ML21305A721
Text
C E
D C
B L(J 0
N I
C'"l 0
I N
0 CJl J,
u
+-
~ ~
U) V m
. ::::i 0
7 Ct:
0 V.) :z ro m ::-;:
ooc_
-0 *,
I CO,1*,
- i:: o :n 11--:i I
40 RO IIOT E 2 FX 924 8902A 14 -T 58 41 11\\ISIDE COIIT A I IIMEllT 8903A
~i4-T58 OUTSIDE COl!T A I l!MEl~T
- <s61434sl 31
- i)
- 3l4-T58 NOTE 7 /
559 (S6 I -1/~!
A
-/
"-IOTE. L___~
~--
1s5 1991 11/,SPL -
5 i\\1 I
R:CS LOOP I
COLO LEG
-....-11
~ H..,__~
~OA 8810A @
1'1% C58 DR FE 0MB T5T 92.4 s 6 ~/4
,---r--r-*1 39-B 3/4-T58 S6 TO TEST L Jl,IE HOR
[\\JOTE 2 F,.
927 RO IJOTE 555 20
- sGI 199513) 42 CHARG I 1,1G PUJvlPS DISCH
~---< 08 45B-B IIOTE I 8 r,JOTE I 8 8969 I -T58 Pl 155 S6 2075 I
A 9
293-E O
I 43 I 16-E 34-U)CAL S6 I 9 7 8 4
680/,A A
4 6M58FN NOTE I 9
~
~110T E 9 IIOTE 13 44 45
~
RE!vlOVABLE CAP
NOTE II
~
AUX BLDG SUHP & PUHR FROM COl~T A I l~lvlEII T SPRAY TEST L I 11 E 3 9-E I 2 DISCH FROH BORIC ACID BLEl~DER 41B-E 08 (s2I 61 512) 46 V r7 G-0283 D
L I 965 47 S2-3/4 r1~WATER FILL
\\.* G-0283 G-0283 G-0283 SI PUMPS 58_0 ~..-__J_-=-::-r::-:--::--:r:sc:--__j__h-______
=r--LJ-("=s=2=l2=6=4=1l=4)::__--1, S2 2064 2 4 X2 8972 2-T58 3 9-A I 9 DISCH FROM REACTOR COOL DOWIJ TA 111<
S2 I 896 8 25-B I 3 DISCH FROM REFUEL[l,IG +
WTR PURIFICATIOI~
PUMP DISCH NOTE 8
?/4" G-0283 8975 4 x42D N
,J) 48 TO CASK WASHDOWIJ
- AREA, FUEL HA~IDL I IIG BLDG FLOOR ORA I IJ 30 II VEIH 811-,
6 x4 REFUEL I 1,1 G WATER STORAGE TANK 2-I TAIW BY PG&E DC-66307 I - I 29 DC-663071 - I 34 ITEM 81 SPEC 8729 111 49 8970A 1/,
T58 PG
@t(D(171A-AI 33)
LT 920
,;-i TV&V
)4-T58 6 I 1/:U T58 co 0
8907 l~OTE I 4 PRIMARY M WATER STOR l93 TAl'W 2-1 1-EI 1167 i'IOTE 2 FX 926 w
=
co
(_/)
8820 3-C58 S6 282 3 S6 283 3 A
B
~98~2 ~M 4>< 3 r.,
~* 4 _1 880 I B
~H58FII IIOT E I 9 (S6 I :1/4)
S6 2033 4 S6 I 919 4 I /
I/
/ 4 X / 16 NOTE 22 3/
I 1
/4 X /4 TO PLA~IT YARD ORA I 11 [\\JORHAL OPERATION
,-8902B P' ~14-T58
,(
~ ~-----
(S6I2573 I I)
S 7 0 2 6 /16 B
!SE r 3/4-TS A
5 E
2 8900B I '/rC58 TEST COIHI &
ACCUM FILL LIIIE AL TERl,IATE 89036
~;4 - T 5 8 CDtill C 1 I 3 IO 309 1S6 7178 3/4 S2 4256 14 3 8-C r'lf--____L---~..
=i::==:;::::=:::::-----i.J (s6 I3/4)
<32A-B I
r 9)
CLOSED D RA 111 NOTES:
I. DELETED DR IIOTE 23 3 I I 3~
L'J m TC
- 2.
FLOWW METER [ l,JG OR IF I CE DURING PRE OPERATIONAL TO VERIFY FLOW(IE@
TESTIIIG
- 3. DELETED
- 4.
F'G ll~DICATES F'G&E CO SCF'OE
- 5.
VALVES ARE SET TO BALANCE ECCS INJECTION FLOWS AND TO PREVENT RUHR RUNOUT, THEN CONTROLLED IN THE THROTTLED POSITimL~
- 6. ALL WESTINGHOUSE ITEH NUHBERS IN SIS ARE SHOWN WITHOUT PREFIX PG&E SI
- 7. SPECIAL LIIIE IIJSULATIOI~ IIICLUOIIJG CHECK~
- 8.
WHE~I WATER IS cmnAH[I.JATEO BLl~ID FLA~IIIGE Ci)
WITH HOSE BIBB HUST BE INSTALLED DRAINING TO MISC EQUIP DRAIN TANK 0-1 ---
- 9. VELAII Hl,JF VALVE (42,43-D)(42,43-C)(45-B,C)
- 10. CHAIN OPERATED<TI)G)
I I. EHBEDDED PI PE, 1\\10 L ll1E IJUHBER (ED 31-P:OIC 3 Size 331 VE 3/4" z
- 12. FIELD TO l~ISTALL BOSS PER FIG-343, DWG 053093 DC-~OOa.'-1-7.3-97
~
~
- 13.
~;~
ANCHOR/DARL[l,JG, MODEL 1878, BOLTED BOl,IIET, GATE VALVE, PO" 722739 ITEH 3, DC-6006473-7 ~
I 4. BL All K FL ANGE I S PG & E P I PE CODE CLASS " C ", (IE[>
15, DELETED
- 16. DELETED
- 17. DELETED
- 18. I" Al!CHOR DARLl~IG GLOBE VALVE 1878, STOCK CODE 94-3771 DC-6006473-157 ~
I 9, 14 " A 11 CHOR DAR L I NG GLOBE VALVE, STOCK CODE 9 4 - 2 8 2 0 DC-6006473-97 ( "2-D!C) <
e5-1>B) 8803A 4 -GH58FI~
,(298-El32) r:,
S6 I
TE!='
i._56-2323-7'4 S6 8803B 4 -GM58FII L!.J D
-E:
NOTE?>
n 8859B 56 1974 4
- 'I
_!_ o N
w f-0 z Zl:18 D :3Z)
Sbil9754
~~x1--S6-2329-3/4 IIOTE I 9
- 20. THE RESTRICTING ORIFICE ASSEMBLY CONSISTS OF A PRESSURE RED UC I IIG OR IF I CE (PRO), A SWAGE TYPE REDUCER All A FLOW BAFFLE PER DRAWING DC 663230-409 (el-D1C)
- 21. f4" AIJCHOR DARLil!G GLOBE VALVE, S/C 95-2755, DC 6011930-79.~
- 22.
FOR LINE 7026-1/15:
PG&E S-SPEC WITH THE FOLLOWING SPECIAL REQUIREMENTS:
-TUBll,JG SIZE SHALL BE 1/15" OD WITH WALL THICKI\\JESS OF 0. 020"
-SEAMLESS STAINLESS STEEL TUBING MATERIAL GRADE TP304 HAY BE SUBSTITUTED FOR GRADE TP316, ALL OTHER REQUIREMENTS OF S-SPEC SHALL APPLY.
-LEl~GTH OF Lil!E 7026-/15:
24 FEET+./-
2 FEET (REF.
DCP N-50631 i
- 23. MECHANICAL TRAVEL STOP INSTALLED ON VALVE 310 TO LIMIT OPEN STEM TRAVEL
- 1. REF:
DWG" 60 I 1930-140, PAGE 3 )~~___,,~,
- 24. co1n1ECTIO~I POI~IT FOR FLEX EQUIPIIEJ,n<J:2) ~
1-0_2_-0_3 _-_2_0_1 _5+-lv_J N_R_U+-F_x_C_2-+K_, _J D--=-3 +-fl _::_O_T_R-=E-=Q-=U-=I_R-=E=-=D'---P-=E=-R-'----C=-F_3=-=-..:_I =-0 =-5-1-------+-------+------ R EV I S E D P E R DD N - 2
- I 3 2 4 L,i, It:.
_:'v./f.l l \\J
~'hi,~ l:.', "l r,'.J!\\_ ::.IE, l ii::.::.-:
e,z4 8 C4'l.
S2 26 I I 2 39-C I 2 REFUEL WATER SUPPLY TO CONTAINMENT SPRAY PPS SUCTION HEATER
'5 e C 146 A :I 3805A 8-GM42FB a
C, q)
Ill 0
'I;)
148 A~
~
8805B 8-GM42F6
( s I l/4)
TYP 2 SAMPLE SJl,tl<
I EL. I 00' AUX, BLDG, I S2-l"-J*
l"x0,065 S.S STR TIJBil!Gr 463
- .'52-1"
,-;iV 1LOOR ORA I 1,1 o/4X4'2D S2 221 18 (ill)
REFUEL WATER SUPPLY TO RESIDUAL HEAT REMOVAL PUMPS 308B-E 32 303B-E 32 8860
- /4 - T 5 8 8807B 4-GH42FB 58-E HISC EO T 4 r,DRTf'.O-I Sll9718IIIP)
REF.
DWG.
DC 663216-63 SAFETY I llJ, PUHR 2-I SUCT I 01.1 LJI\\J IT DI ABLO CAI\\IYOI\\J SAFETY DRAW I 1,1G 08009 POWER PLAI\\JT
[I\\IJECTIOI\\I S(STEM SHEET PAGE REV 0
E D
C B
A