- ML20054E096 (redirect page) (← links)
- 05000336/LER-1982-007 (redirect page) (← links)
- 05000336/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000336/LER-1982-053, Forwards LER 82-053/03L-0 (← links)
- 05000336/LER-1982-014-03, /03L-0:on 820506,outer Personnel Airlock Door Failed Zero Leakage Test.Caused by Door Pinching Gasket Seal When Attempts Made to Seal Door Tightly.Gasket Replaced & Personnel Instructed Not to Apply Excessive Force (← links)
- 05000336/LER-1982-007-03, /03L-0:on 820318,during Inservice Test of Steam Driven Auxiliary Feedwater Pump,Internal Pump Damage Discovered.Caused by Improper Clearance Tolerances on Balancing Drum.Pump Rebuilt & Maint Procedure Revised (redirect page) (← links)
- ML20054E101 (redirect page) (← links)
- 05000336/LER-1982-007-03 (redirect page) (← links)
- 05000336/LER-1982-007-03, Steam Driven Auxiliary Water Pump Exhibited Rubbing Noise within Pump During Inservice Test.Internal Pump Damage Found.Caused by Improper Clearance Tolerances on Balancing Drum (redirect page) (← links)
- ML20053A178 (redirect page) (← links)
- 05000336/LER-1982-005-03, /03L-0:on 820304,during Filling of Rcs,Power Operated Pressure Relief Valve 2-RC-403 Was Closed in Order to Isolate Leak in Body to Bonnet Joint.Leak Caused by Lack of Pressure & Temp in Rcs.Temp & Pressure Increased (← links)
- 05000336/LER-1982-006-03, /03L-0:on 820310,during Type B & C Local Leak Rate Testing During Refueling,Excessive Combined Leakage Rate Discovered.Caused by Mechanical Deficiencies in Valves & Personnel Access Hatch.Deficiencies Corrected (← links)
- 05000336/LER-1982-007, Forwards Updated LER 82-007/03X-1 (redirect page) (← links)
- 05000336/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000336/LER-1982-024, Forwards LER 82-024/03L-0 (← links)
- 05000336/LER-1982-021, Forwards LER 82-021/03L-0 (← links)
- 05000336/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000336/LER-1982-019, Forwards LER 82-019/99X-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000336/LER-1982-016, Forwards LER 82-016/01T-0 (← links)
- 05000336/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000336/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000336/LER-1982-005, Forwards LER 82-005/03L-0 (← links)
- 05000336/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000336/LER-1982-040, Forwards LER 82-040/03L-0 (← links)
- 05000336/LER-1982-038, Forwards LER 82-038/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-039, Forwards LER 82-039/03L-0 (← links)
- 05000336/LER-1982-036, Forwards LER 82-036/03L-0 (← links)
- 05000336/LER-1982-046, Forwards LER 82-046/03L-0 (← links)
- 05000336/LER-1982-047, Forwards LER 82-047/03L-0 (← links)
- 05000336/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000336/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000336/LER-1982-034, Forwards LER 82-034/03L-0 (← links)
- 05000336/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000336/LER-1982-033, Forwards LER 82-033/03L-0 (← links)
- 05000336/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000336/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000336/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000336/LER-1982-028, Forwards LER 82-028/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-052, Forwards LER 82-052/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-026, Forwards LER 82-026/03L-0 (← links)
- 05000336/LER-1982-044, Forwards Updated LER 82-044/03X-1 (← links)
- 05000245/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000336/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000245/LER-1982-012, Forwards LER 82-012/01T-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-013, Forwards LER 82-013/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000245/LER-1982-011, Forwards LER 82-011/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-009-01, Review of ECCS Subsystem Revealed Mode Changes Occurred Operating Under Action Statement.Caused by Misinterpretation Between Tech Spec Sections.Tech Spec Changed to Reduce Confusion (← links)
- 05000336/LER-1982-049-01, Fire Water Storage Tanks a & B Found at 190,153 Gallons & 190,074 Gallons, Respectively.Caused by Stripped Gear in Makeup Valve Operator a & Sticking Brake in Operator B (← links)
- 05000336/LER-1982-008-03, Reactor Coolant Pump Speed Sensing Bistable Trip Setpoint Found Out of Spec. Caused by Instrument Drift.Bistable Trip Unit Replaced.W/ (← links)
- 05000336/LER-1982-053-03, /03L-0:on 821228,while Placing C Reactor Bldg Closed Cooling Water (RBCCW) Back in Svc,Operator Failed to Align B RBCCW W/Svc Water Header.Caused by Personnel Error. Use of Procedures re-emphasized W/Dept Personnel (← links)
- 05000336/LER-1982-052-03, /03L-0:on 821231,leak Found on Discharge of C Svc Water Pump.B Svc Water & high-pressure Safety Injection (HPSI) Pumps Were Lined Up to Facility II Emergency Bus Leaving One HPSI Operable.Caused by Shutdown of C Svc Pump (← links)
- 05000336/LER-1982-043-03, During Power Ascension, Broken Hydraulic Snubber Stud Discovered & Traced to Hanger 490001 on Main Steam Lead to High Pressure Turbine.Caused by Constant High Vibration (← links)
- 05000336/LER-1982-026-03, /03L-0:on 820623,three Containment Air Radiation Monitors (8123A,8262A & 8262B) Found W/Function Swithces in Incorrect Position.Caused by Techician Error & Procedural Deficiency.Technicians Cautioned & Procedure Revised (← links)
- 05000336/LER-1982-044-03, While Performing in-core Detector Alarm Update,Alarm Values Updated Incorrectly, Resulting in Nonconservative Alarm Values for in-core Detectors.Caused by Plant Calorimetric out-of-svc (← links)
- 05000336/LER-1982-041-03, /03L-0:on 821019,control Element Assembly 23 Dropped Fully Into Core.Caused by Failure of Coil Power Programmer 5-volt Dc Power Supply.Upper Gripper Power Switch Replaced (← links)
- 05000336/LER-1982-040-03, /03L-0:on 820918,acceptance Criteria Not Met When Containment Personnel Airlock Test Performed.Caused by Leaking Gasket on Inner Airlock Door.Gasket Replaced & Successful Leak Test Performed (← links)
- 05000336/LER-1982-038-03, /03L-0:on 820918,surveillance Testing Indicated Activity of 0.99 Uci Dose Equivalent I-131 in Primary Coolant.Caused by Small Number of Degraded Fuel Pins (← links)
- 05000336/LER-1982-039-03, /03L-0:on 820914,packing for Operator Shaft in Primary Containment Outer Air Lock Door Leaked & Test Pressure Could Not Be Maintained.Caused by Normal Cyclic Wear.Packing Tightened (← links)
- 05000336/LER-1982-046-03, /03L-0:on 821130,A & B Charging Pumps Removed from Svc & Manually Isolated.Caused by Attempt to Quantify Charging Pump Packing Leakage Per ALARA Considerations.No Corrective Action Required (← links)
- 05000336/LER-1982-047-03, /03L-0:on 821201,while at 100% steady-state Operation,Both Boric Acid Pumps de-energized to Install Noise Suppression Devices on Vol Control Tank Makeup & Reject Relays.Pumps re-energized After Installation (← links)
- 05000336/LER-1982-035-03, /03L-0:on 820812,during Transient,Pressurizer Pressure Decreased Below Min Tech Spec Limits.Caused by Closed Suction Valve for Coolant Makeup,Allowing Only Highly Borated Water in Sys.Caution Sign Posted (← links)
- 05000336/LER-1982-034-03, /03L-0:on 820801,while Performing Plant Heatup, Change from Mode 5 to Mode 4 Was Made W/O Performing Required Surveillance of Containment Personnel Airlock. Caused by Operator Error (← links)
- 05000336/LER-1982-020-03, /03L-0:on 820528,inservice Insp Test EN 21136 Not Completed within Required Time.Caused by Rescheduling Due to Operational Problems.Operations Supervisor Will Ensure That Future Testing Completed as Required (← links)
- 05000336/LER-1982-033-03, /03L-0:on 820722,while Testing Steam Driven Auxiliary Feedwater Pump,Turbine Failed to Reach Min Rpm. Caused by Insufficient Steam Supply.Steam Valve Collar Adjusted (← links)
- 05000336/LER-1982-030-03, /03L-0:on 820715,control Element Assembly Motion Inhibit Interlock Did Not Function Properly.Caused by Faulty Operational Amplifier in Group 8 of out-of-sequence Scanner. Amplifier Replaced (← links)
- 05000336/LER-1982-031-03, /03L-0:on 820712,during Routine Surveillance Testing,Train a of Ebfs Could Not Be Verified as Operable. Caused by Failure of Honeywell Power Supply Circuit Board H01 in Humidity Controller W7500.Board Replaced (← links)
- 05000336/LER-1982-029-03, /03L-0:on 820702,while at 100% Power,Weld Leak Discovered on 3/4-inch Inlet Line to Charging Pump B Discharge Relief Valve.Cause of Weld Failure Unknown.New Section of Pipe Installed (← links)
- 05000336/LER-1982-028-03, /03L-0:on 820712,surveillance Testing Indicated I-131 Concentration Higher than Allowed by Tech Spec.Caused by Defective Fuel Pins.Power Increases Will Be Limited to Prevent Addl Fuel Defects (← links)
- 05000245/LER-1982-014-03, /03L-0:on 820614,emergency Svc Water Pump D Failed to Meet Min Pump Discharge Pressure During Operational Readiness Test.Caused by Accumulation of Marine Growth & Mussels on Pump & Suction Volutes.Pump Cleaned (← links)
- 05000336/LER-1982-027-03, /03L-0:on 820619,control Element Assembly Motion Inhibit for All Control Element Assembly Groups Discovered Inoperable.Caused by Failed Nand Logic Chip (S/N 742ON) Due to Loss of Motion.Chip Replaced (← links)
- 05000336/LER-1982-025-03, /03L-0:on 820618,control Element Assembly 44 Inserted Into Step 174 & Could Not Be Withdrawn.Caused by Inoperable Pull Down Power Circuit Due to Loose Connection Between Timer Module & Power Switch.Connection Tightened (← links)
- 05000245/LER-1982-012-01, /01T-0:on 820702,timer Which Inhibits Throttling LPCI Valve During First 5 Minutes Following LPCI Sys Initiation Found Wired Incorrectly.Timer Rewired & Tested Satisfactorily (← links)
- 05000245/LER-1982-013-03, /03L-0:on 820615,while Performing Gas Turbine Emergency Fast Start Test,Gas Turbine Failed to Start.Caused by Lack of Air to Air Start Motor Due to Rusty Air Pressure Regulating Valve.Valve Replaced (← links)
- 05000336/LER-1982-022-03, /03L-0:on 820609,fire Actuation Signal in Diesel Generator Room a Tripped Clean Fuel Transfer Pump,Allowing Clean Fuel Tank to Overflow.Caused by Shorted Fire Alarm Pull Box,Due to Ingress of Rainwater.Shield Installed (← links)
- 05000336/LER-1982-024-03, /03L-0:on 820606,120-volt Ac (VIAC-1) Lost Causing Power Fuses to Blow in Facility I ESAS Cabinet.Caused by Roof Leak Resulting from Heavy Rains Allowing Water to Enter Top of Inverter & Shorting Circuitry.Water Shield Insta (← links)
- 05000336/LER-1982-021-03, /03L-0:on 820604,during Routine Operations,Steam Jet Air Ejector Fire Damper 2-EB-109 Failed Shut.Caused by Failure of Metal Band Required to Hold Damper Open Due to Corrosion.Damper Band,Link & Damper Blades Replaced (← links)
- 05000336/LER-1982-018-03, /03L-0:on 820527,containment Atmosphere Particulate Radioactivity Monitoring Channels Became Inoperable When Indication Went Offscale High.Caused by Valve Leakage.Detector Shielding Added (← links)
- 05000336/LER-1982-017-03, /03L-0:on 820526,at 100% power,1800 Computer Processing Unit Declared Inoperable Because of Inability to Write Into Display Storage Address Register.Caused by Failure of Circuit Card.Card Replaced (← links)
- 05000336/LER-1982-016-01, /01T-0:on 820607,12-inch Ductile Cast Iron Cement Lined Underground Fire Main Broke on Const Site,Causing Both Fire Protection Storage Tanks to Fall Below Min Requirement. Cause Not Determined.Break Isolated & Tanks Refilled (← links)
- 05000245/LER-1982-011-03, /03L-0:on 820508,gas Turbine Trouble Annunciator Alarmed on Panel 908 in Control Room.Caused by Shorted Undervoltage Relay for Ac Lube Oil Pump.Undervoltage Relay Replaced.One Amp Fuse Will Be Added (← links)
- 05000336/LER-1982-015-03, /03L-0:on 820513,reactor Protection Sys Channel a Low Steam Generator Pressure Bypass Removal Bistable Card Setpoint Found to Be Out of Spec.Caused by Instrument Setpoint Drift.Bistable Card Setpoint Will Be Replaced (← links)
- 05000245/LER-1982-008-03, /03L-0:on 820318,breakers for Main Steamline Drain Valve,Inboard Torus Spray Stop Valve & Inboard Drywell Spray Stop Valve Found Tripped.Caused by Water Soaking Through Environ Encl Penetration Seal (← links)
- 05000245/LER-1982-008, Forwards LER 82-008/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-010-03, /03L-0:on 820413,while Performing Emergency Svc Water Sys Operational Readiness Test,Valve 1-LPC-4A Failed to Open When Emergency Svc Water Pumps Started.Caused by Excessive Play in Potentiometer.Slider Adjusted (← links)
- 05000245/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-013-03, /03L-0:on 820417,while at 100% Steady State Operation,Grounded Bus Traced to 2-CH-514 (Boric Acid Emergency Supply Charging Pump Suction).Plant Trip Occurred. Caused by Ground on Motor Valve Operator Overheating (← links)
- 05000336/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- ML20053A162 (redirect page) (← links)
- 05000336/LER-1982-012-03, /03L-0:on 820417,RBCCW Heat Exchanger Outlet Temp Control Valve 2-SW-8.1A Operated Erratically During Inservice Testing.Caused by Sheared Link/Shaft Pin.Shear Pin Replaced & Valve Tested Satisfactorily (← links)
- 05000336/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000245/LER-1982-009-03, /03L-0:on 820412,while Performing High Pressure Scram & Containment Isolation Functional Calibr Test, Pressure Switch 2206-1612D Failed to Trip at Desired Setpoint.Caused by Setpoint Drift.Switch Replaced (← links)
- 05000245/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-011-03, /03L-0:on 820405,RCS Temp Dropped to 514 F.Caused by Borating to Control Xenon While Placing Turbine on-line Which Caused Power Reduction & Cooldown.Control Element Assemblies Withdrawn to Increase Power & Temp (← links)
- 05000336/LER-1982-011, Forwards LER 82-011/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000336/LER-1982-010-03, /03L-0:on 820401,while at 100% Power,Svc Water Header a Removed from Svc to Repair Leak in Pipe Downstream to Reactor Bldg Closed Cooling Water HX Isolation Valve. Caused by Coating Failure.Leak Repaired (← links)
- 05000336/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000336/LER-1982-009, Forwards LER 82-009/01T-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-007-03, /03L-0:on 820315,while Performing Isolation Condenser Isolation Instrument Functional & Calibr Test, Switch 1350B Tripped at 147 Inches of Water.Caused by Setpoint Drift.Switch Recalibr (← links)
- 05000245/LER-1982-007, Forwards LER 82-007/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-004-03, /03L-0:on 820126,pressure Channel for 1 of 2 Motor Operated Shutdown Cooling Isolation Valves Found to Be Approx 80 Psi Above Tech Specs.Caused by Shift in Zero Point of transmitter,Fisher-Porter Model 50EP 1042BC5A (← links)
- 05000336/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000245/LER-1982-006-03, Le 82-006/03L-0:on 820212,MSIV 1-MS-2C Closing Time Exceeded Tech Spec Range.Caused by Maladjustment of Control Valve Hydraulic Cylinder.Cylinder Speed Readjusted (← links)
- 05000245/LER-1982-006, Forwards LER 82-006/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-005-01, /01T-0:on 820224,HFA Relay 595-113D Coil Bobbin Found Severely Melted & Four Other Relays Found W/Initial Signs of Melting.Apparently Caused by Use in Continually Energized Application,Raising Temp to Melting Point (← links)
- 05000245/LER-1982-005, Forwards LER 82-005/01T-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-004-03, /03L-0:on 820212,during Containment Isolation Valve Operability Demonstration,Isolation Condenser Condensate Return Valve 1-IC-3 Failed to Open Upon Signal. Caused by Contraction Upon Cooling.Valve Heated to Open (← links)
- 05000245/LER-1982-004, Forwards LER 82-004/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-003-01, /01T-0:on 820217,while Switching to Isolate North 345 Kv Line Circuit Switcher 15G-2T-6 Faulted Phase a to B Causing Fire to Circuit Switcher.Caused by Interrupter Contact within Circuit Switcher Failed in Open Position (← links)
- 05000245/LER-1982-003, Forwards LER 82-003/01T-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-001-03, /03L-0:on 820115,while Performing Steam Line High Flow Functional Test,Switches 261-2B & 261-2D Failed to Trip at Desired Setpoint.Caused by Setpoint Drift.Switches Recalibr (← links)
- 05000245/LER-1982-001, Forwards LER 82-001/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-002-03, /03L-0:on 820115,B Emergency Svc Water Pump Declared Inoperable After Failure to Meet Min Pump Discharge Pressure.Caused by Marine Fouling of Pump Suction W/Possible Slippage of Second Stage Impeller to Pump Shaft (← links)
- 05000245/LER-1982-002, Forwards LER 82-002/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-003-03, /03L-0:on 820104,fan F394 Tripped on Overload, Rendering Radiation Monitors 8123A & B Inoperable.Caused by Seized Bearings Due to Lack of Lubricaton.Blower Replaced. Proper Drainplug Installation Will Be Verified (← links)
- 05000336/LER-1982-003, Forwards LER 82-003/03L-0 (← links)
- 05000336/LER-1982-002-03, /03L-0:on 820106,w/plant in Shutdown for Refueling,Fuses in Inverters 2 & 6 Blew Resulting in Loss of Vital Instrument Panel VA-20 & Causing Closure of Overpressure Circuit.Caused by Short Circuited Test Lead (← links)
- 05000336/LER-1982-001-04, /04T-0:on 820121,recording Device for Radiation Monitor Found Out of Svc During Liquid Radwaste Discharge to Long Island Sound.Caused by Removal of Recorder for Calibr. Recorder Labeled (← links)
- 05000336/LER-1982-001, Forwards LER 82-001/04T-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-050-03, /03L-0:on 821231,primary Coolant Activity Found Above Limit of Uci Per G Dose Equivalent I-131.Caused by Small Number of Degraded Fuel Pins.Iodine Concentration Decreased (← links)
- 05000336/LER-1982-050, Forwards LER 82-050/03L-0 (← links)
- 05000336/LER-1982-051-03, /03L-0:on 821223,while at 100% Power,Plant Computer Malfunctioned & Declared Inoperable.Caused by Defective Analog Sys Driver Card,Ibm Part 5800013.Card Replaced & Computer Operation Restored (← links)
- 05000336/LER-1982-051, Forwards LER 82-051/03L-0 (← links)
- 05000245/LER-1982-031-03, /03L-0:on 821214,while Performing Main Steam Line High Flow Functional Calibr Test,Pressure Switch 261-21 Tripped at 95.75 Psid,Above Tech Spec.Caused by Setpoint Drift.Pressure Switch Reset (← links)
- 05000245/LER-1982-031, Forwards LER 82-031/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-030-03, /03L-0:on 821213,during Functional Test,Isolation Condenser 1-1C-4 Failed to Close on Isolation Signal or Remotely from Control Room Panel 903.Caused by Torque Switch Operating Prematurely Due to Sticking Condition (← links)
- 05000245/LER-1982-030, Forwards LER 82-030/03L-0.Detailed Event Analysis Encl (← links)
- 05000245/LER-1982-020-01, During Hydraulic Snubber Functional Test,Four Itt Grinnell Snubbers Failed to Meet Design Acceptance Ranges.Caused by Oil Leakage Through Cracked Reservoir Glass.Snubbers Repaired (← links)
- 05000245/LER-1982-020, Forwards Updated LER 82-020/01X-2.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-049, Forwards LER 82-049/01T-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-048-03, /03L-0:on 821210,power Lost to 120-volt Ac Vital Bus VIAC-3.Caused by Worker Accidentally Bumping Static Switch,Resulting in Supply Being Switched from Alternate to Normal.Switch Covers Installed (← links)
- 05000336/LER-1982-048, Forwards LER 82-048/03L-0 (← links)
- 05000245/LER-1982-029-03, /03L-0:on 821207,fire Water Storage Tank a & B Levels Found Below Tech Specs.Caused by Stripped Gear in Tank a & Sticking Gear in Tank B.Tanks Refilled.Gear & Valve Lubricated (← links)
- 05000245/LER-1982-029, Forwards LER 82-029/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000336/LER-1982-045-03, /03L-0:on 821027,at 100% Power,Control Room Air Conditioning Sys 1 Was Lost.Caused by Broken Wire Which Shifted Shorting Power Supply Due to Personnel Error.Wire Repaired & Air Conditioning Sys Returned to Svc (← links)
- 05000336/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000245/LER-1982-025-03, /03L-0:on 821026,pressure Switch 263-55C Tripped Above Tech Spec During Reactor Vessel High Pressure Functional & Calibr Test.Caused by Setpoint Drift.Switch Reset & Satisfactorily Tested (← links)
- 05000245/LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl (← links)
- 05000336/LER-1982-042-03, /03L-0:on 821009,plant Computer Automatically Shut Down Due to Accidental Initiation of Halon Fire Suppression Sys.Caused by Const Matl Being Bumped Hitting Fire Station Box Pull Handle.Matl Properly Stored (← links)
- 05000336/LER-1982-042, Forwards LER 82-042/03L-0 (← links)
- 05000336/LER-1982-002, Forwards LER 82-002/03L.Detailed Event Analysis Encl (← links)