke time
Safe Shutdown Earthquake
Past operability
05000390/LER-2016-00310 May 2016Technical Specification Surveillance Requirement Not Met During Emergency Core Cooling System Venting
LER 16-003-00 for Watts Bar, Unit 1, Regarding Technical Specification Surveillance Requirement Not Met During Emergency Core Cooling System Venting
Safe Shutdown
Probabilistic Risk Assessment
Temporary Modification
Missed surveillance
05000390/LER-2016-0024 May 2016Technical Specification Action Not Met for Inoperable Containment Isolation Valve
LER 16-002-00 for Watts Bar, Unit 1, Regarding Technical Specification Action Not Met for Inoperable Containment Isolation Valve
Safe Shutdown
05000390/LER-2016-0019 March 2016Channel Mode Switch in Incorrect Position Renders Lower Containment Atmosphere Particulate Radiation Monitor Inoperable
LER 16-001-00 for Watts Bar, Unit 1, Regarding Channel Mode Switch in Incorrect Position Renders Lower Containment Atmosphere Particulate Radiation Monitor Inoperable
Safe Shutdown
Grab sample
ML11347034313 December 2011Withdrawal of License Event Report 390/2011-003, Mode Change Without Meeting Limiting Condition for Operation (LCO) 3.7.5