6 to Updated Final Safety Analysis Report, Figure 3.2-9, Sheet 4 of 12, Drawing 108009, Revision 77, Sheet 4, Safety Injection System
ML21305A721
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A721 (1)


Text

40 41 42 43 44 45 46 47 48 49 V r7 CHARG I 1,1G G-0283 11\ISIDE OUTSIDE PUJvlPS DISCH S2-3/4 r1~WATER FILL COIIT A I IIMEllT COl!T A I l!MEl~T

~---< 08 45B-B \ .* G-0283 TO CASK WASHDOWIJ AREA, FUEL HA~IDL I IIG

~ RE!vlOVABLE CAP BLDG FLOOR ORA I IJ IIOT E 2 IIOTE I8 FX 924 E NOTE II LI E

8902A 14 -T 58 8903A

~i4-T58  ;<s61434sl 31:i) r,JOTE I8 Pl 155

~AUX BLDG FROM COl~T A I l~lvlEII T SPRAY TEST L I 11 E DISCH FROH BORIC ACID BLEl~DER 965 30 II RO

3l4-T58 SUHP & PUHR 39-E I2 41B-E 08 VEIH NOTE 7 / 559 (S6 I -1/~! G-0283 N

,J) 811-,

A -/ "-IOTE. L___~ ~ - -

(s2I 61 512) 1s5 1991 11/,SPL - 5 H I ..,__~

i\1

- -....-11 ~

D G-0283 SI PUMPS ' 111 8970A PG

~OA 8810A 6 x4 REFUEL I 1,1 G WATER 1/, T58 R:CS LOOP I 1'1% C58 DR FE 58 _0 ~..-__J_-=-::-r::-:--::--:r:sc:--__j__h-_ _ _ _ _ _-----=r--LJ-("=s=2=l2=6=4=1l=4)::__--1, STORAGE TANK 2- I COLO LEG 0MB T5T 92.4 I 16-E 34- S2 2064 2 4 X2 @t(D(171A-AI 33) s6 ~/4 ,---r--r-*1 39-B 8969 S6 TO TEST I -T58 8972 LT 3/4-T58 L Jl,IE HOR S6 2075 I A 9 U)CAL 2-T58 920

[\JOTE 2 F ,. TAIW BY PG&E

" 293-E I S2 I 896 8 927 O

DC-66307 I - I 29

+

RO IJOTE S6 I 9 7 8 4 DC-663071 - I 34 555 20 39-A I9 25-B I 3

~

680/,A DISCH FROM REACTOR

sGI 199513) A 4 6M58FN ~110T E 9 IIOTE 13 COOL DOWIJ TA 111<

DISCH FROM REFUEL[l,IG WTR PURIFICATIOI~

8975 4 x42D D ,;-i TV&V PUMP DISCH NOTE 8

?/4" G-0283 ITEM 81 SPEC 8729 D

)4-T58 NOTE I9 6 I 1/:U co 8907 l~OTE I4 T58 0 S2 26 I I 2 PRIMARY M WATER STOR l93 S6 282 3 (S6 I :1/4)

TO PLA~IT YARD 39-C I 2 TAl'W 2-1 1-EI ORA I 11 [\JORHAL REFUEL WATER SUPPLY 1167 i'IOTE 2 FX S6 2033 4 TO CONTAINMENT SPRAY 926 w 8820 OPERATION PPS SUCTION HEATER

( s I l/4) 3-C58 TYP 2

=

co S6 283 3

(_/) SAMPLE SJl,tl<

I EL. I 00' AUX, BLDG, I S6 I 919 4 e C A B '5 146 A :I l"x0,065 S.S S2-l"-J* ' STR

~98~2 ~M TIJBil!Gr 463 **.'52-1" 4>< 3 r.,

3805A ,-;iV 1LOOR ORA I 1,1

~* _ 880 I B 8-GM42FB o/4X4'2D 4 1

~H58FII q) a C, C C 3/ I 1 Ill

/4 X /4 0 'I;)

IIOT E I 9 148 A~ ~

I / I/

/ 4 X / 16 NOTE 22

,-8902B

,( e,z4 8805B P' ~14-T58

. 89036

~ ~-----

(S6I2573 I I)

S 7 0 2 6 /16 B 8 C4'l. 8-GM42F6 S2 221 18

~;4 - T 5 8 8803A 4 -GH58FI~ ,(298-El32)

I TE!=' 56 1974 4 REFUEL WATER SUPPLY (ill) TO RESIDUAL HEAT REMOVAL PUMPS 8900B RCS LOOP 2 I '/rC58 331  ;; HISC EO COLD LEG T 4 r,DRTf'.O-I

!SE r i._56-2323-7'4 Sll9718IIIP) 3/4-TS r:,

S6 3/4 A 5 TEST COIHI &

ACCUM FILL LIIIE CDtill 1S6 7178

'I B E 2 AL TERl,IATE C1 I 3 IO 309 38- C r'lf--____L---~..----=i::==:;::::=:::::-----i.J VE 3/4" z _!_

N o B S2 4256 14 DR (s6 I3/4) S6 L!.J D w

IIOTE 23 DC-~OOa.'-1-7.3-97 -E: f-0 z 8860 3 I I Zl:18 D :3Z)  ;/4 - T 5 8

<32A-B I r 9) 8803B NOTE?> Sbil9754 CLOSED 4 -GM58FII DRA 111 3~ n 8859B NOTES:

I. DELETED L'J TC m ~~x1--S6-2329-3/4 IIOTE I 9 308B-E 32 L(J 8807B

2. FLOWW METER [ l,JG OR IF I CE TO VERIFY FLOW(IE@ 20. THE RESTRICTING ORIFICE ASSEMBLY CONSISTS OF A PRESSURE 4-GH42FB 0

DURING PRE OPERATIONAL TESTIIIG ~

N 12. FIELD TO l~ISTALL BOSS PER FIG-343, DWG 053093 ~ RED UC I IIG OR IF I CE (PRO), A SWAGE TYPE REDUCER All A FLOW I 303B-E 32 C'"l 3. DELETED 13. ~;~ ANCHOR/DARL[l,JG, MODEL 1878, BOLTED BOl,IIET, GATE VALVE, BAFFLE PER DRAWING DC 663230-409 (el-D1C)

PO" 722739 ITEH 3, DC-6006473-7 ~

0 4. F'G ll~DICATES F'G&E CO SCF'OE N

I

21. f4" AIJCHOR DARLil!G GLOBE VALVE, S/C 95-2755, 0 5. VALVES ARE SET TO BALANCE ECCS INJECTION FLOWS I 4 . BL All K FL ANGE I S PG & E P I PE CODE CLASS " C " , (IE[> DC 6011930-79.~

AND TO PREVENT RUHR RUNOUT, THEN CONTROLLED IN THE C

CJl J, THROTTLED P O S I T i m L ~ 15, DELETED 22. FOR LINE 7026- 1/15: 58-E u

~ V~

U)

+-

6. ALL WESTINGHOUSE ITEH NUHBERS SHOWN WITHOUT PREFIX PG&E SI IN SIS ARE
16. DELETED PG&E S-SPEC WITH THE FOLLOWING SPECIAL REQUIREMENTS:

-TUBll,JG SIZE SHALL BE 1/15" OD WITH WALL THICKI\JESS OF 0. 020" REF. DWG. DC 663216-63 SAFETY I llJ, PUHR 2- I SUCT I 01.1 LJI\J IT A m . ::::i -SEAMLESS STAINLESS STEEL TUBING MATERIAL GRADE TP304 HAY BE 0

0 7 Ct:

V.) :z 7.

8.

SPECIAL LIIIE WHE~I WATER IIJSULATIOI~ IIICLUOIIJG C H E C K ~

IS cmnAH[I.JATEO BLl~ID FLA~IIIGE Ci) 17. DELETED SUBSTITUTED FOR GRADE TP316, ALL OTHER REQUIREMENTS OF DI ABLO CAI\IYOI\J POWER PLAI\JT ro m ::-;: S-SPEC SHALL APPLY.

ooc_

- 0 *,

WITH HOSE BIBB HUST BE INSTALLED DRAINING

-LEl~GTH OF Lil!E 7026-/15: 24 FEET+./- 2 FEET (REF. DCP N-50631 i SAFETY [I\IJECTIOI\I S(STEM I CO ,1*, TO MISC EQUIP DRAIN TANK 0-1 18. I" Al!CHOR DARLl~IG GLOBE VALVE 1878, STOCK CODE 94-3771

i:: o :n 11--:i 9. VELAII Hl,JF VALVE (42,43-D)(42,43-C)(45-B,C)

DC-6006473-157 ~ 23. MECHANICAL TRAVEL STOP INSTALLED ON VALVE 310 TO LIMIT OPEN STEM TRAVEL DRAW I 1,1G SHEET PAGE REV

1. REF: DWG" 60 I 1930-140, PAGE 3 )~~___,,~,

08009 0

- I

10. CHAIN OPERATED<TI)G) I 9 , 14 " A11 CHOR DAR L I NG GLOBE VALVE , STOCK CODE 9 4 - 2 8 2 0 I I. EHBEDDED PI PE, 1\10 L ll1E IJUHBER (ED DC-6006473-97 ( "2-D!C) e5-1>B) < 24. co1n1ECTIO~I POI~IT FOR FLEX EQUIPIIEJ,n<J:2) ~

31-P:OIC 3 Size

. .:_I=-0=-5-1-------+-------+------ REV I S E D P E R DD N - 2

  • I 3 2 4 1-0_2_-0_3_-_2_0_1_5+-lv_JN_R_U+-F_x_C_2-+K_,_JD--=-3+-fl_::_O_T_R-=E-=Q-=U-=I_R-=E=-=D'---P-=E=-R-'----C=-F_3=-=-

L,i, It:. _:'v./f.l l \J ~'hi,~ l:.', "l r,'.J!\_ ::.IE, l ii::.::.-: