MONTHYEARML24354A1312024-12-19019 December 2024 LLC, Response to NRC Request for Additional Information No. 032 (RAI-10297 R1) on the NuScale Standard Design Approval Application ML24354A2522024-12-19019 December 2024 Nuscale Power, LLC - Response to Request for Additional Information No. 032 (RAI-10297 Ri) on the Nuscale Standard Design Approval Application ML24353A2182024-12-18018 December 2024 LLC, Response to NRC Request for Additional Information No. 037 (RAI-10357 R1) on the NuScale Standard Design Approval Application ML24353A0292024-12-18018 December 2024 Nuscale Power LLC - Responses to NRC Request for Additional Information No. 011 (RAI-10111 Ri) on the Nuscale Standard Design Approval Application ML24353A2522024-12-18018 December 2024 LLC, Response to NRC Request for Additional Information No. 031 (RAI-10296 R1) on the NuScale Standard Design Approval Application ML24353A3332024-12-18018 December 2024 Nuscale Power, LLC - Response to NRC Request for Additional Information No. 037 (RAI-10357 Ri) on the Newscale Standard Design Approval Application ML24348A0632024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-44 ML24348A0072024-12-13013 December 2024 LLC Submittal of the NRCs Request for Docketing of Resolved Audit Responses ML24348A0522024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-36 ML24348A0272024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-23 ML24348A0872024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-68 ML24348A0432024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-30 ML24348A0812024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-59S2 ML24348A0332024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-26 ML24348A0672024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-44S ML24348A0732024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-57 ML24348A0292024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-24 ML24348A0202024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-8 ML24348A0702024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-49 ML24348A0692024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-45 ML24348A0582024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-39 ML24348A0452024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-33 ML24348A0122024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-5 ML24348A0612024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-41 ML24348A0142024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-5S ML24348A0542024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-37 ML24348A0752024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-58 ML24348A1132024-12-13013 December 2024 Nuscale Power, LLC - Response to NRC Request for Additional Information No. 037 (RAI-10357 R1) on the NuScale Standard Design Approval Application ML24348A0772024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-59 ML24348A0622024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-43 ML24348A0242024-12-13013 December 2024 Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-22 ML24327A1492024-11-22022 November 2024 LLC, Responses to NRC Request for Additional Information No. 024 (RAI-10185 R1) on the NuScale Standard Design Approval Application ML24326A1232024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.5.1-4 ML24326A1112024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.3.1-9 ML24326A1252024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.5.1-5 ML24326A1122024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.3.1-11 ML24326A3362024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-38 ML24326A0942024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-9 ML24326A0962024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-14 ML24326A0982024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.0.4-1 ML24326A3452024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-42 ML24326A0952024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16-13 ML24326A3342024-11-21021 November 2024 Response to NuScale Topical Report Audit Question: A-LOCA.LTR-37 ML24326A1352024-11-21021 November 2024 Response to NuScale Technical Report Audit Question Number: A-16.3.6.3-2 ML24313A0662024-11-0808 November 2024 LLC - Response to NRC Request for Additional Information No. 015 (RAI-10133 R1) on the NuScale Standard Design Approval Application ML24313A1212024-11-0808 November 2024 LLC - Response to NRC Request for Additional Information No. 020 (RAI-10150 R1) on the NuScale Standard Design Approval Application ML24313A0522024-11-0808 November 2024 LLC Response to NRC Request for Additional Information No. 14 (RAI-10131 R1) on the NuScale Standard Design Approval Application ML24281A0182024-10-0707 October 2024 LLC, Response to NRC Request for Additional Information No. 017 (RAI-10135 R1) on the NuScale Standard Design Approval Application ML24281A0202024-10-0707 October 2024 LLC, Response to NRC Request for Additional Information No. 023 (RAI-10177 R1) on the NuScale Standard Design Approval Application ML24271A2822024-09-27027 September 2024 LLC - Response to NRC Request for Additional Information No.026 (RAI-10199 R1) on the NuScale Standard Design Approval Application 2024-09-27
[Table view] |
Text
NuScale Nonproprietary Response to SDAA Audit Question Question Number: A-11.5-3 Receipt Date: 06/05/2023 Question:
Inital Question:
How is NuScale addressing the calibration requirements for their radiation monitoring? Previously the applicant referenced information on EPRI TR-102644 and RG 1.21 but this information is no longer included in the SDAA Section 11.5.
NRC Follow-up Response:
The response to item A-11.5-3 is not adequate. NuScale proposes updates to the application to provide a little detail on radiation monitor calibration, but the level of information provided is not sufficient. The response says radiation monitor calibration will follow ALARA principles and industry guidance but does not provide any indication of what the industry guidance being used is. The application should contain a similar level of detail regarding the calibration of radiation monitors as was provided in the DCA. As an alternative, the SDA should provide a COLA item for the COL applicant to provide additional information regarding the calibration requirements for radiation monitors.
Response
NuScale SDA Section 13.5 includes COL Item 13.5-6 that requires applicants to describe site-specific maintenance and other operating procedures, which include calibration and test procedures. NuScale partially conforms to Regulatory Guide (RG) 1.21. Issuance of the calibration and test procedures is the responsibility of the COL applicant.
No changes to the SDAA are necessary.