Independent Spent Fuel Storage Installation - Revision 28 to Updated Safety Analysis Report, Chapter 13, Figures
ML20335A077
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 11/18/2020
From:
Exelon Generation Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20335A110 List:
References
Download: ML20335A077 (1)


Text

Zone 3 Zone4 Zone4 Zone 3 I

{

Zone3 Zone 3 Zone2 Zone2 201 e3 q>ne ~

II Zonc4 Zonc2 Zone l Zone 1 Zonc2 Zooe4 Zonc4 Zonc2 Zone I Zone 1 Zone2 Zone4 n u ll Zone3 Zone 3 Zone2 Zone2 Zone 3 Zone 3

,_ --~

- ~

__j Zo ne*) Zone Zone4 Zone 3 Heat Zone Level NoofFA kW/FA Tota1 l I 4 0.8 3.2 2 g 1.0 8.0 3 I 12 1.0 12.0 I

4 g 0.8 6.4 Total Heat Load. kW 19.6 Note: Four zones are employed to denote an increasing imponance 1.0 dose rates, where Zone I. represenls the least important zon and Zone 4 11epresents the most important zone.

USAR Calvert Cliffs Independent HEAT LOAD ZONE CONFIGURATION FOR THE Figure 13.3-1 Spent Fuel Storage Installation MAXIMUM HEAT LOAD IN A NUHOMS-32PHB Revision 26