San Onofre, Unit 2, Enclosure 6, LTR-SGDA-12-36, Rev. 3, Flow-Induced Vibration and Tube Wear Analysis of the San Onofre Nuclear Generating Station Unit 2 Replacement Steam Generators Supporting Restart. Cover Through Page 227 of 415
ML13051A197
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 02/15/2013
From: Bell B A, Cullen W K, Hall J M, Langford P J, Norman T L, Pournaras T J, Prabhu P J, Thakkar J G
Westinghouse
To:
Office of Nuclear Reactor Regulation
References
TAC ME9727 1814-AA086-M0238, Rev 0, LTR-SGDA-12-36, Rev 3