APEPLICABIMLIT SURVEILLANCE REQUIREMENTS or other specified conditions 4.0.1 Surveillance Requirements shall be met during the MODES In the Surveillance. Failure to in the Applicability for individual LCOs, unless otherwise stated the performance of the meet a Surveillance, whether such failure is experienced during to meet the LCO.

Surveillance or between performances of the Surveillance, shall be failure to meet the LCO interval shall be failure Failure to perform a Surveillance within the specified on inoperable except as provided in 4.0.3. Surveillances do not have to be performed equipment or variables outside specified limits.

surveillance 4.0.2 Each Surveillance Requirement shall be performed within the specified percent of the specified interval with a maximum allowable extension not to exceed twenty-five surveillance interval.

within its specified interval, then 4.0.3 If it is discovered that a Surveillance was not performedmay be delayed, from the time of compliance with the requirement to declare the LCO not met interval, whichever is discovery, up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or up to the limit of the specified surveillance A risk the Surveillance.

greater. This delay period is permitted to allow performance of than 24 hours and the risk evaluation shall be performed for any Surveillance delayed greater impact shall be managed.

must immediately be If the Surveillance Is not performed within the delay period, the LCO declared not met, and the applicable ACTION(s) must be entered.

Surveillance is not met, the When the Surveillance is performed within the delay period and the ACTION(s) must be entered.

LCO must immediately be declared not met, and the applicable shall not be made 4.0.4 Entry into an OPERATIONAL MODE or other specified condition Condition for Operation unless the Surveillance Requirement(s) associated with the Limiting specified. This as otherwise have been performed within the stated surveillance interval or to comply with modes as required provision shall not prevent passage through or to operational ACTION requirements.

3/4 0-2 AMENDMENT NO. 62-9, 187 WATERFORD UNIT 3

APPLICABIhLI SURVEILLANCE RE.UIREMENTS (Continued.

Class 1, 4.0.5 Surveillance Requirements for inservice Inspection and testing of ASME Code 2, and 3 components shall be applicable as follows:

a. Inservice inspection of ASME Code Class 1, 2. and 3 components and inservice in testing ASME Code Class 1, 2 and 3 pumps and valves shall be performed and Pressure Vessel Code and accordance with Section Xl of the ASME Boiler where applicable Addenda as required by 10 CFR 50, Section 50.55a(g), except by the Commission pursuant to 10 CFR 50, specific written relief has been granted Section 50.55a(g)(6)(i).
b. Surveillance intervals specified in Section XI of the ASME Boiler and Pressure testing Vessel Code and applicable Addenda for the inservice inspection and Vessel Code and applicable activities required by the ASME Boiler and Pressure Addenda shall be applicable as follows in these Technical Specifications:

ASME Boiler and Pressure Vessel Code and applicable Required frequencies Addenda terminology for for performing inservice inservice inspection and inspection and testing testlng actlvl~tes activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Yearly or annually At least once per 366 days

c. The provisions of Specification 4.0.2 are applicable to the above required frequencies for performing inservice inspection and testing activities.
d. Performance of the above inservice inspection and testing activities shall be in addition to other specified Surveillance Requirements.
e. Nothing in the ASME Boiler and Pressure Vessel Code shall be construed to supersede the requirements of any Technical Specification.

AMENDMENT NO. 187 WATERFORD UNIT 3 314 0-3