Book 7 of 17 Final Status Survey Final Report Phase IV Appendix A6 Survey Unit Release Record 9106-0006, Discharge Canal November 2006

CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0006 Prepared By: /*,_ I ._ Date:

FS er

/

Reviewed By: Date:

F,Sp-ngineer ,

Approved By: C ,'. .41,, , Date: /1 YIP6 Technical Support Manager Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION ..................................................... 3
2. CLASSIFICATION BASIS ............................................................. 3
3. DATA QUALITY OBJECTIVES (DQO) ........................................ 5
4. SURVEY DESIGN ............................................................................ 8
5. SURVEY IMPLEMENTATION .................................................. 11
6. SURVEY RESULTS ....................................................................... 12
7. QUALITY CONTROL ................................................................... 13
8. INVESTIGATIONS AND RESULTS ............................................ 14
9. REMEDIATION AND RESULTS ................................................ 15
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ....... 15
11. DATA QUALITY ASSESSMENT (DQA) .................................... 15
12. ANOM ALIES .................................................................................. 16
13. CONCLUSIONS .............................................................................. 16
14. ATTACHM ENTS ............................................................................ 17 Attachment 1 - Figures (6 pages including cover)

Attachment 2 - Sample and Statistical Data (273 pages including covers)

Revision 0

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0006 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 9,716 m 2 (2.40 acres) of water covered sediment in an area located approximately 0.68 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)

(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes. The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0005 is to the north (called north as orientated with the north to south flow of the Connecticut River), land surface area Survey Unit 9521 is to the east, Discharge Canal Survey Unit 9106-0007 is to the south and Discharge Canal area 9106-0012 (formerly a part of 9530) is to the west. The survey unit comprises the canal sediments to the deeper of three (3) feet or the original construction depth and it extends up the canal banks to the mean high water level.

The reference coordinates associated with this survey unit are E026 through E032 by S120 through S133 (refer to License Termination Plan Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0006 as Class 2 in May 2006.

The "ClassificationBasis Summary" conducted for this survey unit consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial CharacterizationReport" and the "Historic Site Assessment (HSA) Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

e) Formal or informal interviews with cognizant personnel.

A review of the 10CFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. Several events indicated the potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side system leakage events, Revision 0 3 Revision 0 3

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD contamination found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment. The sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86). None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.

Additional information was provided by several historical documents, including the "Results ýof Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00). These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.

A final characterization was performed by Site Closure personnel in April and May of 2004. Six (6) sediment samples were taken. All of the samples were analyzed by gamma spectroscopy, Sr-90 and tritium. Additionally, Hard-to-Detect (HTD) analyses were performed on one (1) sample. The radionuclides of concern identified in the sample data for FSS planning purposes were Cesium-137, Cobalt-60 and Sr-90. All other positively detected isotopes could be screened out based on the 5%/10% rule of Section 5 of the LTP. The statistics for each of the radionuclides of concern are listed in Table 1.

  • Table -asic StatisticalQuanties fd for-(s137 a 99fmin 0 the et~r:; Characterization Sm-Nu paalttrCs137 (pCi/~g) I ~Co'-6ý (jpCig)~I Sr-90.(pCi/g)

Minimum Value: -7.59E-04 8.61E-03 1.14E-02 Maximum Value: 2.22E-01 6.14E-01 7.16E-02 Mean: 1.29E-01 2.76E-01 4.17E-02 Median: 1.64E-01 2.73E-01 3.94E-02 Standard Deviation: 1.02E-01 2.67E-01 2.50E-02 NOTE: The Operational DCGLs are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve 19 mrem/yr TEDE The FSS Engineer performed a visual inspection and walk-down during April 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 2 (refer to Section 3).

Revision 0 4

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, 'Preparation of Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0006 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL),

for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.

As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario. Consequently, the soil DCGLs are directly applied to the canal sediment media.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

Revision 0 5 Revision 0 5

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD HTotal=Hsoil (sediment) + HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey unit is not affected by existing or future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from existing and future groundwater is zero (0) mrem/yr TEDE, based on field data.

Equation 2:

19 mrem/yr1 otaff 19 mrem/yrsoil+ 0 mrem/yrExisting GW+ 0 mrem/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in nineteen (19) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Revision 0 6 Revision 0 6

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Table 2 - Radionjuclide Specific Base Case Soil DCGL, Operational C s and Required Minimum Detectable Concentrations Radionuclide (*'Base Case Soil Operational pCGL Requi red MDCo H-3 4.12E+02 3.13E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-0I Mn-54 1.74E+OI 1.32E+01 6.96E-01 Fe-55 2.74E+04 2.08E+04 1.1 OE+03 Co-60 3.81E+00 2.90E+00 1.52E-01 Ni-63 7.23E+02 5.49E+02 2.89E+01 Sr-90 1.55E+00 1.1 8E+00 6.20E-02 Nb-94 7.12E+00 5.41E+00 2.85E-0I Tc-99 1.26E+OI 9.58E+00 5.04E-01 Ag- 108m 7.14E+00 5.43E+00 2.86E-0I Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-01 Eu- 152 1.01E+01 7.68E+00 4.04E-0I Eu-154 9.29E+00 7.06E+00 3.72E-0I Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+OI 2.25E+01 1.18E+00 Pu-239/240 2.67E+O I 2.03EE+01 1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 (5) 2.58E+01 1.96E+01 1.03E+00 Cm-243/244 2.90E+O I 2.20E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. The radiological data that was used to support the DQO process, was provided by the characterization surveys performed in 2004 and 2006, as discussed in Section 2. Cs-137, Co-60 and Sr-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Sr-90 are provided in Table 1.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Revision 0 7 Revision 0 7

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Detectable Concentration (<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans".

This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined. Consequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE, as discussed in Section 2 of this Release Record.

The DQO process determined that Cs-137, Co-60 and Sr-90 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Sr-90) were considered in the survey design.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Sr-90 concentrations in sediment and soil were ascertained by direct analysis.

Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%

for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected. This process was applied to analysis data for this survey unit.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determinationof the Number of Samples for Final Revision 0 8 Revision 0 8

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting relative shift was 2.7. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

'TaIbie3 -apeMeasur~emeiutlocations with Associated GPS Coordinates"-

Designation Northing -Easting 9106-0006-001F 235490.83 671656.84 9106-0006-003F 235412.87 671611.83 9106-0006-004F 235412.87 671701.85 9106-0006-005F 235412.87 671791.88 9106-0006-006F 235412.87 671881.90 9106-0006-007F 235334.91 671746.86 9106-0006-008F 235334.91 671836.89 9106-0006-009F 235334.91 671926.91 9106-0006-01 OF 235334.91 672016.94 9106-0006-011 F 235334.91 672106.96 9106-0006-012F 235334.91 672196.99 9106-0006-014F 235256.94 672061.95 9106-0006-015F 235256.94 672151.98 9106-0006-017F 235206.44 672120.54 9106-0006-018F 235420.43 671845.27 9106-0006-019F 235364.94 671732.17 9106-0006-020F 235253.59 672053.62 Revision 0 9 Revision 0 9

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate some samples due to the inaccessibility of the original sample locations. Grid Sample locations 9106-0006-002F and 9106-0006-013F were found to be on dry land. This was also the case for biased sample location 9106-0006-16F. Consequently, the grid sample locations were randomly re-located using the VSP software to two (2) new locations designated as 9106-0006-019F and 9106-0006-020F. Biased sample 9106-0006-016F was relocated to location 9106-0006-018F, a location that also was in the vicinity of the outfall that was of interest.

Three (3) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2) samples were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RAND" functions. In addition, the two (2) samples, which were determined to contribute the greatest dose based on gamma only analyses, were also selected for HTD analyses. Coincidentally, one of these (sample 9106-0006-010F) was selected in the earlier random selections, so only one additional sample was analyzed based on the gamma results The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, "

included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the 5% requirement.

The LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.

Revision 0 10 Revision 0 10

DISCHARGE CANAL SURVEY UNIT 9 106-0006 RELEASE RECORD survey unit Based on AutoCAD-LT and Visual 9,716 m2 Land Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was 0.183 the LBGR was set to 0.5 Measurements to maintain Relative Shift in the range of I and 3, Relative Shift was 2.7 Grid Spacing 27.4 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve ten (10) mrem/yr TEDE 0.62 pCi/g Sr-90 Operational 6.01 pCi/g Cs-137 To achieve nineteen (19) mrem/yr DCol 2.90 pCi/g Co-60 TEDE (2)to demonstrate compliance with DCGL 1.18 pCi/g Sr-90 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 6.01 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.90 pCi/g Co-60 criteria for a Class 2 survey unit Level 1.18 pCi/g Sr-90 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Surveys, Inc.

(OSI) of Old Saybrook, Connecticut. Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments. Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample Revision 0 I1I Revision 0 11

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD locations were accomplished using a GPS interfaced with a navigation and data logging system.

After extraction, water was drained from above the sample by drilling holes above the sediment. The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.

The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Three (3) samples (9106-0006-005F, 9106-0006-009F and 9106-0006-010F) were selected for HTD radionuclide analysis by the off-site laboratory The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0006-007F and 9106-0006-018F for "split sample" analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy. Sr-90 was analyzed by gas flow proportional counting. All analyses were performed to the required MDC.

Cesium-137 was identified in ten (10), Co-60 was identified in nine (9) and Sr-90 in one (1) of the fifteen (15) samples.

Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.

The off-site laboratory also processed three (3) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. Two (2) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one (1)

Revision 0 12 Revision 0 12

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.

None of the sample results exceeded the Operational DCGL or required further investigation. A summary of the sample results is provided in Table 5.

____ Table 5-. Sum mary of S~oil Sampleh Reut a m11pl e Cs-1~37 Co!-60() sr9 Fric~tion

Operational: the O ofDCGL*

Number~~ pc!g~ p 'lg Cilg prto-At((I 9106-0006-001 F -7.55E-04 -3.31 E-03 5.3 7E-04 -8.12E-04 9106-0006-003F 1.70E-01 7.22E-01 1.45E-02 2.90E-01 9106-0006-004F 9.60E-02 4.38E-02 4.27E-03 3.47E-02 9106-0006-005F 4.09E-0 I 1.94E+00 1.95E-02 7.54E-0 I 9106-0006-006F 1.30E-01 2.41 E-01 7.50E-04 1.05E-01 9106-0006-007F 1.38E-02 1.58E-02 -1.OOE-02 -7.30E-04 9106-0006-008F 2.95E-01 6.35E-01 4.02E-03 2.71 E-01 9106-0006-009F 2.26E-01 1.02E-0 I 7.88E-03 7.95E-02 9106-0006-01 OF 5.20E-01 6.3 1E-01 7.15E-03 3.1 0E-O1 9106-0006-01 IF 3.12E-03 4.70E-02 1.49E-02 2.94E-02 9106-0006-012F 2.71 E-02 6.08E-03 -2.02E-03 4.89E-03 9106-0006-014F 1.79E-01 4.86E-0 1 -1.04E-03 1.96E-01 9106-0006-015F 3.43E-01 2.21E-01 -3.81E-03 1.30E-01 9106-0006-01 9F -2.82E-02 -1.34E-02 1.67E-03 -7.90E-03 9106-0006-020F 1.28E-02 7.34E-02 -5.59E-03 2.27E-02 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve 19 mrem/yr TEDE (2) These values represent only the identified radionuclides Two (2) biased samples were required by the sample plan. These samples were designated as sample locations 9106-0006-017F and 9106-0006-018F. The sample results are presented in Table 6 below.

9106-0006-017F 2.34E-02 1.44E-02 6.14E-03 9106-0006-018F 5.69E-02 1.20E-01 2.23E-03 I 5.27E-02 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE

7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Two (2) of the samples were selected for analysis, which Revision 0 13 Revision 0 13

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " For one (1) of the split-sample comparisons (9106-0005-01 8F/S), Cs- 137 was found to not meet the comparison criterion; however, this nuclide may not be present in a particulate form and, therefore, is not necessarily an indicator of a non-homogenous mixing of the soil matrix. K-40, a natural radioisotope, was also found not to be present at an acceptable level of agreement, so the comparison issue was dispositioned to the Condition Report (CR) process, to resolve the issue. The issue is not believed to affect the outcome of the FSS for the following reasons:

  • The other quality control split sample comparison (9106-0006-007F/S) was found to meet the agreement criteria.

" The balance of quality control samples for the discharge canal area numbering some thirty-six (36) samples were found to be in acceptable agreement.

" The sediment samples were found to be at approximately fifteen (15) percent of the nineteen (19) mrem/yr DCGL.

The sample analysis vendor, General Engineering Laboratories (GEL) -

Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

8. INVESTIGATIONS AND RESULTS One (1) sample result was found to exceed the design DCGL, but was below the nineteen (19) mrem/yr operational DCGL, as specified in Table 4. Confirmatory samples were collected to determine the extent of contamination. The area extent was bounded by taking four (4) confirmatory samples, one (1) in each direction of the compass, two (2) meters distant from the elevated sample location. The gamma spectroscopy and Sr-90 results are included in Table 10.

005B 1.14E-01 4.36E-01 5.01E-03 1.94E-01 005F 005C 3.17E-01 8.21E-01 7.38E-03 3.83E-01 005D 1.03E-01 1.48E-01 4.46E-04 7.67E-02 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE Revision 0 14 Revision 0 14

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The confirmatory results demonstrate that no measurements exceed the nineteen (19) mrem/yr operational DCGL, indicating that no further actions are warranted.

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE as discussed in Section 2 of this Release Record.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.

Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

Revision 0 15 Revision 0 15

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The range of the data, about 3.8 standard deviations, was not unusually large.

The difference between the mean and median was 34% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 2.14.

All data, assessments, and graphical representations are provided in Attachment 2.

12. ANOMALIES The anomalies associate with the disagreement between the field splits at sample location (9106-0006-018F) has been discussed in Section 7. The issue was referred to Condition Report (CR-06-0223).

No other anomalies were identified for this survey unit.

13. CONCLUSIONS Survey Unit 9106-0006 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

The sample data passed the Sign Test. The null hypothesis was rejected.

Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as Class 2.

The dose contribution from sediment is 2.8 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from existing groundwater sources is bounded by zero (0) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including that from sediment, will not exceed 2.8 mrem/yr Total Effective Dose Equivalent (TEDE).

Revision 0 16 Revision 0 16

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD

14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 - Sample and Statistical Data Revision 0 17 Revision 0 17

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 1 Figures (5 pages)

- Wa -%I/

-Skme wall 0 70 140

- Feet ComdiMN aM in NAD27CbGf~

Connecticut Yankee Atomic Power Company Date By Rev.

Site Map with Reference to Survey Unit 9106-0006 ^1 71 e 1 0

14-0 70 140 Fedt 7onnecticut River Connecicut Yankee Atomic PowerCompany Date By Rev.

9106-000 FinalStaus SurveyDesign fl#- I7ul V 0 0

qa-P~d Wetfra 0.014

-0.03 -S&bMn 1.02-0.001 -0.00SqLmw 0700 0 &M*OCU 1409 (0 00056 005)

,ýB 5106-00490 6 FialSttu 00 Stronium-0 PotingPlotI ureyDeig Oter206 E.NSOW

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2 Sample and Statistical Data

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2a Sample Data (253Pages)

Table of Contents General Narrative ................................ 1 Chain of Custody and Supporting Documentation ........... 4 Radiological A nalysis .......................................................... 11 Sam ple Data Sum m ary ...................................................... 31 Q uality C ontrol D ata ........................................................... 73

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 162850 SDG: MSR #06-0687 June 7, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 12, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample 1D Client Sample ID 162850001 9106-0006-01 IF 162850002 9106-0006-014F 162850003 9106-0006-015F 162850004 9106-0006-018F 162850005 9106-0006-018FS 162850006 9106-0006-019F 162850007 9106-0006-OO1F 162850008 9106-0006-003F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712 - Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171 ° Fa2(843) 766-1178

  • www.gel.com

Sample ID Client Sample ID 162850009 9106-0006-008F 162850010 9106-0006-009F 162850011 9106-0006-01OF 162850012 9106-0006-020F 162850013 9106-0006-004F 162850014 9106-0006-005F 162850015 9106-0006-006F 162850016 9106-0006-007F 162850017 9106-0006-007FS 162850018 9106-0006-012F 162850019 9106-0006-017F Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Seventeen sediment samples were analyzed for FSSGAM and Sr-90.

Two sediment samples were analyzed for FSSALL.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Packagee:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fa3(843) 766-1178
  • www.gel.com

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major HelhPyis rcdr P-GG-510-03Atcmn -C-01Mjo Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Name: Haddam Neck Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z 301D. [F 14 D. [] 7 D.

Samples Shipped Via:

[ Fed Ex E UPS E1 Hand nI Other Bill ofLading #

7cf2O0- 5clgo -6 5T-

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Project Name: Haddam Neck Decommissic Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z 30 D. E] 14 D. [] 7 D.

)le Z LTP QA El Radwaste QA [] Non QA Samples Shipped Via:

Z Fed Ex LI UPS LI Hand Date/Time LI Other Bill of Lading #f 712 7*to- 4611

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00332 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lah,,Use Only",,

Contact Name & Phone: C rnom ents:  ! ..

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <'

843 556 8171. Attn. Cheryl Jones "

Priority: [ 30 D. [ 14 D, E 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Saple. 1.

9106-0006-004F 4/28/06 12:46 SE C BP x x Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP x x Transferred from COC 2006-00317 9106-0006-012F 5/01/06 13:40 SE C BP x x Transferred from COC 2006-00317 9106-0006-017F 5/01/06 14:03 SE C BP x X Transferred from COC 2006-00317

- - 7t*  :.' '.:  :

NOTES: PO #: 002332 MSR #: 06-C41 SSWP# NA Z LTP QA E1 Radwaste QA [I Non QA Samples Shipped Via: Iberna Container Z Fed Ex T~mpif'Deg.~

El uPs

[] Hand Custo* y Sealed?

1) Relinquished By Date/Time 2) Received By ate/Time custlboy sealIntact.

E] Other , *y, N, .2  %:

3) Relinquished By Date/Time 4) Received By bate/Time Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OO1 Figure 1. Sample Check-in List.

Date/rime Received': CI *c)IO. @Yi7 (-)

SDG#: AA

,, o (o--h Work Order Number:- / - . "

ShippingCcftitainerID *-' (OID+/- ,2Lt Chainof Custody# .S ' CO vi(' StKfe -(.

1. Custody Seals oxi shipping container intact?

-Yes [ No

2. Custody Seals dated and signed?

Yes[ ].No

3. Chain-of-Custody record present?

Yes(P)No I I

4. Cooler temperature .oc_.
5. .Vermiculite/packing materials is:
  • 6. t Wet
6. -,";Number of samples in shipping Container:. Dry Dr (,

. . "* 4u.-...~L(OvZ nyýf-.* .

'Qf', . .

7. Sample holding times exceeded?

Yes[]No 4*

-8. Samples have:

-~tape hazard labels

  • 2custody seals --. appropriate sample labels
9. Samples are:

-*.&,in good condition -leaking

  • ....broken  : "" have ir bubbles
10. Were any anomalies identified in sample receipt? Yes [] No .

11" * .Description of.anomalies (include sample numbe. .. '

Sample. CustodianlLaboratory: . ...

Le- ...

r; Data . .

Telephoned to:______________________

.,* .- . ~ o n1__ .__,__. _. ... ... .

1 4 -'." / " . . *8

SAMPLE RECEIPT & REVIEW FORM 0%'NTORIV'3 ýs PMuse onl Client: Cý n IVfl 1 SDG/ARCOC/Work Order: /C z3Z-, /(.,,ZT5 Date Received: 97/ PM(A) Review (oture mo-eoulltnI are resolved prior to siping):

Received By: C lAev I c k Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)

I Shipping containers received intact ircil Applicable: seals broken damaged container leaking container other (describe) 1and sealed? -;

Samples requiring cold / Circle Coolant I ice bags blue ice dry ice other describe) 2 preservation within (4 +/ 2 C)?

Record preservation method. 0 C_

3 Chain of custody documents e" C-0 OU o-xiCtVU-included with shipment?V sealed? 1 ircppablesalbkci tu-"

i:*, ycabe*alb -q'0(*',.

cn2-'*l damaged container k-aing container -

1 Sample containers intact and 5 Samples requiring chemical Sample ID's. containers affected and observed pH:

5reservation at proper pH?

6 VOA vials free of headspace Sample ID's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) 1 8 Samples received within holding Id's and tests affeacd:

time? ______________________________

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles? I 0 Date & time on COC match date Sample ID's affected:

& time on bottles? I Number of containers received Sample ID's affected:

match number indicated on COC?

COC form is properly signed in l , r Ct)G. "4iL, YCULC , s . C1 1i 2 relinquished/received sections?

  • Air Bill ,Tracking #'s, &

Additional Comments

, Ccv(U"- I ux.-c (- *._'-

>- RSORADReceipt_ #

U *If > x2 area background is observed on samples identified as "non-Suispected Hazard Information e H rm S5-= regulated/non-radioactive", contact the Radiation Safety group for further

__ __ FZ investigation.

Radiological Classification? Maximum Counts Observed*:

PCB Regulated? V Comments:

Shipped as IX) 1Hazardous

  • Material? If yes, contact Waste "/ Hazard Class Shipped:

MManager or ESH Manager.

PM (or PMA) review of Hazard classification: Initials Date:

a 9

SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM

-F.ed F, o-kO: C00- con4=0.t, (p(tr)(r, Loi5S 105 A 00,336 C (o0) s,( Y 4l 5 7oýýl-.v hatd n..

bUsfcEd 15 a i~ '"c_

fm) w~ Alu3.J+'v c~ " _ __ _ __J_ _

10

RADIOLOGICAL ANALYSIS 11

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 162850 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 533471 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01 OF 1201101117 Method Blank (MB) 1201101118 162485017(9106-0005-005F) Sample Duplicate (DUP) 1201101119 162485017(9106-0005-005F) Matrix Spike (MS) 1201101120 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12

Ouality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 13

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 533472 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01 OF 1201101121 Method Blank (MB) 1201101122 162485017(9106-0005-005F) Sample Duplicate (DUP) 1201101123 162485017(9106-0005-005F) Matrix Spike (MS) 1201101124 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.

14

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 533473 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 15

Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-OIOF 1201101125 Method Blank (MB) 1201101126 162485017(9106-0005-005F) Sample Duplicate (DUP) 1201101127 162485017(9106-0005-005F) Matrix Spike (MS) 1201101128 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis The tracer yield for sample 1201101127 (9106-0005-005F) was recounted due to poor resolution.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 529777 Prep Batch Number: 529739 17

Sample ID Client ID 162850001 9106-0006-01 IF 162850002 9106-0006-014F 162850003 9106-0006-015F 162850004 9106-0006-018F 162850005 9106-0006-018FS 162850006 9106-0006-019F 162850007 9106-0006-001F 162850008 9106-0006-003F 162850009 9106-0006-008F 162850010 9106-0006-009F 162850011 9106-0006-01 OF 162850012 9106-0006-020F 162850013 9106-0006-004F 162850014 9106-0006-005F 162850015 9106-0006-006F 162850016 9106-0006-007F 162850017 9106-0006-007FS 162850018 9106-0006-012F 162850019 9106-0006-017F 1201092335 Method Blank (MB) 1201092336 162850001(9106-0006-011 F) Sample Duplicate (DUP) 1201092337 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162850001 (9106-0006-01 IF).

QC Information 18

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate did not meet the relative percent difference requirement for Bi-212, Ra-226 and Th-208, however they do meet the relative error ratio requirement with value of 2.26 for Bi-212, 1.99 for Ra-226 and 2.72 for Th-208.

Qualifier information 19

Qualifier Reason Analyte Sample UI Data rejected due to interference. Europium-155 162850007 162850009 162850014 162850016 162850017 Manganese-54 162850017 UI Data rejected due to low abundance. Bismuth-214 1201092336 Cesium- 134 162850004 162850005 162850006 162850007 162850009 162850012 162850013 162850015 162850016 162850017 162850019 1201092336 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 534447 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 20

Sample ID Client ID 162850001 9106-0006-01 IF 162850002 9106-0006-014F 162850003 9106-0006-015F 162850004 9106-0006-018F 162850005 9106-0006-018FS 162850006 9106-0006-019F 162850007 9106-0006-001F 162850008 9106-0006-003F 162850009 9106-0006-008F 162850010 9106-0006-009F 162850011 9106-0006-OIOF 162850012 9106-0006-020F 162850013 9106-0006-004F 162850014 9106-0006-005F 162850015 9106-0006-006F 162850016 9106-0006-007F 162850017 9106-0006-007FS 162850018 9106-0006-012F 162850019 9106-0006-017F 1201103430 Method Blank (MB) 1201103431 162850003(9106-0006-015F) Sample Duplicate (DUP) 1201103432 162850003(9106-0006-015F) Matrix Spike (MS) 1201103433 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC 21

The following sample was used for QC: 162850003 (9106-0006-015F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 162850010 (9106-0006-009F) and 162850011 (9106-0006-010F) were recounted due to high MDAs. Sample 1201103433 (LCS) was recounted due to low/high recovery.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The blank, 1201103430 (MB), did not meet the detection limit due to keeping the blank volume consistent with the other sample aliquots. All other samples met the detection limits.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 531704 22

Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-OIOF 1201096867 Method Blank (MB) 1201096868 162583001(NOL-02-02-005-F-S) Sample Duplicate (DUP) 1201096869 162583001(NOL-02-02-005-F-S) Matrix Spike (MS) 1201096870 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 23

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 531618 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01 OF 1201096631 Method Blank (MB) 1201096632 163173001 (9304-0000-063RACR) Sample Duplicate (DUP) 1201096633 163173001(9304-0000-063RACR) Matrix Spike (MS) 1201096634 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry 24

All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 25

Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 531622 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01 OF 1201096644 Method Blank (MB) 1201096645 163173001 (9304-0000-063RACR) Sample Duplicate (DUP) 1201096646 163173001(9304-0000-063RACR) Matrix Spike (MS) 1201096647 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.

26

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid - 1 to 2 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 531705 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01OF 1201096877 Method Blank (MB) 1201096878 162583001(NOL-02-02-005-F-S) Sample Duplicate (DUP) 1201096879 162583001(NOL-02-02-005-F-S) Matrix Spike (MS) 1201096880 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 11.

27

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201096877 (MB), 162850010 (9106-0006-009F) and 162850011 (9106-0006-01OF) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 28

Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 534984 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-01OF 1201104745 Method Blank (MB) 1201104746 163173001 (9304-0000-063RACR) Sample Duplicate (DUP) 1201104747 163173001 (9304-0000-063RACR) Matrix Spike (MS) 1201104748 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

29

Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date: 1gL 4ie1--

30

SAMPLE DATA

SUMMARY

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-0687 GEL Work Order: 162850 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the reporting limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-01 IF Proiect: YANK01204 Sample ID: 162850001 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 42.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.908 +/-0.297 0.130 +/-0.297 0.273 pCi/g MJH1 06/05/06 2340 529777 1 Americium-2 4 1 U -0.0354 +/-0.0542 0.0432 +/-0.0542 0.0886 pCi/g Bismuth-212 U 0.292 +/-0.518 0.297 +/-0.518 0.620 pCi/g Bismuth-214 0.606 +/-0.164 0.0639 +/-0.164 0.133 pCi/g Cesium-134 U 0.0697 +/-0.0502 0.0444 +/-0.0502 0.0927 pCi/g Cesium-137 U 0.00312 +/-0.0432 0.0361 +/-0.0432 0.0754 pCi/g Cobalt-60 U 0.047 +/-0.0461 0.0412 +/-0.0461 0.0875 pCi/g Europium-152 U 0.0184 +/-0.100 0.0827 +/-0.100 0.171 pCi/g Europium- 154 U -0.039 +/-0.132 0.108 +/-0.132 0.229 pCi/g Europium-155 U 0.0871 +/-0.0891 0.0735 +/-0.0891 0.151 pCi/g Lead-212 0.878 +/-0.106 0.0522 +/-0.106 0.107 pCi/g Lead-214 0.438 +/-0.111 0.0614 +/-0.111 0.127 pCi/g Manganese-54 U 0.029 +/-0.0728 0.039 +/-0.0728 0.0816 pCi/g Niobium-94 U-0 1.000518 +/-0.0403 0.0333 +/-0.0403 0.0696 pCi/g Potassium-40 16.0 +/-1.34 0.318 +/- 1.34 0.686 pCi/g Radium-226 0.606 +/-0.164 0.0639 +/-0.164 0.133 pCi/g Silver-108ni U -0.0164 +/-0.0372 0.0294 +/-0.0372 0.0611 pCi/g Thallium-208 0.422 +/-0.0918 0.0358 +/-0.0918 0.0747 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00244 +/-0.00747 0.00618 +/-0.00747 0.0128 pCi/g BXF1 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0853 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OIF Project: YANK01204 Sample ID: 162850001 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%/-,125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-014F Project: YANK01204 Sample ID: 162850002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 31%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.02 +/-0.295 0.127 +/-0.295 0.254 pCi/g MJH1 06/05/06 1716 529777 1 Americium-241 U 0.0071 +/-0.136 0.0958 +/-0.136 0.192 pCi/g Bismuth-212 1.12 +/-0.502 0.248 +/-0.502 0.496 pCi/g Bismuth-214 0.548 +/-0.173 0.0714 +/-0.173 0.143 pCi/g Cesium-134 U 0.0645 +/-0.0518 0.0479 +/-0.0518 0.0957 pCi/g Cesium-137 0.179 +/-0.0779 0.0345 +/-0.0779 0.0689 pCi/g Cobalt-60 0.486 +/-0.119 0.0396 +/-0.119 0.0791 pCi/g Europium-152 U 0.00309 +/-0.142 0.0883 +/-0.142 0.177 pCi/g Europium-154 U 0.0957 +/-0.139 0.124 +/-0.139 0.248 pCi/g Europium-155 U 0.00678 +/-0.105 0.0839 +/-0.105 0.168 pCi/g Lead-212 0.568 +1-0.151 0.0586 +/-0.151 0.117 pCi/g Lead-214 0.767 +/-0.176 0.0653 +/-0.176 0.131 pCi/g Manganese-54 U -0.0368 +/-0.046 0.0349 +/-0.046 0.0698 pCi/g Niobium-94 U 0.0384 +/-0.0389 0.0353 +/-0.0389 0.0705 pCi/g Potassium-40 12.9 +/-1.66 0.282 +/-1.66 0.564 pCi/g Radium-226 0.548 +/-0.173 0.0714 +/-0.173 0.143 pCi/g Silver-108m U -0.00315 +/-0.0373 0.0302 +/-0.0373 0.0603 pCi/g Thallium-208 0.249 +/-0.0836 0.0351 +/-0.0836 0.0702 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.00104 +/-0.00595 0.00504 +/-0.00595 0.0105 pCi/g BXF1 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-014F Proiect: YANK01204 Sample ID: 162850002 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 84 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analv-id Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-015F Proiect: YANKO 1204 Sample ID: 162850003 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 20.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 0.650 +/-0.227 0.0899 +/-0.227 0.180 pCi/g MJH1 06/05/06 1716 529777 1 Americium-241 U 0.0935 +/-0.109 0.091 +/-0.109 0.182 pCi/g Bismuth-212 0.475 +/-0.429 0.155 +/-0.429 0.309 pCi/g Bismuth-214 0.435 +/-0.114 0.0453 +/-0.114 0.0905 pCi/g Cesium-134 U 0.0461 +/-0.0384 0.0306 +/-0.0384 0.0611 pCi/g Cesium-137 0.343 +/-0.0587 0.0222 +/-0.0587 0.0444 pCi/g Cobalt-60 0.221 +/-0.0669 0.0215 +/-0.0669 0.0429 pCi/g Europium-152 U -0.0894 +/-0.0921 0.054 +/-0.0921 0.108 pCi/g Europium-154 U - -0.00226 +/-0.0861 0.0725 +/-0.0861 0.145 pCi/g Europium-155 U 0.0459 +/-0.0737 0.0674 +/-0.0737 0.135 pCi/g Lead-212 0.650 +/-0.0936 0.0352 +/-0.0936 0.0703 pCi/g Lead-214 0.500 +/-0.121 0.0424 +/-0.121 0.0848 pCi/g Manganese-54 U-C 1.000117 +/-0.0312 0.0235 +/-0.0312 0.0469 pCi/g Niobium-94 U -0.0154 +/-0.029 0.0208 +/-0.029 0.0416 pCi/g Potassium-40 10.6 +/-1.19 0.199 +/-1.19 0.398 pCi/g Radium-226 0.435 +/-0.114 0.0453 +/-0.114 0.0905 pCi/g Silver-108m U - 0.00346 +/-0.0254 0.0213 +/-0.0254 0.0426 pCi/g Thallium-208 0.223 +/-0.0637 0.0243 +/-0.0637 0.0485 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U - 0.00381 +/-0.00625 0.00542 +/-0.00626 0.0113 pCi/g BXF1 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-015F Proiect: YANK01204 Sample ID: 162850003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORGES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018F Proiect: YANKO 1204 Sample ID: 162850004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 21.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 1.49 +/-0.159 0.0473 +/-0.159 0.0996 pCi/g MJH1 06/05/06 1918 529777 1 Americium-241 U -0.0253 +/-0.103 0.0885 +/-0.103 0.182 pCi/g Bismuth-212 0.829 +/-0.238 0.110 +/-0.238 0.231 pCi/g Bismuth-214 0.901 +/-0.086 0.028 +/-0.086 0.0582 pCi/g Cesium-134 UUI 0.00 +/-0.0254 0.0201 +/-0.0254 0.0417 pCi/g Cesium-137 0.0569 +/-0.0266 0.0162 +/-0.0266 0.0336 pCi/g Cobalt-60 0.120 +/-0.0383 0.0138 +/-0.0383 0.0294 pCi/g Europium-152 U 0.0162 +/-0.0445 0.0407 +/-0.0445 0.084 pCi/g Europium-154 U 0.0154 +/-0.0549 0.0466 +/-0.0549 0.0982 pCi/g Europium-155 U 0.0679 +/-0.0806 0.0521 +/-0.0806 0.107 pCi/g Lead-212 1.58 +/-0.0659 0.024 +/-0.0659 0.0494 pCi/g Lead-214 1.06 +/-0.0843 0.0272 +/-0.0843 0.0564 pCi/g Manganese-54 U 0.0075 +/-0.0214 0.0134 +/-0.0214 0.0282 pCi/g Niobium-94 U - -0.0096 I +/-0.0163 0.0132 +/-0.0163 0.0275 pCi/g Potassium-40 17.4 +/-0.786 0.133 +/-0.786 0.284 pCi/g Radium-226 0.901 +/-0.086 0.028 +/-0.086 0.0582 pCi/g Silver-108m U 0.00355 +/-0.0145 0.013 +/-0.0145 0.0269 pCi/g Thallium-208 0.529 +/-0.043 0.0139 +/-0.043 0.029 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00223 +/-0.00863 0.00716 +/-0.00863 0.0148 pCi/g BXF1 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018F Project: YANKO 1204 Sample ID: 162850004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 86 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018FS Project: YANKO 1204 Sample ID: 162850005 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 16.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.50 +/-0.193 0.0586 +/-0.193 0.124 pCi/g MJH1 06/07/06 1941 529777 1 Americium-241 U 0.0164 +/-0.0929 0.0802 +/-0.0929 0.164 pCi/g Bismuth-212 1.06 +/-0.269 0.130 +/-0.269 0.273 pCi/g Bismuth-214 0.811 +/-0.0973 0.0345 +/-0.0973 0.0719 pCi/g Cesium-134 UUI 0.00 +/-0.0365 0.0256 +/-0.0365 0.0532 pCi/g Cesium-137 U 0.0247 +/-0.023 0.0183 +/-0.023 0.0384 pCi/g Cobalt-60 0.0993 +/-0.0313 0.0164 +/-0.0313 0.0354 pCi/g Europium-152 U 0.0167 +/-0.0526 0.0474 +/-0.0526 0.098 pCi/g Europium-154 U -0.0286 +/-0.0637 0.0524 +/-0.0637 0.112 pCi/g Europium-155 U 0.00 +/-0.0557 0.053 +/-0.0557 0.108 pCi/g Lead-212 1.33 +/-0.0744 0.0276 +/-0.0744 0.0568 pCi/g Lead-214 1.03 +/-0.107 0.0316 +/-0.107 0.0656 pCi/g Manganese-54 U 0.0176 +/-0.0296 0.0187 +/-0.0296 0.0392 pCi/g Niobium-94 U -0.00731 +/-0.0193 0.0165 +/-0.0193 0.0345 pCi/g Potassium-40 11.3 +/-0.853 0.149 +/-0.853 0.325 pCi/g Radium-226 0.811 +/-0.0973 0.0345 +/-0.0973 0.0719 pCi/g Silver-108m U 0.0175 +/-0.0179 0.0163 +/-0.0179 0.0338 pCi/g Thallium-208 0.467 +/-0.0504 0.0178 +1-0.0504 0.0372 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00318 +/-0.0075 0.00614 +/-0.0075 0.0129 pCi/g BXFI 06/02/062018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-0211B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018FS Project: YANK01204 Sample ID: 162850005 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-019F Project: YANK01204 Sample ID: 162850006 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 34%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.743 +/-0.243 0.0838 +/-0.243 0.180 pCi/g MJH1 06/06/06 0018 529777 1 Americium-241 0.190 +/-0.136 0.0836 +/-0.136 0.174 pCi/g Bismuth-212 0.577 +/-0.509 0.177 +/-0.509 0.378 pCi/g Bismuth-214 0.438 +/-0.106 0.0462 +/-0.106 0.0973 pCi/g Cesium-134 UUI 0.00 +/-0.056 0.0325 +/-0.056 0.0685 pCi/g Cesium-137 U -0.0282 +/-0.028 0.0208 +/-0.028 0.0444 pCi/g Cobalt-60 U -0.0134 +/-0.0294 0.0227 +/-0.0294 0.0501 pCi/g Europium-152 U -0.106 +/-0.0751 0.0531 +/-0.0751 0.112 pCi/g Europium-154 U -0.0332 +/-0.0894 0.0705 +/-0.0894 0.154 pCi/g Europium-155 U 0.00 +/-0.0752 0.0641 +/-0.0752 0.132 pCi/g Lead-212 0.907 +1-0.115 0.0322 +/-0.115 0.0669 pCi/g Lead-214 0.546 +/-0.133 0.0396 +/-0.133 0.0832 pCi/g Manganese-54 U 0.0171 +/-0.0293 0.0245 +/-0.0293 0.0523 pCi/g Niobium-94 U 0.0284 +/-0.0406 0.0216 +/-0.0406 0.0458 pCi/g Potassium-40 14.5 +/- 1.48 0.227 +/-1.48 0.502 pCi/g Radium-226 0.438 +/-0.106 0.0462 +/-0.106 0.0973 pCi/g Silver-108m U -0.021 +/-0.0229 0.0179 +/-0.0229 0.0378 pCi/g Thallium-208 0.291 +/-0.0645 0.0219 +/-0.0645 0.0466 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00167 +/-0.007 0.00579 +/-0.007 0.0121 pCi/g BXFI 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-019F Project: YANK01204 Sample ID: 162850006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 84 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-001F Proiect: YANKO 1204 Sample ID: 162850007 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 22.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSSGAM & ALL FSS Actinium-228 1.47 +/-0.330 0.114 +/-0.330 0.242 pCi/g MJH1 06/07/06 1942 529777 1 Americium-2 4 1 U 0.0322 +1-0.0555 0.0457 +/-0.0555 0.0937 pCi/g Bismuth-212 1.38 +/-0.604 0.224 +/-0.604 0.475 pCi/g Bismuth-214 0.999 +1-0.151 0.0546 +/-0.151 0.115 pCi/g Cesium-134 UUI 0.00 +/-0.0794 0.0426 +/-0.0794 0.089 pCi/g Cesium-137 U-0 0.000755 +/-0.039 0.0336 +/-0.039 0.0705 pCi/g Cobalt-60 U - -0.00331 +/-0.0373 0.0313 +/-0.0373 0.0675 pCi/g Europium-152 U - -0.00151 +/-0.083 0.0715 +/-0.083 0.149 pCi/g Europium-154 U 0.0214 +/-0.108 0.093 +/-0.108 0.199 pCi/g Europium-155 UUI 0.00 +/-0.131 0.0701 +/-0.131 0.144 pCi/g Lead-212 1.43 +/-0.0989 0.0413 +/-0.0989 0.0856 pCi/g Lead-214 1.07 +/-0.144 0.0506 +/-0.144 0.106 pCi/g Manganese-54 U 0.0269 +/-0.0563 0.0317 +/-0.0563 0.0671 pCi/g Niobium-94 U -0.0231 +/-0.0315 0.0258 +/-0.0315 0.0545 pCi/g Potassium-40 18.5 +/-1.23 0.229 +/-1.23 0.506 pCi/g Radium-226 0.999 +/-0.151 0.0546 +/-0.151 0.115 pCi/g Silver-108m U 0.00689 +/-0.0322 0.0276 +/-0.0322 0.0575 pCi/g Thallium-208 0.524 +/-0.0835 0.0286 +/-0.0835 0.0603 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U C.000537 +/-0.00804 0.00672 +/-0.00804 0.0141 pCi/g BXFI 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OO1F Proiect: YANKO 1204 Sample ID: 162850007 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 78 (25%/.-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-003F Proiect: YANKO 1204 Sample ID: 162850008 Client ID: YANKOOl Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 24.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,Solid-FSS GAM & ALL FSS Actinium-228 0.846 +/-0.189 0.0734 +/-0.189 0.156 pCi/g MJH1 06/07/06 1942 529777 1 Americium-241 U -0.0495 +/-0.0853 0.0742 +/-0.0853 0.153 pCi/g Bismuth-212 0.789 +/-0.301 0.153 +/-0.301 0.323 pCi/g Bismuth-214 0.475 +/-0.0869 0.0338 +/-0.0869 0.0714 pCi/g Cesium-134 U 0.0421 +/-0.027 0.0246 +/-0.027 0.0517 pCi/g Cesium-137 0.170 +/-0.0418 0.0201 +/-0.0418 0.0423 pCi/g Cobalt-60 0.722 +/-0.0687 0.0165 +/-0.0687 0.0364 pCi/g Europium-152 U --0.00848 +/-0.0547 0.0472 +/-0.0547 0.0985 pCi/g Europium-154 U 0.00912 +/-0.0708 0.0597 +/-0.0708 0.129 pCi/g Europium-155 U 0.0826 +/-0.0933 0.0474 +/-0.0933 0.0979 pCi/g Lead-212 0.800 +/-0.0645 0.0282 +/-0.0645 0.0583 pCi/g Lead-214 0.619 +/-0.0893 0.0349 +/-0.0893 0.0728 pCi/g Manganese-54 U 0.0175 +/-0.026 0.0181 +/-0.026 0.0386 pCi/g Niobium-94 U 0.0158 +/-0.0373 0.017 +/-0.0373 0.0359 pCi/g Potassium-40 12.5 +/-0.946 0.139 +/-0.946 0.312 pCi/g Radium-226 0.475 +/-0.0869 0.0338 +/-0.0869 0.0714 pCi/g Silver-108m U 0.0119 +/-0.0191 0.0169 +/-0.0191 0.0353 pCi/g Thallium-208 0.304 +/-0.0506 0.0169 +/-0.0506 0.0358 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.0145 +/-0.020 0.0198 +/-0.020 0.0439 pCi/g BXFI 06/03/06 0903 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-003F Project: YANKO 1204 Sample ID: 162850008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-008F Proiect: YANK01204 Sample ID: 162850009 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 36.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actiniumn-228 0.967 +/-0.174 0.0502 +/-0.174 0.104 pCi/g MJH1 06/07/06 2201 529777 1 Americium-241 U 0.0139 +/-0.0656 0.0488 +/-0.0656 0.0996 pCi/g Bismuth-212 0.752 +/-0.257 0.110 +/-0.257 0.227 pCi/g Bismuth-214 0.659 +/-0.102 0.0267 +/-0.102 0.0551 pCi/g Cesium-134 UUI 0.00 +/-0.0255 0.0174 +/-0.0255 0.036 pCi/g Cesium-137 0.295 +/-0.0447 0.0133 +/-0.0447 0.0275 pCi/g Cobalt-60 0.635 +/-0.0601 0.0139 +/-0.0601 0.0293 pCi/g Europium-152 U -0.0188 +/-0.0427 0.0349 +/-0.0427 0.0717 pCi/g Europiurn-154 U 0.0145 +/-0.0503 0.0415 +/-0.0503 0.087 pCi/g Europium-155 UU1 0.00 +/-0.0655 0.0379 +/-0.0655 0.0773 pCi/g Lead-212 1.02 +/-0.0932 0.0194 +/-0.0932 0.0398 pCi/g Lead-214 0.812 +/-0.105 0.025 +/-0.105 0.0514 pCi/g Manganese-54 U 0.000653 +/-0.018 0.015 +/-0.018 0.0311 pCi/g Niobium-94 U 0.00784 +/-0.0151 0.013 +/-0.0151 0.0268 pCi/g Potassium-40 16.9 +/-1.20 0.107 +/-1.20 0.229 pCi/g Radium-226 0.659 +/-0.102 0.0267 +/-0.102 0.0551 pCi/g Silver-108m U 0.00921 +/-0.0145 0.0121 +1-0.0145 0.025 pCi/g Thallium-208 0.294 +/-0.0457 0.0147 +/-0.0457 0.0304 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00402 +/-0.0162 0.0172 +/-0.0162 0.0388 pCi/g BXFI 06/03/06 0904 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-008F Proiect: YANKO 1204 Sample ID: 162850009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC

.2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-009F Project: YANKO 1204 Sample ID: 162850010 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 28.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.03 +/-0.065 0.0367 +/-0.065 0.161 pCi/g LCW1 05/30/06 1156 533471 1 Curium-2 4 2 U 0.00 /-0.0725 0.00 +1-0.0725 0.100 pCi/g 4 0.0368 +/-0.0652 0.161 pCi/g Curium-2 3/244 U 0.0246 /-0.0651 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.015 +/-0.0648 0.0505 +/-0.0649 0.186 pCi/g LCWI 05/30/06 2129 533472 2 Plutonium-239/240 U 0.00 +/-0.0614 0.00 +/-0.0614 0.0848 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -1.47 +/-7.89 6.69 +/-7.89 13.9 pCi/g LCWI 06/03/06 0646 533473 3 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.716 +/-0.183 0.0686 +/-0.183 0.148 pCi/g MJHI 06/05/06 2158 529777 4 Americium- 2 4 1 U -0.0471 +/-0.110 0.0853 +/-0.110 0.177 pCi/g Bismuth-212 0.609 +/-0.323 0.121 +/-0.323 0.263 pCi/g Bismuth-214 0.393 + /-0.0985 0.0311 +/-0.0985 0.0666 pCi/g Cesium-134 U 0.0223 + /-0.0286 0.0231 +/-0.0286 0.0494 pCi/g Cesium-137 0.226 + /-0.0658 0.0156 +/-0.0658 0.0339 pCi/g Cobalt-60 0.102 + /-0.0359 0.0208 +/-0.0359 0.0458 pCi/g U -0.0219 /-0.0519 0.0425 +/-0.0519 0.0901 pCi/g Europium-152 4 Europium-15 4

U -0.0215 + /-0.0704 0.0575 +/-0.0704 0.126 pCi/g Europium-155 U 0.0924 -+

/-0.0906 0.0494 +/-0.0906 0.103 pCi/g Lead-212 0.660 + /-0.0803 0.0262 +/-0.0803 0.0548 pCi/g Lead-214 0.545 +/-0.097 0.033 +/-0.097 0.0696 pCi/g Manganese-54 U 0.0121 +/-0.022 0.0194 +/-0.022 0.0419 pCi/g Niobium-94 U 0.00483 4-/-0.0185 0.0161 +/-0.0185 0.0346 pCi/g Potassium-40 11.2 +/-1.20 0.154 +/-1.20 0.349 pCi/g Radium-226 0.393 4

/-0.0985 0.0311 +/-0.0985 0.0666 pCi/g Silver-108m U -0.01 +-/-0.0175 0.015 +/-0.0175 0.0319 pCi/g Thallium-208 0.197 + -- 0.0465 0.018 +/-0.0465 0.0385 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90 , solid - 0.025 pCi/g 90 pCi/g BXFI 06/05/062116 534447 5 Strontium- U 0.00788 +/ -0.00962 0.00977 +/-0.00962 0.0208 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - I to 2 pCi/g Tritium U -0.17 +/-0.518 0.438 +/-0.518 0.895 pCi/g NXPI 06/03/06 0204 531705 6 51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 tnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-009F Project: YANKO 1204 Sample ID: 162850010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.133 +/-0.102 0.0817 +/-0.102 0.169 pCi/g ATH2 06/04/06 0142 534984 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 15.5 +/-22.8 16.4 +/-22.8 34.4 pCi/g SLNI 05/29/06 1615 531618 9 Liquid Scint Ni63, Solid ALL FSS Nickel-63 U -4.06 +/-3.35 2.89 +/-3.35 5.89 pCi/g SLNI 05/27/06 0221 531622 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0504 +/-0.251 0.209 +/-0.251 0.432 pCi/g SXEI 05/30/062305 531704 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-1, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 90 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 74 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 93 (25/,-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid - 0.025 pCi/g 74 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 83 (15%-125%)

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-009F Proiect: YANK01204 Sample ID: 162850010 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25/,-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certifieate nf Analwviq j*A*r Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-010F Proiect: YANK01204 Sample ID: 162850011 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 28.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0541 +/-0.0719 0.00 +/-0.0723 0.0675 pCi/g LCW1 05/30/06 1155 533471 1 Curium-242 U 0.0217 +/-0.0576 0.0326 +/-0.0577 0.143 pCi/g Curium-243/244 U -0.012 +/-0.0517 0.0402 +/-0.0517 0.148 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.00 +/-0.0691 0.00 +/-0.0691 0.0955 pCi/g LCW1 05/30/06 2129 533472 2 Plutonium-239/240 U 0.0352 +/-0.069 0.00 +/-0.0692 0.0955 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -7.44 +/-7.73 6.81 +/-7.77 14.2 pCi/g LCW1 06/03/06 0702 533473 3 Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.673 +/-0.182 0.0618 +/-0.182 0.132 pCi/g MJHI 06/06/06 0657 529777 4 Americium-241 U 0.0697 +/-0.0798 0.0686 +/-0.0798 0.141 pCi/g Bismuth-212 0.401 +/-0.307 0.137 +/-0.307 0.289 pCi/g Bismuth-214 0.472 +/-0.0976 0.0323 +/-0.0976 0.0679 pCi/g Cesium-134 U 0.0462 +/-0.039 0.0234 +/-0.039 0.0493 pCi/g Cesium-137 0.520 +/-0.0547 0.0156 +/-0.0547 0.0332 pCi/g Cobalt-60 0.631 +/-0.0688 0.0167 +/-0.0688 0.0365 pCi/g Europium-152 U -0.00528 +/-0.051 0.0441 +1-0.051 0.0919 pCi/g Europium-154 U 0.00414 +/-0.0655 0.0558 +/-0.0655 0.120 pCi/g Europium-155 U 0.00807 +/-0.0505 0.0451 +1-0.0505 0.0929 pCi/g Lead-212 0.596 +/-0.0621 0.0256 +/-0.0621 0.0531 pCi/g Lead-214 0.541 +/-0.0872 0.0305 +/-0.0872 0.0637 pCi/g Manganese-54 U 0.0149 +/-0.0228 0.0201 +/-0.0228 0.0425 pCi/g Niobium-94 U 0.00627 +/-0.0196 0.0172 +/-0.0196 0.0361 pCi/g Potassium-40 10.1 +/-0.812 0.149 +/-0.812 0.329 pCi/g Radium-226 0.472 +/-0.0976 0.0323 +/-0.0976 0.0679 pCi/g Silver-108m U -0.00817 +/-0.0176 0.0146 +/-0.0176 0.0306 pCi/g Thallium-208 0.208 +/-0.0559 0.0168 +/-0.0559 0.0355 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid - 0.025 pCi/g Strontitum-90 U 0.00715 +)-0.00615 0.00584 +/-0.00616 0.0127 pCi/g BXF1 06/05/06 2117 534447 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - I to 2 pCi/g Tritium U 0.118 +/-0.491 0.410 +/-0.491 0.837 pCi/g NXPI 06/03/06 0338 531705 6 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-01OF Proiect: YANKO 1204 Sample ID: 162850011 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.161 +/-0.109 0.0867 +/-0.109 0.179 pCi/g ATH2 06/04/06 0345 534984 7 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 12.3 +/-21.9 .16.0 +/-21.9 33.7 pCi/g SLNI 05/29/06 1632 531618 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.00 +/-4.14 3.47 +/-4.14 7.07 pCi/g SLNI 05/27/06 0322 531622 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0163 +/-0.271 0.227 +/-0.271 0.469 pCi/g SXE1 05/30/062321 531704 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep f Ash Soil Prep, GL-RAD-A-02e B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-l, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 87 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 61 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 94 (25%/q- 125%)

Carrier/Tracer Recovery GFPC, Sr90, solid - 0.025 pCi/g 100 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 71 (15%-125%)

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OIOF Project: YANK01204 Sample ID: 162850011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 86 (25%/-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 69 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORGES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-02OF Project: YANKO 1204 Sample ID: 162850012 Client ID: YANKOO1 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 28.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganvma,Solid-FSS GAM & ALL FSS Actinium-228 0.844 +/-0.136 0.0584 +/-0.136 0.125 pCi/g MJH1 06/06/06 0657 529777 1 Americium-241 U 0.0189 +/-0.128 0.0762 +/-0.128 0.156 pCi/g Bismuth-212 0.614 +/-0.281 0.110 +/-0.281 0.236 pCi/g Bismuth-214 0.558 +/-0.0775 0.0315 +/-0.0775 0.0663 pCi/g Cesiumn-134 UUI 0.00 +/-0.0331 0.0228 +/-0.0331 0.048 pCi/g Cesium-137 U 0.0128 +/-0.0392 0.0172 +/-0.0392 0.0362 pCi/g Cobalt-60 0.0734 +/-0.0396 0.0183 +/-0.0396 0.0395 pCi/g Europium-152 U 0.0104 +/-0.0537 0.0461 +/-0.0537 0.0959 pCi/g Europium-154 U 0.0357 +/-0.0762 0.0576 +/-0.0762 0.124 pCi/g Europium- 155 U 0.00 +/-0.0589 0.0534 +/-0.0589 0.110 pCi/g Lead-212 0.809 +/-0.0588 0.028 +/-0.0588 0.0577 pCi/g Lead-214 0.678 +/-0.0754 0.0328 +/-0.0754 0.0682 pCi/g Manganese-54 U --0.00567 +/-0.0206 0.0172 +/-0.0206 0.0365 pCi/g Niobium-94 U --0.00247 +/-0.0182 0.0155 +/-0.0182 0.0328 pCi/g Potassium-40 13.8 +/-0.850 0.143 +/-0.850 0.316 pCi/g Radium-226 0.558 +/-0.0775 0.0315 +/-0.0775 0.0663 pCi/g Silver--108m U (0.000505 +/-0.0175 0.0147 +/-0.0175 0.0308 pCi/g Thallium-208 0.223 +/-0.0431 0.0165 +/-0.0431 0.0347 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U - -0.00559 +/-0.0104 0.0131 +/-0.0104 0.030 pCi/g BXF1 06/03/06 0904 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-020F Project: YANKO 1204 Vol. Recv.: YANKOOI Sample ID: 162850012 Client ID:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 94 (25 %-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-004F Proiect: YANKO 1204 Sample ID: 162850013 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 26%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GanimaSolid-FSSGAM & ALL FSS Actinium-228 0.972 +/-0.265 0.0864 +/-0.265 0.187 pCi/g MJHI 06/07/06 1944 529777 1 Americium-241 U 0.00641 +/-0.0402 0.0335 +/-0.0402 0.0691 pCi/g Bismuth-212 0.604 +/-0.395 0.204 +/-0.395 0.435 pCi/g Bismuth-214 0.723 +/-0.124 0.0437 +/-0.124 0.0933 pCi/g Cesium-134 UUI 0.00 +/-0.0507 0.0309 +/-0.0507 0.0661 pCi/g Cesium-137 0.096 +/-0.057 0.0264 +/-0.057 0.0562 pCi/g Cobalt-60 U 0.0438 +/-0.0445 0.0276 +/-0.0445 0.0608 pCi/g Europium- 152 U -0.0561 +/-0.0636 0.0536 +/-0.0636 0.113 pCi/g Europium-154 U -0.0703 +/-0.0848 0.064 +/-0.0848 0.143 pCi/g Europium-155 U 0.00 +/-0.0611 0.0566 +/-0.0611 0.117 pCi/g Lead-212 0.912 +/-0.0781 0.0347 +/-0.0781 0.0721 pCi/g Lead-214 0.716 +/-0.117 0.0425 +/-0.117 0.0895 pCi/g Manganese-54 U 0.00792 +/-0.0311 0.0264 +/-0.0311 0.0568 pCi/g Niobium-94 U 0.00282 +/-0.0277 0.0236 +/-0.0277 0.0502 pCi/g Potassium-40 11.5 +/-1.08 0.174 +/- 1.08 0.402 pCi/g Radium-226 0.723 +/-0.124 0.0437 +/-0.124 0.0933 pCi/g Silver-108m U -0.0131 +/-0.0229 0.0193 +/-0.0229 0.0409 pCi/g Thallium-208 0.300 +/-0.0565 0.0262 +/-0.0565 0.0557 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00427 +/-0.015 0.0158 +/-0.015 0.0358 pCi/g BXFI 06/03/06 0904 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-004F Proiect: YANK01204 Sample ID: 162850013 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 82 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Proiect: YANK01204 Sample ID: 162850014 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 15.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.02 +/-0.249 0.0817 +/-0.249 0.172 pCi/g MJHl 06/06/06 0916 529777 1 Americium-241 U -0.0104 +/-0.116 0.0918 +/-0.116 0.189 pCi/g Bismuth-212 0.766 +/-0.337 0.182 +/-0.337 0.379 pCi/g Bismuth-214 0.842 +/-0.119 0.0381 +/-0.119 0.0796 pCi/g Cesium-134 U 0.00 +/-0.0423 0.0291 +/-0.0423 0.0607 pCi/g Cesium-137 0.409 +/-0.0547 0.0203 +/-0.0547 0.0425 pCi/g Cobalt-60 1.94 +/-0.162 0.0189 +/-0.162 0.041 pCi/g Europium-152 U -0.0232 +/-0.0626 0.0519 +/-0.0626 0.108 pCi/g Europium-154 U 0.0616 +/-0.0724 0.0653 +/-0.0724 0.139 pCi/g Europium-155 UUI 0.00 +/-0.0885 0.0533 +/-0.0885 0.110 pCi/g Lead-212 1.15 +/-0.112 0.0295 +/-0.112 0.0609 pCi/g Lead-214 0.982 +/-0,133 0.0367 +/-0.133 0.0761 pCi/g Manganese-54 U 0.000439 +/-0.0292 0.0244 +/-0.0292 0.0511 pCi/g Niobium-94 U -0.00364 +/-0.0232 0.0196 +/-0.0232 0.0409 pCi/g Potassium-40 12.8 +/- 1.20 0.145 +/-1.20 0.322 pCi/g Radium-226 0.842 +/-0.119 0.0381 +/-0.119 0.0796 pCi/g Silver-108m U -0.0143 +/-0.0202 0.0174 +/-0.0202 0.0362 pCi/g Thallium-208 0.319 +/-0.0531 0.021 +/-0.0531 0.0438 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0195 +/-0.0222 0.0214 +/-0.0222 0.0475 pCi/g BXFI 06/03/06 1010 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANK01204 Sample ID: 162850014 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-006F Project: YANK01204 Sample ID: 162850015 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 21.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS Actinium-228 1.76 +/-0.238 0.0865 +/-0.238 0.181 pCi/g MJHI 06/06/06 0916 529777 1 Americium-241 U -0.0427 +/-0.0394 0.0364 +/-0.0394 0.0741 pCi/g Bismuth-212 1.15 +/-0.400 0.173 +/-0.400 0.361 pCi/g Bismuth-214 1.23 +/-0.120 0.0445 +/-0.120 0.0924 pCi/g Cesium-134 UUI 0.00 +/-0.0387 0.0341 +/-0.0387 0.0706 pCi/g Cesium-137 0.130 +/-0.0546 0.026 +/-0.0546 0.0539 pCi/g Cobalt-60 0.241 +/-0.0752 0.0248 +/-0.0752 0.0525 pCi/g Europium-152 U -0.0519 +/-0.0676 0.0583 +/-0.0676 0.120 pCi/g Europium-154 U -0.0354 +/-0.0796 0.0664 +/-0.0796 0.141 pCi/g Europium-155 U 0.00 +/-0.106 0.0577 +/-0.106 0.118 pCi/g Lead-212 1.76 +/-0.0823 0.0341 +/-0.0823 0.0701 pCi/g Lead-214 1.30 +/-0.114 0.0426 +/-0.114 0.0879 pCi/g Manganese-54 U 0.0312 +/-0.0479 0.0271 +/-0.0479 0.0564 pCi/g Niobium-94 U 0.003 +/-0.0259 0.0229 +/-0.0259 0.0475 pCi/g Potassium-40 11.4 +/-0.851 0.193 +/-0.851 0.416 pCi/g Radium-226 1.23 +/-0.120 0.0445 +/-0.120 0.0924 pCi/g Silver-108m U -0.0111 +/-0.0244 0.0208 +/-0.0244 0.043 pCi/g Thallium-208 0.544 +/-0.0672 0.0236 +/-0.0672 0.0491 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00075 +1-0.0155 0.0173 +/-0.0155 0.0389 pCi/g BXFI 06/03/06 1010 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-006F Proiect: YANK01204 Sample ID: 162850015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC[MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007F Project: YANK01204 Sample ID: 162850016 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 24.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.883 +/-0.156 0.0431 +/-0.156 0.0917 pCi/g MJHI 06/06/06 0917 529777 1 Americium-241 U -0.0496 +/-0.0591 0.0507 +/-0.0591 0.104 pCi/g Bismuth-212 0.618 +/-0.216 0.104 +/-0.216 0.219 pCi/g Bismuth-214 0.548 +/-0.0897 0.0246 +/-0.0897 0.0516 pCi/g Cesium-134 UUI 0.00 +/-0.0306 0.0171 +/-0.0306 0.0358 pCi/g Cesium-137 U 0.0138 +/-0.0171 0.0143 +/-0.0171 0.0299 pCi/g Cobalt-60 U 0.0158 +/-0.0167 0.0149 +/-0.0167 0.0317 pCi/g Europium-152 U 0.0103 +/-0.041 0.0357 +/-0.041 0.0743 pCi/g Europium-154 U -0.0167 +/-0.0529 0.0424 +/-0.0529 0.0903 pCi/g Europium-155 UUI 0.00 +/-0.0724 0.0418 +/-0.0724 0.0859 pCi/g Lead-212 0.850 +/-0.0823 0.0214 +/-0.0823 0.0441 pCi/g Lead-214 0.640 +/-0.0887 0.0241 +/-0.0887 0.0503 pCi/g Manganese-54 U - 0.00885 +/-0.0179 0.0148 +/-0.0179 0.0312 pCi/g Niobium-94 U 0.00505 +/-0.0151 0.0133 +/-0.0151 0.0278 pCi/g Potassium-40 14.7 +/-1.11 0.120 +/-1.11 0.260 pCi/g Radium-226 0.548 +/-0.0897 0.0246 +/-0.0897 0.0516 pCi/g Silver-108m U -0.0163 +/-0.0138 0.0109 +/-0.0138 0.0229 pCi/g Thallium-208 0.253 +/-0.0445 0.0136 +/-0.0445 0.0285 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.01 +/-0.0125 0.0165 +/-0.0125 0.0372 pCi/g BXF1 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007F Project: YANKO 1204 Sample ID: 162850016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com CprtiffirntP nf Ann J- vdie Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007FS Proiect: YANKO 1204 Sample ID: 162850017 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 42.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM& ALL FSS Actinium-228 0.869 +/-0.188 0.0734 +/-0.188 0.160 pCi/g MJHI 06/07/06 1946 529777 1 Americium-241 U - 0.00837 +/-0.0303 0.0252 +/-0.0303 0.0522 pCi/g Bismuth-212 0.699 +/-0.376 0.151 +/-0.376 0.328 pCi/g Bismnuth-214 0.660 +/-0.110 0.0369 +/-0.110 0.0792 pCi/g Cesium-134 UUI 0.00 +/-0.0383 0.0291 +/-0.0383 0.0621 pCi/g Cesium-137 U 0.0098 +/-0.0244 0.0211 +/-0.0244 0.0455 pCi/g Cobalt-60 U 0.0327 +/-0.0271 0.0259 +/-0.0271 0.057 pCi/g Europium- 152 U -0.0156 +/-0.0607 0.049 +/-0.0607 0.104 pCi/g Europium-154 U 0.0509 +/-0.0832 0.0738 +/-0.0832 0.162 pCi/g Europium-155 UUI 0.00 +/-0.0737 0.0371 +/-0.0737 0.0775 pCi/g Lead-212 0.968 +/-0.0713 0.0265 +/-0.0713 0.0556 pCi/g Lead-214 0.689 +/-0.110 0.0335 +/-0.110 0.0712 pCi/g Manganese-54 UUI 0.00 +/-0.0239 0.0231 +/-0.0239 0.0497 pCi/g Niobium-94 U -0.0162 +/-0.0253 0.0199 +/-0.0253 0.0425 pCi/g Potassium-40 12.8 +/-1.08 0.217 +/-1.08 0.484 pCi/g Radium-226 0.660 +/-0.110 0.0369 +/-0.110 0.0792 pCi/g Silver-108m U 0 .000843 +/-0.0202 0.0175 +/-0.0202 0.0373 pCi/g Thallium-208 0.261 +/-0.0517 0.0205 +/-0.0517 0.0439 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0067 +/-0.0171 0.0175 +/-0.0171 0.0401 pCi/g BXFI 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007FS Project: YANK01204 Sample ID: 162850017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Fracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25- 125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has beerl confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

U1 Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-012F Proiect: YANK01204 Sample ID: 162850018 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 24.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.800 +/-0.102 0.0385 +/-0.102 0.0815 pCi/g MJI-1 06/06/06 1110 529777 1 Americium-241 U 0.0264 +/-0.0785 0.0714 +/-0.0785 0.147 pCi/g Bismuth-212 0.580 +/-0.210 0.0896 +/-0.210 0.188 pCi/g Bismuth-214 0.592 +/-0.0649 0.0225 +/-0.0649 0.0469 pCi/g Cesium-134 U 0.0206 +/-0.0197 0.0149 +/-0.0197 0.0311 pCi/g Cesium-137 0.0271 +/-0.0198 0.0115 +/-0.0198 0.0242 pCi/g Cobalt-60 U 0.00608 +/-0.0124 0.0109 +/-0.0124 0.0234 pCi/g Europium-152 U -0.012 +/-0.0336 0.0303 +/-0.0336 0.0631 pCi/g Europium-154 U - 0.00336 +/-0.0442 0.0368 +/-0.0442 0.0781 pCi/g Europium-155 U 0.0694 +/-0.0419 0.0419 +/-0.0419 0.0861 pCi/g Lead-212 0.771 +/-0.046 0.0191 +/-0.046 0.0393 pCi/g Lead-214 0.623 +/-0.0595 0.0223 +/-0.0595 0.0463 pCi/g Manganese-54 U 0.0055 +/-0.0156 0.0134 +/-0.0156 0.028 pCi/g Niobium-94 U - 1.810E- +/-0.0129 0.011 +/-0.0129 0.0229 pCi/g 05 Potassium-40 13.4 +/-0.624 0.0852 +/-0.624 0.187 pCi/g Radium-226 0.592 +/-0.0649 0.0225 +/-0.0649 0.0469 pCi/g Silver-108m U -0.0103 +/-0.0116 0.00996 +/-0.0116 0.0208 pCi/g Thallium-208 0.248 +/-0.0304 0.011 +/-0.0304 0.0231 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U - 0.00202 +/-0.0133 0.0154 +/-0.0133 0.0352 pCi/g BXFI 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-012F Project: YANKO1204 Vol. Recv.: YANK001 Sample ID: 162850018 Client ID:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-017F Project: YANKO 1204 Sample ID: 162850019 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 01-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 29.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS Actinium-228 0.885 +/-0.134 0.0432 +/-0.134 0.0917 pCi/g MJH1 06/06/06 1729 529777 1 Americium-241 U -0.00501 +/-0.119 0.082 +/-0.119 0.169 pCi/g Bismuth-212 0.680 +/-0.230 0.105 +/-0.230 0.220 pCi/g Bismuth-214 0.665 +/-0.0788 0.026 +/-0.0788 0.0543 pCi/g Cesium-134 UUI 0.00 +/-0.0291 0.0175 +/-0.0291 0.0367 pCi/g Cesium-137 U 0.0234 +/-0.0159 0.0131 +/-0.0159 0.0275 pCi/g Cobalt-60 U 0.0144 +/-0.0182 0.016 +/-0.0182 0.0339 pCi/g Europium-152 U 0.0204 +/-0.0405 0.0369 +/-0.0405 0.0767 pCi/g Europium-154 U 0.0238 +/-0.053 0.0454 +/-0.053 0.0962 pCi/g Europium-155 U 0.00 +/-0.053 0.0507 +/-0.053 0.104 pCi/g Lead-212 0.952 +/-0.0553 0.0227 +/-0.0553 0.0468 pCi/g Lead-214 0.777 +/-0.0713 0.0242 +/-0.0713 0.0504 pCi/g Manganese-54 U 0.00158 +/-0.0195 0.0136 +/-0.0195 0.0288 pCi/g Niobium-94 U 0.00894 +/-0.0154 0.0133 +/-0.0154 0.0277 pCi/g Potassium-40 15.4 +/-0.723 0.109 +/-0.723 0.237 pCi/g Radium-226 0.665 +/-0.0788 0.026 +/-0.0788 0.0543 pCi/g Silver-108m U -0.00124 +/-0.0142 0.0123 +/-0.0142 0.0257 pCi/g Thallium-208 0.279 +/-0.0412 0.0127 +/-0.0412 0.0266 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strootium-90 U -0.00321 +/-0.0118 0.014 +/-0.0118 0.0318 pCi/g BXFI 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-017F Project: YANKO1204 Sample ID: 162850019 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 95 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

72

I QUALITY CONTROL DATA 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: June 9, 2006 Client: Connecticut Yankee Atomic Power Page 1 of 9 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 162850 Parmname NOM Sample Qual OC Units RPD% REC% Ran2e Anist Date Time Rad Alpha Spec Batch 533471 QC1201101118 162485017 DUP Americium-24 I U -0.0415 U -0.00249 pCi/g 177 (0% - 100%) LCWI 05/30/06 11:55 Uncert: +/-0.0591 +/-0.0219 TPU: +/-0.0591 +/-0.0219 Curium-242 U -0.00755 U 0.0283 pCi/g 346 (0% - 100%)

Uncert: +/-0.0634 +/-0.0555 TPU: +/-0.0634 +/-0.0556 Curium-243/244 U 0.00112 U 0.0131 pCi/g 168 (0%- 100%)

Uncert: +/-0.0607 +/-0.0521 TPU: +/-0.0607 +/-0.052 1 QC1201101120 LCS Americium-24 I 12.2 10.8 pCi/g 89 (75%-125%) 05/30/06 11:55 Uncert: +/-0.975 TPU: +/-1.73 Curium-242 U -0.0056 pCi/g Uncert: +/-0.047 TPU: +/-0.0471 Curium-243/244 14.9 12.4 pCi/g 83 (75%-125%)

Uncert: +/-1.04 TPU: +/-1.95 QC1201101117 MB Americium-241 U -0.00902 pCi/g 05/30/06 11:55 Uncert: +/-0.019 TPU: +/-0.019 Curium-242 U 0.0399 pCi/g Uncert: +/-0.0638 TPU: +/-0.064 Curium-243/244 U 0.0392 pCilg Uncert: +/-0.0626 TPU: +/-0.0628 QC1201101119 162485017 MS Americium-241 12.7 U -0.0415 12.5 pCi/g 98 (75%-125%) 05/30/06 11:55 Uncert: +/-0.0591 +/-1.06 TPU: +/-0.0591 +/- 1.96 Curium-242 U -0.00755 U 0.00 pCi/g Uncert: +/-0.0634 +/-0.0517 TPU: +/-0.0634 +/-0.0517 Curium-243/244 15.5 U 0.00112 12.6 pCi/g 81 (75%-125%)

Uncert: +/-0.0607 +/-1.06 TPU: +/-0.0607 +/-1.98 Batch 533472 QC1201101122 162485017 DUP Plutonium-238 U 0.0261 U 0.00 pCi/g (0%- 100%) .CWI 05/30/06 21:29 74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 533472 Uncert: +/-0.0511 +/-0.0498 TPU: +/-0.0512 +/-0.0498 Plutonium-239/240 u 0.0459 U -0.00609 pCi/g 261 (0%- 100%)

Uncert: +/-0.0733 +/-0.0511 TPU: +/-0.0734 +/-0.0512 QC1201101124 LCS Plutonium-238 0.216 pCi/g (75%-125%) 05/30/06 21:29 Uncert: +/-0.181 TPU: +/-0.182 Plutonium-239/240 11.3 10.3 pCi/g 91 (75%-125%)

Uncert: +/-1.21 TPU: +/-1.76 QC1201101121 MB Plutonium-238 U -0.00623 pCi/g 05/31/06 07:44 Uncert: +/-0.0692 TPU: +/-0.0693 Plutonium-239/240 U -0.0274 pCi/g Uncert: +/-0.100 TPU: +/-0.100 QC1201101123 162485017 MS Plutonium-238 U 0.0261 U 0.0634 pCi/g (75%-125%) 05/30/06 21:29 Uncert: +/-0.0511 +/-0.0787 TPU: +/-0.0512 +/-0.079 Plutonium-239/240 11.7 U 0.0459 10.7 pCi/g 92 (75%-125%)

Uncert: +/-0.0733 +/-0.971 TPU: +/-0.0734 +/-1.52 Batch 533473 QC1201101126 162485017 DUP Plutonium-241 U -8.66 U -6.36 pCi/g 0 (0% - 100%) .CW I 06/03/06 07:35 Uncert: +/-8.72 +/-6.79 TPU: +/-8.77 +/-6.82 QC1201101128 LCS Plutonium-241 131 106 pCi/g 81 (75%-125%) 06/03/06 08:07 Uncert: +/-12.3 TPU: +/-16.4 QC1201101125 MB Plutonium-241 U -1.18 pCi/g 06/03/06 07:18 Uncert: +/-9.02 TPU: +/-9.02 QC1201101127 162485017 MS Plutonium-241 135 U -8.66 146 pCi/g 108 (75%-125%) 06/03/06 07:51 Uncert: +/-8.72 +/-14.7 TPU: +/-8.77 +/-20.1 Rad Gamma Spec Batch 529777 QC1201092336 162850001 DUP Actinium-228 0.908 0.991 pCi/g 9 (0% - 100%) MJHI 06/06/06 17:30 Uncert: +/-0.297 +/-0.200

+/-0.200 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 3 of 9 Parmname NOM Samnle Oual OC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 529777 TPU: +/-0.297 Americium-241 u -0.0354 U -0.0552 pCi/g 44 (0%-100%)

Uncert: +/-0.0542 +/-0.0664 TPU: +/-0.0542 +/-0.0664 Bismuth-212 U 0.292 0.971 pCi/g 108* (0%-100%)

Uncert: +/-0.518 +/-0.279 TPU: +/-0.518 +/-0.279 Bismoth-214 0.606 UUI 0.00 pCi/g 37* (0%- 100%)

Uncert: +/-0.164 +/-0.0897 TPU: +/-0.164 +/-0.0897 Cesium- 134 U 0.0697 UUI 0.00 pCi/g 25 (0% - 100%)

Uncert: +/-0.0502 +/-0.0372 TPU: +/-0.0502 +/-0.0372 Cesium- 137 U 0.00312 U 0.00796 pCi/g 87 (0%- 100%)

Uncert: +/-0.0432 +/-0.0195 TPU: +/-0.0432 +/-0.0195 Cobalt-60 U 0.047 U 0.00696 pCi/g 148 (0%- 100%)

Uncert: +/-0.0461 +/-0.0198 TPU: +/-0.0461 +/-0.0198 Europium- 152 U 0.0184 U -0.0069 pCi/g 440 (0%- 100%)

Uncert: +/-0.100 +/-0.0474 TPU: +/-0.100 +/-0.0474 Europium- 154 U -0.039 U -0.0214 pCi/g 59 (0% - 100%)

Uncert: +/-0.132 +/-0.0542 TPU: +/-0.132 +/-0.0542 Europium- 155 U 0.0871 U 0.00 pCi/g 27 (0%- 100%)

Uncert: +/-0.0891 +/-0.0568 TPU: +/-0.0891 +/-0.0568 Lead-212 0.878 0.940 pCi/g 7 (0% - 20%)

Uncert: +/-0.106 +/-0.0945 TPU: +/-0.106 +/-0.0945 Lead-214 0.438 0.476 pCi/g 8 (0%- 100%)

Uncert: +/-0.111 +/-0.0881 TPU: +/-0.111 +/-0.0881 Manganese-54 U 0.029 U 0.0167 pCi/g 54 (0%- 100%)

Uncert: +/-0.0728 +/-0.0198 TPU: +/-0.0728 +/-0.0198 Niobium-94 U -0.000518 U 0.000452 pCi/g 2970 (0%- 100%)

Uncert: +/-0.0403 +/-0.0174 TPU: +/-0.0403 +/-0.0174 Potassium-40 16.0 15.9 pCi/g I (0% - 20%)

Uncert: +/-1.34 +/-1.25 TPU: +/-1.34 +/-1.25 Radium-226 0.606 0.416 pCi/g 37 (0%- 100%)

Uncert: +/-0.164 +/-0.0897 TPU: +/-0.164 +/-0.0897 Silver- 108m U -0.0164 U -0.0141 pCi/g 15 (0%- 100%)

Uncert: +/-0.0372 +/-0.0155 76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 4 of 9 Parmname NOM Sample Qual OC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 529777 TPU: +/-0.0372 +/-0.0155 Thallium-208 0.422 0.278 pCi/g 41*

Uncert: +/-0.0918 +/-0.0482 TPU: +/-0.0918 +/-0.0482 LCS Actinium-228 U 0.194 pCi/g 06/05/06 18:10 Uncert: +/-0.588 TPU: +/-0.588 Americium-24 I 23.4 21.6 pCi/g 92 (75%-125%)

Uncert: +/-1.42 TPU: +/-1.42 Bismuth-212 U -0.294 pCi/g Uncert: +/-1.10 TPU: +/-1.10 Bismuth-214 U -0.0783 pCi/g Uncert: +/-0.242 TPU: +/-0.242 Cesium- 134 U 0.0415 pCi/g Uncert: +/-0.146 TPU: +/-0.146 Cesium-137 9.64 9.61 pCi/g 100 (75%-125%)

Uncert: +/-0.473 TPU: +/-0.473 Cobalt-60 15.1 15.5 pCi/g 103 (75%-125%)

Uncert: +/-0.684 TPU: +/-0.684 Europium- 152 U 0.587 pCi/g Uncert: +/-0.340 TPU: +/-0.340 Europium- 154 U -0.109 pCi/g Uncert: +/-0.334 TPU: +/-0.334 Europium- 155 U 0.422 pCi/g Uncert: +/-0.417 TPU: +/-0.417 Lead-212 U -0.0619 pCi/g Uncert: +/-0.187 TPU: +/-0.187 Lead-214 U 0.114 pCi/g Uncert: +/-0.234 TPU: +/-0.234 Mangatnese-54 U 0.0408 pCi/g Uncert: +/-0.146 TPU: +/-0.146 Niobiurn-94 U 0.197 pCi/g Uncert: +/-0.208 TPU: +/-0.208 Potassitim-40 U 0.364 pCi/g 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 5 of 9 Pnrmna.mP NAM S-mnle O.al OC Units RPD% REC%

NOM I Ranee Anist Date Time Parmname Rad Gamma Spec Batch 529777 Uncert: +/-1.23 TPU: +/-1.23 Radium-226 U -0.0783 pCi/g (75%-125%)

Uncert: +/-0.242 TPU: +/-0.242 Silver- 108m U 0.00944 pCi/g Uncert: +/-0.139 TPU: +/-0.139 Thallium-208 U 0.0562 pCi/g Uncert: +/-0.135 TPU: +/-0.135 QC1201092335 MB Actinium-228 U 0.122 pCi/g 06/06/06 17:29 Uncert: +/-0.141 TPU: +/-0.141 Americium-241 U 0.0315 pCi/g Uncert: +/-0.0307 TPU: +/-0.0307 Bismuth-212 U 0.0765 pCi/g Uncert: +/-0.193 TPU: +/-0.193 Bismuth-214 U 0.0567 pCi/g Uncert: +/-0.0537 TPU: +/-0.0537 Cesium- 134 U 0.022 pCi/g Uncert: +/-0.0291 TPU: +/-0.0291 Cesium- 137 U -0.00274 pCi/g Uncert: +/-0.0276 TPU: +/-0.0276 Cobalt-60 U 0.0134 pCi/g Uncert: +/-0.0252 TPU: +/-0.0252 Europium- 152 U 0.0132 pCi/g Uncert: +/-0.0615 TPU: +/-0.0615 Europium- 154 U 0.0414 pCi/g Uncert: +/-0.0762 TPU: +/-0.0762 Europium- 155 U 0.0411 pCi/g Uncert: +/-0.0525 TPU: +/-0.0525 Lead-212 U 0.051 pCi/g Uncert: +/-0.0368 TPU: +/-0.0368 Lead-214 U 0.0556 pCi/g Uncert: +/-0.0473 TPU: +/-0.0473 78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 529777 Manganese-54 U 0.00722 pCi/g Uncert: +/-0.0283 TPU: +/-0.0283 Niobium-94 U 0.0168 pCi/g Uncert: +/-0.0246 TPU: +/-0.0246 Potassium-40 U 0.159 pCi/g Uncert: +/-0.284 TPU: +/-0.284 Radium-226 U 0.0567 pCi/g Uncert: +/-0.0537 TPU: +/-0.0537 Silver-108m U 0.00464 pCi/g Uncert: +/-0.0224 TPU: +/-0.0224 Thallium-208 U 0.0292 pCi/g Uncert: +/-0.0271 TPU: +/-0.0271 Rad Gas Flow Batch 534447 QC1201103431 162850003 DUP Strontium-90 U -0.00381 U 0.00938 pCi/g 0 (0% - 100%) BXFI 06/03/06 14:46 Uncert: +/-0.00625 +/-0.0172 TPU: +/-0.00626 +/-0.0172 QC1201103433 LCS Strontium-90 1.09 0.819 pCi/g 76 (75%-125%) 06/05/06 21:17 Uncert: +/-0.0656 TPU: +/-0.070 QC1201103430 MB Strontium-90 U 0.00139 pCi/g 06/03/06 14:46 Uncert: +/-0.0121 TPU: .+/-0.0121 QC1201103432 162850003 MS Strontium-90 1.43 U -0.00381 1.34 pCi/g 93 (75%-125%) 06/03/06 14:46 Uncert: +/-0.00625 +/-0.0899 TPU: +/-0.00626 +/-0.0952 Rad Liquid Scintillation Batch 531618 QC1201096632 163173001 DUP Iron-55 U 10.3 U 5.38 pCi/g 0 (0% - 100%) SLNI 05/31/06 12:49 Uncert: +/-20.1 +/-18.0 TPU: +/-20.1 +/-18.1 QC1201096634 LCS Iron-55 437 428 pCi/g 98 (75%-125%) 05/31/06 13:22 Uncert: +/-40.6 TPU: +/-62.3 QC1201096631 MB Iron-55 U 3.58 pCi/g 05/31/06 12:32 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 531618 Uncert: +/-24.7 TPU: +/-24.7 QC1201096633 163173001 MS Iron-55 569 U 10.3 544 pCi/g 96 (75%-125%) 05/31/06 13:05 Uncert: +/-20.1 +/-39.3 TPU: +/-20.1 +/-69.3 Batch 531622 QC1201096645 163173001 DUP Nickel-63 U -6.64 U -5.49 pCi/g (0% - 100%) SLNI 05/28/06 01:38 Uncerl: +/-7.30 +/-4.33 TPU: +/-7.31 +/-4.33 QC1201096647 LCS Nickel-63 362 301 pCi/g 83 (75%-125%) 05/28/06 03:40 Uncert: +/-7.49 TPU: +/-11.1 QC1201096644 MB Nickel-63 U -1.66 pCi/g 05/28/06 00:37 Uncert: +/-3.41 TPU: +/-3.41 QC1201096646 163173001 MS Nickel-63 460 U -6.64 395 pCi/g 86 (75%-125%) 05/28/06 02:39 Uncert: +/-7.30 +/-9.22 TPU: +/-7.31 +/-14.9 Batch 531704 QC1201096868 162583001 DUP Technetium-99 U 0.161 U 0.239 pCi/g 0 (0% - 100%) SXEI 05/31/06 00:27 Uncert: +/-0.254 +/-0.273 TPU: +/-0.255 +/-0.273 QC1201096870 LCS Technetium-99 12.5 11.1 pCi/g 89 (75%-125%) 05/31/06 01:00 Uncert: +/-0.474 TPU: +/-0.545 QC1201096867 MB Technetium-99 U 0.163 pCi/g 05/31/06 00:11 Uncert: +/-0.214 TPU: +/-0.214 QC1201096869 162583001 MS Technetium-99 13.1 U 0.161 11.6 pCi/g 89 (75%-125%) 05/31/06 00:44 Uncert: +/-0.254 +/-0.583 TPU: +/-0.255 +/-0.649 Batch 531705 QC1201096878 162583001 DUP Tritium U 1.17 U 6.01 pCi/g 0 (0% - 100%) NXP I 05/28/06 09:10 Uncert: +/-4.09 +/-4.70 TPU: +/-4.09 +/-4.70 QC1201096880 LCS Tritium 41.4 44.8 pCi/g 108 (75%-125%) 05/28/06 10:14 Uncert: +/-5.68 TPU: +/-5.73 80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 8 of 9 Parmname NOM Saniiple Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 531705 QC0201096877 MB Tritium U 0.0641 pCi/g 06/03/06 05:11 Uncert: +/-0.533 TPU: +/-0.533 QC1201096879 162583001 MS Tritium 45.7 U 1.17 52.3 pCi/g 114 (75%-125%) 05/28/06 09:42 Uncert: +/-4.09 +/-6.44 TPU: +/-4.09 +/-6.50 Batch 534984 QC1201104746 163173001 DUP Carbon- 14 U 0.00714 U 0.00246 pCi/g 0 (0%- 100%) ATH2 06/05/06 03:00 Uncert: +/-0.0996 +/-0.103 TPU: +/-0.0996 +/-0.103 QCI201104748 LCS Carbon- 14 12.1 11.3 pCi/g 94 (75%-125%) 06/05/06 05:20 Uncert: +/-0.855 TPU: +/-0.873 QC1201104745 MB Carbon- 14 U -0.0368 pCi/g 06/05/06 00:57 Uncert: +/-0.101 TPU: +/-0.101 QC1201104747 163173001 MS Carbon- 14 12.9 U 0.00714 12.1 pCi/g 94 (75%-125%) 06/05/06 05:02 Uncert: +/-0.0996 +/-0.917 TPU: +/-0.0996 +/-0.936 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded 81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 162850 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time h

N/A indicates that spike recovery limits do not apply when sample concentration eceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a. control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

82

Table of Contents General Narrative ................................................................... 1 Chain of Custody And Supporting Dpcumentation ........... 5 Radiological Analysis ........................................................... 12 Sample Data Summary ....................................................... 18 Q uality C ontrol D ata ............................................................ 60

General Narrative 1

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170256 SDG: MSR #06-1160 September 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road' Charleston, South Carolina 29407 Telephone Number:

(843) 556-8171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC (GEL) in Charleston, South Carolina on August 25, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and' signatures.

The laboratory received the following sample(s):

Sample ED Client Sample ID 170256001 9106-0006-005A 170256002 9106-0006-005B 170256003 9106-0006-005C 170256004 9106-0006-005D 170256005 9106-0005-010A 170256006 9106-0005-OIOB 170256007 9106-0005-OIOC 170256008 9106-0005-010D 170256009 9106-0014-033A GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

P.O. Box 30712 - Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax 243) 766-1178 - www.gel.com

170256010 9106-0014-033Bl 170256011 9106-0014-033C 170256012 9106-0014-033D 170256013 9106-0004-013A 170256014 9106-0004-013B 170256015 9106-0004-013C 170256016 9106-0004-013D 170256017 9106-0004-005A 170256018 9106-0004-005B 170256019 9106-0004-005C 170256020 9106-0004-005D Items of Note:

There are no items of note.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engieering Laboratories (GEL) Standard Operating Procedures. Any technical or administraive problems during analysis, data review, and reduction are listed below by analytic'll parameter.

Analytical Request:

Twenty soil samples were analyzed for FSSGAM and Sr-90.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically a"d for completeness, for other than the conditions detailed above. Release of the data c6ntained in this hard copy data package has been authorized by the Laboratory Manager orla designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax J43) 766-1178 - www.gel.com

List of current GEL Certifications as of 06 September 2006 State Certification

-.- - Calfifornia 6)115 1C* ..... .

____Colorado_ ____. ... . (ent~ngtabs.. ..

- C onnecticut PH-016-9 Dept. of Navy NFESC413 4 EPA--- w--- J --

FloridaINELAP E87156 Georgia E87156 (FLNELAP)

Idaho N/A Illinois . _200029 Indiana C-SC-0I Kansas ......... E-i0332 Kentucky 90129 Maryland 270 Massachusetts M-,-SC-O12 Michigan _ 9903 Nevada SC12

__ New Jersey -SC002-New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R- 158 Oklahoma 990-4 Pennsylvania 684*.5 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A

- U.S. Dept. of Agriculture S-52597 US Army Corps Utah of Engineer N/A 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 4

Chain of Custody And Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00511 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407

  • 843 556 8171. Attn. Cheryl Jones (A c o Priority: [] 30 D. 0 14 D. [] 7 D.

Sample Container Size-r"-c 5' 'f Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0006-005A 8/8/06 14:35 SE C BP X X Transferred from COC # 2006-00488 9106-0006-005B 8/8/06 15:08 SE C BP X X Transferred from COC # 2006-00488 9106-0006-005C 8/9/06 07:46 SE C BP X X Transferred from COC # 2006-00307 9106-0006-005D 8/9/06 08:18 SE C BP X x Transferred from COC # 2006-00307 NOTES: PO#: 002332 MSR#: 06-1160 SSWP#NA SLTP QA E] Radwaste QA Ej Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: _ Deg. C E]ups WiHand Custody Sealed?

Y0- NEI

1) Relinquished By Date/Time 2) Rec ved By Date/Time Custody Seal Intact?

LI Other

3) Relinquished By Date/Time 4) Pceived By-(, ,Date/Time YC NEI Bill of Lading #

"V00a 4 611.? 6'4,-1

K,.

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00512 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories )

2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C, (A Container Priority: ] 30 D. Z 14 D. ] 7 D.

Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0005-01 OA 8/9/06 09:03 SE C BP X X Transferred from COC # 2006-00489 9106-0005-010B 8/9/06 09:33 SE C BP X X Transferred from COC # 2006-00489 9106-0005-01OC 8/9/06 10:04 SE C BP X X Transferred from COC # 2006-00489 9106-0005-01OD 8/9/06 10:56 SE C BP X X Transferred from COC # 2006-00489 NOTES: PO #: 002332 MSR#: 06- 110 SSWP# NA Z LTP QA [I Radwaste QA 0 Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: __ Deg. C El uPs El Hand Custody Sealed?

YE? NO

1) Relinquished By 4 9_-.4.-ol Dat /Time

//34_0 2 ceive~dBy De/Time Custody Seal Intact?

J h-tC'- ý C4'r [ Other

3) Relinquished By 1ate/Time 49eceived By -Dat=Time Mt YO NO Bill of Lading#

q 00 4631 64

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00513 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones CA

  • Priority: [] 30 D. N 14 D. ] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0014-033A 8/11/06 07:58 SE C BP X X Transferred from COC # 2006-00493 C9106-0014-033B 8/11/06 08:24 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033C 8/11/06 08:45 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033D 8/11/06 09:16 SE C BP X X Transferred from COC 4 2006-00493 NOTES: PO #: 002332 MSR #: 06-1160 SSWP# NA E LTP QA E1 Radwaste QA E] Non QA Samples Shipped Via:

[ Fed Ex Internal Container Temp.: _ Deg. C auPs l Hand _Custody Sealed? -

YO NO]

Custody Seal Intact?

3 Relinquished By Da e/Time 2) ived By Date/Time E] Other

3) Relinquished By Date/Time 4) R~vived By D-1'ate/Time YO NO]

Bill of Lading #

T9wQ 404 1q 6444q

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00520 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn ýn Priority: [] 30 D. g 14 D. Z 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0004-013A 8/9/06 12:53 SE C BP X X Transferred from COC 2006-00490 9106-0004-013B 8/9/06 13:27 SE C BP X X Transferred from COC 2006-00490

'9106-0004-013C 8/9/06 13:57 SE C BP X X Transferred from COC 2006-00490 9106-0004-013D 8/9/06 14:28 SE C BP X X Transferred from COC 2006-00490 9106-0004-OOSA 8/9/06 14:58 SE C BP X X Transferred from COC 2006-00490 9106-0004-005B 8/10/06 07:41 SE C BP X X Transferred from COC 2006-00491 9106-0004-005C 8/10/06 08:09 SE C BP X X Transferred from COC 2006-00491 9106-0004-005D 8/10/06 08:49 SE C BP X X Transferred from COC 2006-00491 0

NOTES: PO #: 002332 MSR#4: 06-116 SSWP#NA 2 LTP QA El Radwaste QA [: Non QA Samples Shipped Via: Internal Container Temp.:_ Deg. C Z Fed Ex El UPS LI Hand Custody Sealed?

YEO ND

1) Relinquished By Date/rime 2) Re ived By - Date/Time Custody Seal Intact?

J rto, A rz-g-r Y4-os //70 ,, F1 Other

3) Relinquished By Date/Time 4 ceived By Date/Time YEI NO Bill of Lading #

7yoo 4 6'44'

Connecticut Yankee Staicment of Work for Analytical Lab Services -.CYis-Iso-Sool0

  • " .Figure 1. Samle Chec.-in List Dateffi~me R eVed__________________________

SDc3#:

Work Order Number ___"

Shipping Cdatainer IMAM Lf3L4YA ChainofCustqdy8.A# -W3 00.

  • 1. Custdy Seas.ofishppiigcontainer intact?... Yes ;41o
2. Custody Seals dated and signed? Yes E1Ko I."
3. Chain-of-Custody eord pr.sent?" Yes.,r I.]

.4- Cooler iemperature Z

5. Vermiculite/packing materials is: Wet H]ry.]
  • 1 . Numberofsamples*W shipping o nta irj:j "
7. Sample holding times etxedd? . Yes [,go

.8. Samples have.. I

.-.... hazard labcls

-e.

.. .appropriate sample labels.

... irŽCiitodyseals I

9. Samnples amc:

.

  • gooil condition .. eCakdg

-broken Jav

-- air bubbles Wer ay a,-aie ideti, in l ,aceit? ,

JO. Yes[JNo(<

II. S.De=tiption ofanomalies(include ampIe numbers):

""______________"_____"______________I.

I; 1:

~1 10

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO1 Figure 1. Sample Check-in List.

c~i~

Reclve&:~ ~ 7 4-Work Order Nutaber: ___________________

Shipping Cdntainer I :13 Ot T k'Lý- .Chain of Custody # 2Z440 6 - R-

_72.-

1. Custody Seals. on shipping container intact?.. -Yes ['olý
2. Custody Seals dated and signed? Yes" *- (,1
3. Chain-of-Custody record present? Yes kr,1.N"O
4. Cooler temperature . _ 2 ',
5. Vermiculite/packing materials is: Wet V ,a 6.: Number of samples in shipping container:
7. Sample hokling times exceeded? Yes 4,- Io I
8. Samples have:

-.__hazard labels

.__e6ustody seals -appropriate sample labels

9. Samples are:

_ in goqd condition ea'ng

._,,Zbroke - have air bubbles

10. Were any anomalies identified irtsample receipt? Yes [ 'Noo J
11. Description of anornalies (include sample mbers): 'D..* -9/t, -t /,f.' k sanpl nmb (includekfr 11

RADIOLOGICAL ANALYSIS 12

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 170256 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 563436 Prep Batch Number: 562444 Sample ID Client ID 170256001 9106-0006-005A 170256002 9106-0006-005B 170256003 9106-0006-005C 170256004 9106-0006-005D 170256005 9106-0005-01OA 170256006 9106-0005-OIOB 170256007 9106-0005-OIOC 170256008 9106-0005-OIOD 170256009 9106-0014-033A 170256010 9106-0014-033B 170256011 9106-0014-033C 170256012 9106-0014-033D 170256013 9106-0004-013A 170256014 9106-0004-013B 170256015 9106-0004-013C 170256016 9106-0004-013D 170256017 9106-0004-005A 170256018 9106-0004-005B 170256019 9106-0004-005C 170256020 9106-0004-005D 1201171525 Method Blank (MB) 1201171526 170256001(9106-0006-005A) Sample Duplicate (DUP) 1201171527 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 13

narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 170256001 (9106-0006-005A).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 170256007 (9106-0005-010C), 170256016 (9106-0004-013D) and 170256019 (9106-0004-005C) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information 14

Qualifier Reason Analyte Sample U' Data rejected due to high counting uncertainty Bismuth-212 170256009 UI Data rejected due to interference. Europium- 155 170256003 170256009 170256019 170256020 UI Data rejected due to low abundance. Bismuth-214 170256008 Cesium- 134 170256005 170256007 170256008 170256012 170256013 170256019 1201171526 Europium- 155 170256018 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 562563 Prep Batch Number: 562478 Dry Soil Prep GL-RAD-A-021 Batch Number: 562444 15

Sample ID Client ID 170256001 9106-0006-005A 170256002 9106-0006-005B 170256003 9106-0006-005C 170256004 9106-0006-005D 170256005 9106-0005-01OA 170256006 9106-0005-OIOB 170256007 9106-0005-01OC 170256008 9106-0005-OIOD 170256009 9106-0014-033A 170256010 9106-0014-033B 170256011 9106-0014-033C 170256012 9106-0014-033D 170256013 9106-0004-013A 170256014 9106-0004-013B 170256015 9106-0004-013C 170256016 9106-0004-013D 170256017 9106-0004-005A 170256018 9106-0004-005B 170256019 9106-0004-005C 170256020 9106-0004-005D 1201169421 Method Blank (MB) 1201169422 170256002(9106-0006-005B) Sample Duplicate (DUP) 1201169423 170256002(9106-0006-005B) Matrix Spike (MS) 1201169424 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Guality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 170256002 (9106-0006-005B).

16

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

17

SAMPLE DATA

SUMMARY

18

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1160 GEL Work Order: 170256 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 19

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005A Project: YANK01204 Sample ID: 170256001 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 08-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 15.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.966 +/-0.192 0.0743 +/-0.192 0.149 pCi/g MJHI 09/01/06 1057 563436 1 Americium-241 U 0.0375 +/-0.0387 0.0329 +/-0.0387 0.0658 pCi/g Bismuth-212 0.366 +/-0.306 0.175 +/-0.306 0.350 pCi/g Bismuth-214 0.650 +/-0.135 0.042 +/-0.135 0.0839 pCi/g Cesium-134 U 0.0366 +/-0.0355 0.0288 +1-0.0355 0.0576 pCi/g Cesium-137 0.0666 +/-0.0355 0.0236 +1-0.0355 0.0472 pCi/g Cobalt-60 0'104 +/-0.0726 0.0286 +/-0.0726 0.0573 pCi/g Europium-152 U 0.00636 +/-0.0728 0.0538 +/-0.0728 0.108 pCi/g Europium-154 U -0.0788 +/-0.0938 0.0718 +/-0.0938 0.143 pCi/g Europium-155 U 0.0672 +/-0.0554 0.0518 +1-0.0554 0.104 pCi/g Lead-212 0.871 +/-0.0971 0.0305 +/-0.0971 0.061 pCi/g Lead-214 0.727 +/-0.105 0.0379 +/-0.105 0.0757 pCi/g Manganese-54 U -0.00916 +/-0.0319 0.0232 +/-0.0319 0.0465 pCi/g Niobium-94 U 0.0101 +/-0.0244 0.0223 +/-0.0244 0.0445 pCi/g Potassium-40 11.3 +/-0.986 0.201 +/-0.986 0.403 pCi/g Radium-226 0.650 +/-0.135 0.042 +/-0.135 0.0839 pCi/g Silver-108m U -0.0067 +/-0.0208 0.018 +/-0.0208 0.036 pCi/g Thallium-208 0.283 +/-0.0618 0.0212 +/-0.0618 0.0423 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.0254 +/-0.0193 0.0126 +/-0.0193 0.0298 pCi/g KSDI 09/07/06 1742 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 20

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005A Proiect: YANK01204 Sample ID: 170256001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

21

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Ci~rtflgMirtp af Anqlvkic Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005B Proiect: YANKO 1204 Sample ID: 170256002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 08-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 14.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actiniumn-228 0.606 +/-0.152 0.0599 +/-0.152 0.131 pCi/g MJHI 09/01/06 1220 563436 1 Americium-241 U 0.101 +/-0.114 0.0861 +/-0.114 0.179 pCi/g Bismuth-212 0.685 +/-0.232 0.134 +/-0.232 0.290 pCi/g Bismuth-214 0.435 +/-0.0852 0.0332 +/-0.0852 0.0708 pCi/g Cesium-134 U 0.0313 +/-0.0286 0.0238 +/-0.0286 0.0507 pCi/g Cesium-137 0.114 +/-0.0348 0.0206 +/-0.0348 0.0438 pCi/g Cobalt-60 0.436 +/-0.0586 0.0151 +/-0.0586 0.0345 pCi/g Europium-152 U -0.0448 +/-0.0525 0.0416 +1-0.0525 0.0882 pCi/g Europium- 154 U -0.0186 +/-0.0685 0.0562 +/-0.0685 0.124 pCi/g Europium- 155 U 0.0423 +/-0.0579 0.0552 +/-0.0579 0.114 pCi/g Lead-212 0.643 +/-0.0623 0.0268 +/-0.0623 0.056 pCi/g Lead-214 0.462 +/-0.0885 0.033 +/-0.0885 0.0696 pCi/g Manganese-54 U -0.0167 +/-0.0261 0.0174 +/-0.0261 0.0377 pCi/g Niobium-94 U 0.00909 +/-0.0195 0.0173 +/-0.0195 0.0369 pci/g Potassium-40 11.1 +/-0.983 0.179 +/-0.983 0.399 pCi/g Radium-226 0.435 +/-0.0852 0.0332 +/-0.0852 0.0708 pCi/g Silver-108m U - 0.00194 +/-0.0168 0.0149 +/-0.0168 0.0317 pCi/g Thallium-208 0.243 +/-0.0457 0.0176 +/-0.0457 0.0377 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid ALL FSS Strontium-90 U 0.00501 +/-0.0149 0.0117 +/-0.0149 0.0278 pCi/g KSDI 09/07/06 1742 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil.Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 22

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005B Project: YANK01204 Sample ID: 170256002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

23

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005C Project: YANKO 1204 Sample ID: 170256003 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 31.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.284 0.101 +/-0.284 0.215 pCi/g MJHl 09/01/06 1221 563436 1 Americium-241 U 0.0251 +/-0.0367 0.0332 +/-0.0367 0.0683 pCi/g Bismuth-212 0.684 +/-0.424 0.178 +/-0.424 0.383 pCi/g Bismuth-214 0.673 +/-0.121 0.0445 +/-0.121 0.0947 pCi/g Cesium-134 U 0.0516 F/-0.0548 0.0344 +/-0.0548 0.0729 pCi/g Cesium-137 0.317 +/-0.0544 0.0247 +/-0.0544 0.0528 pCi/g Cobalt-60 0.821 +/-0.0911 0.0294 +/-0.0911 0.064 pCi/g Europium-152 U -0.049 F/-0.0652 0.0539 +/-0.0652 .0.114 pCi/g Europium-154 U 0.0883 F/-0.0913 0.0839 +/-0.0913 0.182 pCi/g Europium-155 UI 0.00 +/-0.0926 0.0506 +/-0.0926 0.105 pCi/g Lead-212 1.01 /-0.0819 0.0329 +/-0.0819 0.0685 pCi/g Lead-214 0.828 +/-0.117 0.0423 +/-0.117 0.089 pCi/g Manganese-54 U -0.0228 F/-0.0296 0.0238 +/-0.0296 0.0513 pCi/g Niobium-94 U -0.0353 +/-0.0279 0.0205 +/-0.0279 0.044 pCi/g Potassium-40 12.4 +1-1.15 0.189 +/-1.15 0.431 pCi/g Radium-226 0.673 +/-0.121 0.0445 +/-0.121 0.0947 pCi/g Silver-108m U 0.00475 -*/-0.0263 0.0227 +/-0.0263 0.0477 pCi/g Thallium-208 0.382 F/-0.0567 0.0242 +/-0.0567 0.0515 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00738 /-0.0142 0.0107 +/-0.0142 0.0255 pCi/g KSDI 09/07/06 1745 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2. 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 24

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005C Project: YANKO 1204 Sample ID: 170256003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 104 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

25

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005D Proiect: YANK01204 Sample ID: 170256004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 28.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.197 0.0659 +/-0.197 0.143 pCi/g MJHI 09/01/06 1221 563436 1 Americium-241 U 0.0605 +/-0.132 0.088 +/-0.132 0.182 pCi/g Bismuth-212 0.534 +/-0.328 0.168 +/-0.328 0.358 pCi/g Bismuth-214 0.594 +1-0.105 0.0384 +1-0.105 0.0813 pCi/g Cesium-134 U 0.0478 +/-0.046 0.0253 +/-0.046 0.0537 pCi/g Cesium- 137 0.103 +/-0.0401 0.0181 +/-0.0401 0.0389 pCi/g Cobalt-60 0.148 +/-0.0644 0.0204 +/-0.0644 0.045 pCi/g Europium-152 U 0.00143 +/-0.0589 0.0517 +/-0.0589 0.109 pCi/g Europium-154 U 0.0154 +/-0.0766 0.0653 +/-0.0766 0.142 pCi/g Europium-155 U 0.0625 +/-0.0643 0.0586 +/-0.0643 0.121 pCi/g Lead-212 0.900 +/-0.0831 0.0345 +/-0.0831 0.0714 pCi/g Lead-214 0.854 +/-0.106 0.0372 +/-0.106 0.078 pCi/g Manganese-54 U -0.013 +/-0.0244 0.0203 +/-0.0244 0.0434 pCi/g Niobium-94 U 0.0144 +/-0.022 0.0192 +/-0.022 0.0408 pCi/g Potassium-40 11.6 +/-0.886 0.177 +/-0.886 0.396 pCi/g Radium-226 0.594 +1-0.105 0.0384 +/-0.105 0.0813 pCi/g Silver-108m U 0.0118 +/-0.0187 0.0169 +/-0.0187 0.0357 pCi/g Thallium-208 0.310 +/-0.0591 0.0199 +/-0.0591 0.0422 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0 .000446 +/-0.0198 0.0166 +/-0.0198 0.0376 pCi/g KSD1 09/07/06 1740 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 26

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005D Proiect: YANK01204 Sample ID: 170256004 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 50 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

27

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010A Project: YANKO 1204 Sample ID: 170256005 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 60.7%

Parameter Qualifier Result Ur ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.22 +/-0.394 0.120 +/-0.394 0.255 pCi/g MJH1 09/01/06 1221 563436 1 U 0.0503 -- 0.0522 0.0424 +/-0.0522 0.0872 pCi/g Americium-241 -+

Bismuth-212 0.628 +/-0.547 0.277 +/-0.547 0.584 pCi/g Bismuth-214 0.834 +/-0.160 0.0633 +/-0.160 0.133 pCi/g Cesium-134 UI 0.00 + /-0.0832 0.0429 +/-0.0832 0.0903 pCi/g U 0.0463 -/-0.0542 0.0333 +/-0.0542 0.0703 pCi/g Cesium-137 4 U 0.077 -/-0.0516 0.0472 +/-0.0516 0.100 pCi/g Cobalt-60 4 U 0.00822 -/-0.0958 0.0766 +/-0.0958 0.160 pCi/g Europium-152 4 Europium- 154 U-0.000512 +/-0.129 0.0917 +/-0.129 0.199 pCi/g Europium-155 U 0.0659 +/-0.115 0.0674 +/-0.115 0.139 pCi/g Lead-212 0.933 +/-0.111 0.0593 +/-0.111 0.122 pCi/g Lead-214 0.787 +/-0.146 0.0602 +/-0.146 0.125 pCi/g Manganese-54 U -0.0199 4 1-0.0442 0.0342 +/-0.0442 0.0725 pCi/g Niobium-94 U -0.0359 +-/-0.0364 0.0275 +/-0.0364 0.0583 pCi/g Potassium-40 20.0 +1-1.50 0.288 +/-1.50 0.634 pCi/g Radium-226 0.834 +/-0.160 0.0633 +/-0.160 0.133 pCi/g Silver-108m U -0.00415 +/-0.0338 0.0282 +/-0.0338 0.0591 pCi/g Thallium-208 0.347 +/-0.0918 0.0332 +/-0.0918 0.0698 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00442 +*/-0.0146 0.0116 +/-0.0146 0.0274 pCi/g KSD1 09/07/06 1745 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 28

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOA Project: YANK01204 Sample ID: 170256005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

29

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOB Proiect: YANK01204 Sample ID: 170256006 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 61.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.10 +/-0.245 0.0778 +/-0.245 0.168 pCi/g MJHI 09/01/06 1221 563436 1 Americium-241 U -0.00576 +/-0.0366 0.0263 +/-0.0366 0.0543 pCi/g Bismuth-212 0.760 +/-0.351 0.189 +/-0.351 0.402 pCi/g Bismuth-214 0.576 +/-0.139 0.0442 +/-0.139 0.0936 pCi/g Cesium-134 U 0.0332 +/-0.0438 0.0314 +/-0.0438 0.0665 pCi/g Cesium-137 0.0908 +/-0.0468 0.0231 +/-0.0468 0.0493 pCi/g Cobalt-60 0.115 +/-0.0522 0.0225 +/-0.0522 0.0499 pCi/g Europium-152 U 0.00833 +/-0.068 0.0546 +/-0.068 0.115 pCi/g Europium- 154 U -0.0828 +/-0.106 0.0808 +/-0.106 0.175 pCi/g Europium-155 U 0.0871 +/-0.0591 0.0504 +/-0.0591 0.104 pCi/g Lead-212 1.08 +/-0.0778 0.0306 +/-0.0778 0.0636 pCi/g Lead-214 0.812 +/-0.0928 0.0385 +/-0.0928 0.081 pCi/g Manganese-54 U 0.0145 +/-0.0313 0.0262 +/-0.0313 0.0557 pCi/g Niobium-94 U 0.00876 +/-0.0271 0.0226 +/-0.0271 0.0479 pCi/g Potassium-40 19.3 +/-1.35 0.236 +/-1.35 0.521 pCi/g Radium-226 0.576 +/-0.139 0.0442 +/-0.139 0.0936 pCi/g Silver-108m U -0.00887 +/-0.0232 0.0191 +/-0.0232 0.0403 pCi/g Thallium-208 0.282 +/-0.0641 0.0224 +/-0.0641 0.0475 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.00561 +/-0.0185 0.0162 +/-0.0185 0.0368 pCi/g KSDI 09/07/06 1746 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 30

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010B Project: YANK01204 Sample ID: 170256006 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 89 (25/-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: '362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010C Proiect: YANK01204 Sample ID: 170256007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 49.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 +/-0.196 0.0698 +/-0.196 0.148 pCi/g MJH1 09/05/06 2124 563436 1 Americium-241 U 0.00111 +/-0.108 0.0862 +/-0.108 0.177 pCi/g Bismuth-212 0.539 +/-0.392 0.142 +/-0.392 0.300 pCi/g Bismuth-214 0.626 +/-0.101 0.0371 +/-0.101 0.0775 pCi/g Cesium-134 UI 0.00 +/-0.0318 0.025 +/-0.0318 0.0524 pCi/g Cesium-137 0.192 +/-0.0408 0.0197 +/-0.0408 0.0414 pCi/g Cobalt-60 0.522 +/-0.0639 0.0211 +/-0.0639 0.0453 pCi/g Europium-152 U -0.0379 +/-0.0596 0.0464 +/-0.0596 0.0966 pCi/g Europium-154 U -0.0318 +/-0.0732 0.0585 +/-0.0732 0.126 pCi/g Europium-155 U 0.0641 +/-0.0925 0.0488 +/-0.0925 0.100 pCi/g Lead-212 1.14 +/-0.0696 0.0264 +/-0.0696 0.0544 pCi/g Lead-214 0.753 +/-0.0911 0.0337 +/-0.0911 0.070 pCi/g Manganese-54 U 0.0134 +/-0.0217 0.0193 +/-0.0217 0.0408 pCi/g Niobium-94 U 0.0073 +/-0.0216 0.0181 +/-0.0216 0.038 pCi/g Potassium-40 17.9 +/-1.02 0.190 +/-1.02 0.412 pCi/g Radium-226 0.626 +/-0.101 0.0371 +/-0.101 0.0775 pCi/g Silver-108m U 0.00496 +/-0.0191 0.0165 +/-0.0191 0.0344 pCi/g Thallium-208 0.354 +/-0.0504 0.0183 +/-0.0504 0.0384 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00471 +/-0.0144 0.0114 +/-0.0145 0.027 pCi/g KSD1 09/07/06 1758 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOC Project: YANKO 1204 Sample ID: 170256007 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits CarrierFIracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25°/w- 125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UlI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010D Proiect: YANK01204 Sample ID: 170256008 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 58.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.920 +/-0.431 0.163 +/-0.431 0.345 pCi/g MJHI 09/01/06 1222 563436 1 Americium-241 U 0.159 +/-0.0868 0.0423 +/-0.0868 0.0871 pCi/g Bismuth-212 0.975 +/-0.615 0.310 +/-0.615 0.654 pCi/g Bismuth-214 U1 0.00 +/-0.170 0.126 +/-0.170 0.259 pCi/g Cesium-134 UI 0.00 +/-0.0619 0.0563 +/-0.0619 0.118 pCi/g Cesium-137 0.630 +/-0.105 0.037 +/-0.105 0.0784 pCi/g Cobalt-60 2.24 +/-0.161 0.0361 +/-0.161 0.0793 pCi/g Europium-152 U 0.0801 +/-0.100 0.0874 +/-0.100 0.182 pCi/g Europium-154 U 0.159 +/-0.180 0.124 +/-0.180 0.267 pCi/g Europium-155 U 0.0923 +/-0.117 0.0649 +/-0.117 0.134 pCi/g Lead-212 1.10 +/-0.108 0.0414 +/-0.108 0.086 pCi/g Lead-214 0.707 +/-0.194 0.0578 +/-0.194 0.121 pCi/g Manganese-54 U 0.0291 +/-0.050 0.0419 +/-0.050 0.0886 pCi/g Niobium-94 U 0.0114 +/-0.0446 0.0367 +/-0.0446 0.0774 pCi/g Potassium-40 16.4 +/-1.57 0.341 +/- 1.57 0.753 pCi/g Radium-226 0.761 +/-0.170 0.0744 +/-0.170 0.156 pCi/g Silver-108m U 0.00643 +/-0.0377 0.0316 +/-0.0377 0.0662 pCi/g Thallium-208 0.396 +/-0.103 0.0362 +/-0.103 0.0763 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium- 9 0 U 0.0219 +/-0.0196 0.0135 +/-0.0196 0.0315 pCi/g KSD1 09/07/06 1805 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOD Project: YANKO 1204 Sample ID: 170256008 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 97 (25%- 125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033A Project: YANKO 1204 Sample ID: 170256009 Client ID: YANKOO 1 Matrix: SE Vol. Recv.:

Collect Date: 1I-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 26.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 +/-0.272 0.0796 +/-0.272 0.171 pCi/g MJI-ll 09/01/06 1223 563436 1 Americium-241 U 0.0199 +/-0.0632 0.0541 +/-0.0632 0.112 pCi/g Bismuth-212 UI 0.00 +/-0.484 0.171 +/-0.484 0.363 pCi/g Bismuth-214 0.920 +/-0.139 0.0421 +/-0.139 0.089 pCi/g Cesium-134 U 0.0188 +/-0.0338 0.0298 +/-0.0338 0.0628 pCi/g Cesium-137 0.709 +/-0.0983 0.0246 +/-0.0983 0.0519 pCi/g Cobalt-60 0.697 +/-0.0935 0.0267 +/-0.0935 0.0577 pCi/g Europium-152 U -0.0119 /-0.0643 0.0538 +/-0.0643 0.113 pCi/g Europium- 154 U 0.0763 /-0.0741 0.0675 +/-0.0741 0.147 pCi/g Europium-155 UI 0.00 /-0.0951 0.052 +/-0.0951 0.108 pCi/g Lead-212 1.13 +/-0.134 0.0457 +/-0.134 0.0938 pCi/g Lead-214 1.04 +/-0.151 0.0416 +/-0.151 0.0871 pCi/g Manganese-54 U -0.0049 d-/-0.0275 0.023 +/-0.0275 0.049 pCi/g Niobium-94 U 0.014 -/-0.0236 0.0211 +/-0.0236 0.0446 pCi/g Potassium-40 14.3 +/-1.30 0.185 +/-1.30 0.412 pCi/g Radium-226 0.920 +/-0.139 0.0421 +/-0.139 0.089 pCi/g Silver-108m U3.080E-05 +-/-0.0263 0.0202 +/-0.0263 0.0424 pCi/g Thallium-208 0.405 +/-0.066 0.0235 +/-0.066 0.0495 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 0.0366 +-/-0.0205 0.0124 +/-0.0205 0.0291 pCi/g KSDI 09/07/06 1807 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033A Project: YANKO1204 Sample ID: 170256009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria
  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033B Prolect: YANKO 1204 Sample ID: 170256010 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 11-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 16.3%

Parameter (:ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.272 0.113 +/-0.272 0.225 pCi/g MJHIl 09/01/06 1559 563436 1 Americium-241 U 0.037 +/-0.0519 0.0353 +/-0.0519 0.0705 pCi/g Bismuth-212 0.897 +/-0.563 0.237 +/-0.563 0.473 pCi/g Bismuth-214 0.681 +/-0.143 0.057 +/-0.143 0.114 pCi/g Cesium-134 U 0.062 +/-0.0748 0.0371 +/-0.0748 0,0742 pCi/g Cesium-137 0.862 +/-0.117 0.0301 +/-0.117 0,0601 pCi/g Cobalt-60 0.944 +/-0.113 0.0281 +/-0.113 0,0562 pCi/g Europium-152 U 0.00733 +/-0.118 0.0695 +/-0.118 0.139 pCi/g Europium-154 U 0.00812 +/-0.115 0.0959 +1-0.115 0.192 pCi/g Europium-155 U 0.0592 +/-0.0677 0.0595 +/-0.0677 0.119 pCi/g Lead-212 0.896 +/-0.109 0.0377 +/-0.109 0.0754 pCi/g Lead-214 0.773 +/-0.141 0.0491 +/-0.141 0.0981 pCi/g Manganese-54 U -0.0465 +/-0.0487 0.032 +/-0.0487 0.0639 pCi/g Niobium-94 U 0.00334 +/-0.0333 0.029 +/-0.0333 0.0579 pCi/g Potassium-40 11.6 +/-1.25 0.247 +/- 1.25 0.494 pCi/g Radium-226 0.681 +/-0.143 0.057 +/-0.143 0.114 pCi/g Silver-108m U -0.00313 +/-0.0324 0.0274 +/-0.0324 0.0548 pCi/g Thallium-208 0.278 +/-0.0682 0.0296 +/-0.0682 0.0592 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00794 +1-0.015 0.0113 +1-0.015 0.0268 pCi/g KSDI 09/07/06 1807 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033B Proiect: YANK01204 Sample ID: 170256010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-9125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033C Proiect: YANK01204 Sample ID: 170256011 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 1 1-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 14.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.841 +/-0.277 0.100 +/-0.277 0.212 pci/g MJH1 09/01/06 1829 563436 1 Americium-241 U 0.028 +/-0.048 0.0331 +/-0.048 0.068 pCi/g Bismuth-212 0.476 +/-0.345 0.223 +/-0.345 0.468 pCi/g Bismuth-214 0.628 +/-0.128 0.0439 +/-0.128 0.0928 pCi/g Cesium-134 U 0.0398 +/-0.0385 0.0344 +/-0.0385 0.0721 pCi/g Cesium-137 0.609 +/-0.0698 0.0277 +/-0.0698 0.0581 pCi/g Cobalt-60 0.916 +/-0.0989 0.0255 +/-0.0989 0.0552 pci/g Europium-152 U -0.0803 +/-0.0732 0.0581 +/-0.0732 0.121 pCi/g Europium-154 U -0.0175 +/-0.0895 0.0738 +/-0.0895 0.159 pCi/g Europium-155 U 0.0335 +/-0.0642 0.0553 +/-0.0642 0.114 pCi/g Lead-212 0.710 +/-0.0819 0.0392 +/-0.0819 0.0808 pCi/g Lead-214 0.810 +/-0.110 0.0428 +/-0.110 0.0895 pCi/g Manganese-54 U -0.0149 +/-0.0338 0.0272 +/-0.0338 0.0575 pCi/g Niobium-94 U -0.00772 +/-0.0304 0.0254 +/-0.0304 0.0533 pCi/g Potassium-40 11.0 +/-1.00 0.220 +/-1.00 0.484 pCi/g Radium-226 0.628 +/-0.128 0.0439 +/-0.128 0.0928 pCi/g Silver-108m U 0.0295 +/-0.0254 0.0239 +/-0.0254 0.0499 pCi/g Thallium-208 0.237 +/-0.0761 0.0244 +/-0.0761 0.0513 pci/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontiurn-90 U -0.0326 +/-0.013 0.0158 +/-0.013 0.0359 pCi/g KSDI 09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033C Project: YANK01204 Sample ID: 170256011 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 90 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, NyDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033D Proiect: YANK01204 Sample ID: 170256012 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 1I-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 11.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.800 +/-0.169 0.0584 +/-0.169 0.125 pCi/g MJHI 09/05/06 0531 563436 1 Americium-241 U -0.00757 +/-0.0849 0.0733 +/-0.0849 0.151 pCi/g Bismuth-212 0.514 +/-0.239 0.125 +/-0.239 0.265 pCi/g Bismuth-214 0.496 +/-0.079 0.0289 +/-0.079 0.0614 pCi/g Cesium-134 UI 0.00 +/-0.0333 0.0215 +/-0.0333 0.0454 pCi/g Cesium-137 0.240 +/-0.0466 0.0172 +/-0.0466 0.0365 pCi/g Cobalt-60 0.329 +/-0.0616 0.0159 +/-0.0616 0.0349 pCi/g Europium-152 U -0.0221 +/-0.047 0.0418 +/-0.047 0.0875 pCi/g Europium-154 U -0.0277 +/-0.0651 0.0444 +/-0.0651 0.0974 pCi/g Europium-155 U 0.0409 +/-0.050 0.0464 +/-0.050 0.0959 pCi/g Lead-212 0.618 +/-0.0549 0.0246 +/-0.0549 0.0511 pCi/g Lead-214 0.582 +/-0.0773 0.0304 +/-0.0773 0.0635 pCi/g Manganese-54 U 0.0209 +/-0.0191 0.0165 +/-0.0191 0.0352 pCi/g Niobium-94 U 0.0124 +/-0.0174 0.0157 +/-0.0174 0.0331 pCi/g Potassium-40 10.8 +/-0.796 0.144 +/-0.796 0.320 pCi/g Radiumn-226 0.496 +/-0.079 0.0289 +/-0.079 0.0614 pCi/g Silver-108m U -0.00363 +/-0.0168 0.0148 +/-0.0168 0.0312 pCi/g Thallium-208 0.222 +/-0.040 0.0156 +/-0.040 0.033 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.020 +/-0.0174 0.0117 +/-0.0174 0.0276 pCi/g KSDI 09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033D Project: YANKO1204 Sample ID: 170256012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/[racer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013A Project: YANKO 1204 Sample ID: 170256013 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 17.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 lngrowth Waived Actinium-228 1.15 +/-0.162 0.0511 +/-0.162 0.109 pCi/g MJHI 09/01/06 1830 563436 1 Americium-241 U 0.0596 +/-0.0865 0.0665 +/-0.0865 0.136 pCi/g Bismtth-212 0.731 +/-0.295 0.115 +/-0.295 0.242 pCi/g Bismuth-214 0.959 +/-0.0845 0.0284 +/-0.0845 0.0597 pCi/g Cesium-134 UI 0.00 +/-0.0287 0.0195 +/-0.0287 0.041 pCi/g Cesium-137 U -0.00113 +/-0.0196 0.0162 +/-0.0196 0.034 pCi/g Cobalt-60 U -0.00569 +/-0.0174 0.0139 +/-0.0174 0.0301 pCi/g Europium-152 U -0.0275 +/-0.0539 0.0402 +/-0.0539 0.0837 pCi/g Europium-154 U -0.0292 +/-0.0495 0.0385 +/-0.0495 0.0835 pCi/g Europium-155 U 0.0375 +/-0.0594 0.0534 +/-0.0594 0.110 pCi/g Lead-212 1.19 +/-0.0671 0.0261 +/-0.0671 0.0537 pCi/g Lead-214 1.08 +/-0.090 0.0305 +/-0.090 0.0634 pCi/g Manganese-54 U 0.0199 +/-0.0202 0.0165 +/-0.0202 0.0347 pCi/g Niobium-94 U -6.020E- +/-0.0164 0.0143 +/-0.0164 0.030 pCi/g 05 Potassium-40 14.3 +/-0.771 0.130 +/-0.771 0.283 pCi/g Radium-226 0.959 +/-0.0845 0.0284 +/-0.0845 0.0597 pCi/g Silver-108m U - 0.00566 +/-0.0152 0.0128 +/-0.0152 0.0268 pCi/g Thallium-208 0.423 +/-0.0539 0.0142 +/-0.0539 0.030 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.00331 +1-0.0151 0.0131 +/-0.0151 0.0304 pCi/g KSD1 .09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 2 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013A Project: YANKO 1204 Sample ID: 170256013 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25o-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Ana1vqiv Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013B Prolect: YANK01204 Sample ID: 170256014 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 19.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.23 +/-0.302 0.0948 +/-0.302 0.190 pCi/g MJHI 09/01/06 2110 563436 1 Americium-241 U 0.0581 +/-0.0456 0.0383 +/-0.0456 0.0765 pCi/g Bismuth-212 0.606 +/-0.361 0.199 +/-0.361 0.399 pCi/g Bismuth-214 0.990 +/-0.154 0.046 +/-0.154 0.0919 pCi/g Cesium-134 U 0.0447 +/-0.0383 0.033 +/-0.0383 0.066 pCi/g Cesium-137 0.0831 +/-0.037 0.0286 +/-0.037 0.0571 pCi/g Cobalt-60 0.196 F/-0.0645 0.0258 +/-0.0645 0.0515 pCi/g Europium-152 U 0.0248 +/-0.116 0.061 +/-0.116 0.122 pCi/g Europium-154 U 0.0401 +/-0.106 0.0809 +/-0.106 0.162 pCi/g Europium-155 U 0.067 +/-0.0826 0.0584 +/-0.0826 0.117 pCi/g Lead-212 1.32 +/-0.136 0.0337 +/-0.136 0.0674 pCi/g Lead-214 0.989 +/-0.153 0.0431 +/-0.153 0.0862 pCi/g Manganese-54 U -0.00696 +/-0.0306 0.0262 +/-0.0306 0.0523 pCi/g Niobium-94 U 0.00306 +/-0.0256 0.0228 +/-0.0256 0.0455 pCi/g 4 +/-0.996 +/-0.996 Potassium- 0 9.89 0.207 0.414 pCi/g Radium-226 0.990 +/-0.154 0.046 +/-0.154 0.0919 pCi/g Silver-108m U -0.017 +/-0.0253 0.0211 +/-0.0253 0.0422 pCi/g Thallium-208 0.456 +/-0.084 0.0253 +/-0.084 0.0505 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00221 /-0.0172 0.0143 +/-0.0172 0.0316 pCi/g KSDI 09/07/06 1843 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013B Proiect: YANKO1204 Sample ID: 170256014 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013C Project: YANKO 1204 Sample ID: 170256015 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 17.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 +/-0.236 0.0703 +/-0.236 0.154 pCi/g MJH1 09/01/062118 563436 1 Americium-241 U - -0.00337 +/-0.0367 0.034 +/-0.0367 0.0701 pCi/g Bismuth-212 0.808 +/-0.311 0.157 +/-0.311 0.341 pCi/g Bismuth-214 0.614 +/-0.118 0.0422 +/-0.118 0.0899 pCi/g Cesium-134 U 0.0481 +/-0.0502 0.033 +/-0.0502 0.0699 pCi/g Cesium- 137 0.0789 +/-0.0569 0.0226 +/-0.0569 0.0484 pCi/g Cobalt-60 0.074 +/-0.0564 0.0239 +/-0.0564 0.0531 pCi/g Europium-152 U -0.0203 +/-0.0622 0.0547 +/-0.0622 0.115 pCi/g Europium-154 U -0.0129 +/-0.0828 0.0688 +/-0.0828 0.152 pCi/g Europium-155 U 0.0479 +/-0.0527 0.0529 +/-0.0527 0.109 pCi/g Lead-212 0.903 +/-0.0714 0.0332 +/-0.0714 0.069 pCi/g Lead-214 0.651 +/-0.103 0.0431 +/-0.103 0.0904 pCi/g Manganese-54 U -0.0163 +/-0.0298 0.0235 +/-0.0298 0.0506 pCi/g Niobium-94 U -0.022 +/-0.0284 0.0226 +/-0.0284 0.0481 pCi/g Potassium-40 12.9 +/-1.11 0.250 +/-1.11 0.553 pCi/g Radium-226 0.614 +/-0.118 0.0422 +/-0.118 0.0899 pCi/g Silver-108m U 0.00256 +/-0.0199 0.0177 +/-0.0199 0.0378 pCi/g Thallium-208 0.248 +/-0.0569 0.0239 +/-0.0569 0.0508 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U - 0.00157 +/-0.0143 0.0123 +/-0.0143 0.0289 pCi/g KSD1 09/07/06 1845 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013C Proiect: YANKO1204 Sample ID: 170256015 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 98 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldoI-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013D Proiect: YANK01204 Sample ID: 170256016 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 25.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.160 0.0664 +/-0.160 0.142 pCi/g MJHI 09/05/06 0521 563436 1 Americium-241 U 0.0216 +/-0.0981 0.0845 +/-0.0981 0.174 pCi/g Bismuth-212 0.420 +/-0.350 0.142 +/-0.350 0.301 pCi/g Bismuth-214 0.689 +/-0.0898 0.0339 +/-0.0898 0.0715 pCi/g Cesium-134 U 0.0488 +/-0.0307 0.0247 +/-0.0307 0.0519 pCi/g Cesium-137 0.170 +/-0.0491 0.019 +/-0.0491 0.0402 pCi/g Cobalt-60 0.566 +/-0.0694 0.0198 +/-0.0694 0.0431 pCi/g Europium-152 U 0.0265 +/-0.0524 0.0453 +/-0.0524 0.0946 pCi/g Europium-154 U 0.0628 +/-0.0639 0.0591 +/-0.0639 0.127 pCi/g Europium-155 U 0.0541 +/-0.0561 0.0528 +/-0.0561 0.109 pCi/g Lead-212 0.958 +/-0.0653 0.0265 +/-0.0653 0.055 pCi/g Lead-214 0.784 +/-0.0896 0.0297 +/-0.0896 0.0623 pCi/g Manganese-54 U 0.00917 +/-0.0221 0.019 +/-0.0221 0.0403 pCi/g Niobium-94 U 0.0056 +/-0.019 0.0164 +/-0.019 0.0347 pCi/g Potassium-40 12.6 +/-0.931 0.166 +/-0.931 0.367 pCi/g Radium-226 0.689 +/-0.0898 0.0339 +/-0.0898 0.0715 pCi/g Silver-108m U -0.00656 +/-0.0175 0.0151 +/-0.0175 0.0318 pCi/g Thallium-208 0.314 +/-0.0426 0.0189 +/-0.0426 0.0398 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00738 +/-0.0147 0.0112 +/-0.0147 0.0265 pCi/g KSD1 09/07/06 1846 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013D Project: YANKO 1204 Sample ID: 170256016 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 106 (25%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005A Project: YANK01204 Sample ID: 170256017 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 09-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 17.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.975 +/-0.164 0.0814 +/-0.164 0.174 pCi/g MJH1 09/01/062119 563436 1 Americium-241 U 0.0504 +/-0.0306 0.030 +/-0.0306 0.0616 pCi/g Bismuth-212 0.804 +/-0.393 0.165 +/-0.393 0.351 pCi/g Bismuth-214 0.647 +/-0.112 0.0371 +/-0.112 0.0787 pCi/g Cesium-134 U 0.0288 +/-0.0288 0.0271 +/-0.0288 0.0574 pCi/g Cesium-137 0.249 +/-0.0491 0.0255 +/-0.0491 0.0537 pCi/g Cobalt-60 0.682 +/-0.0884 0.0206 +/-0.0884 0.0453 pCi/g Europium- 152 U 0.0893 +/-0.0683 0.0526 +/-0.0683 0.110 pCi/g Europium-154 U 0.0167 +/-0.0707 0.0611 +/-0.0707 0.134 pCi/g Europium-155 U 0.00619 +/-0.0524 0.0476 +/-0.0524 0.0982 pCi/g Lead-212 0.912 +/-0.0658 0.0281 +/-0.0658 0.0584 pCi/g Lead-214 0.747 +/-0.0939 0.036 +/-0.0939 0.0755 pCi/g Manganese-54 U 0.0235 +/-0.0494 0.0228 +/-0.0494 0.0486 pCi/g Niobium-94 U -0.00608 +/-0.0244 0.0201 +/-0.0244 0.0426 pCi/g Potassium-40 10.5 +/-0.910 0.155 +/-0.910 0.351 pCi/g Radium-226 0.647 +/-0.112 0.0371 +/-0.112 0.0787 pCi/g Silver-108m U 0.00189 +/-0.0202 0.0178 +/-0.0202 0.0376 pCi/g Thallium-208 0.322 +/-0.0462 0.0209 +/-0.0462 0.0442 pCi/g Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.00262 +/-0.0137 0.012 +/-0.0137 0.0286 pCi/g KSD1 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005A Project: YANK01204 Sample ID: 170256017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 92 (25/-,125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005B Proiect: YANK01204 Sample ID: 170256018 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 10-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 14%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS CAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.787 +/-0.187 0.0725 +/-0.187 0.153 pCi/g MJHI 09/02/06 1713 563436 1 Americium-241 U 0.0759 +/-0.0649 0.0382 +/-0.0649 0.0789 pCi/g Bismuth-212 0.403 +/-0.233 0.139 +/-0.233 0.294 pCi/g Bisnmuth-214 0.636 +/-0.108 0.0306 +/-0.108 0.0647 pCi/g Cesium-134 U 0.0378 +/-0.0274 0.0229 +/-0.0274 0.0482 pCi/g Cesium-137 0.181 +/-0.0421 0.019 +/-0.0421 0.040 pCi/g Cobalt-60 0.710 +/-0.0716 0.0155 +/-0.0716 0.034 pCi/g Europium-152 U 0.0183 +/-0.0466 0.0421 +/-0.0466 0.0881 pCi/g Europium-154 U 0.0204 +/-0.0516 0.0449 +/-0.0516 0.0982 pCi/g Europium-155 UI 0.00 +/-0.0804 0.0458 +/-0.0804 0.0944 pCi/g Lead-212 0.722 +/-0.086 0.0317 +/-0.086 0.0651 pCi/g Lead-214 0.832 +/-0.115 0.0288 +/-0.115 0.0605 pCi/g Manganese-54 U 0.0204 +/-0.0232 0.0192 +/-0.0232 0.0406 pCi/g Niobium-94 U 0.0129 +/-0.0173 0.0161 +/-0.0173 0.0339 pCi/g Potassium-40 9.30 +/-0.895 0.130 +/-0.895 0.291 pCi/g Radium-226 0.636 +/-0.108 0.0306 +/-0.108 0.0647 pCi/g Silver-108m U 0.0081 +/-0.0194 0.0154 +/-0.0194 0.0324 pCi/g Thallium-208 0.299 +1-0.0505 0.0157 +1-0.0505 0.0332 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0109 +/-0.0167 0.0123 +/-0.0167 0.0293 pCi/g KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005B Project: YANKO 1204 Sample ID: 170256018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 95 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005C Proiect: YANKO 1204 Sample ID: 170256019 Client ID: YANKO0I Matrix: SE Vol. Recv.:

Collect Date: 10-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: 24.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.810 +/-0.116 0.0431 +/-0.116 0.090 pCi/g MJH1 09/05/06 2143 563436 1 Americium-241 U 0.0147 +/-0.0176 0.0169 +/-0.0176 0.0345 pCi/g Bismuth-212 0.365 +/-0.171 0.099 +/-0.171 0.206 pCi/g Bismuth-214 0.623 +/-0.0633 0.0212 +/-0.0633 0.044 pCi/g Cesium-134 UI 0.00 +/-0.0297 0.0166 +/-0.0297 0.0343 pCi/g Cesium-137 0.113 +/-0.0242 0.0124 +/-0.0242 0.0257 pCi/g Cobalt-60 0.268 +/-0.0379 0.012 +/-0.0379 0.0254 pCi/g Europium-152 U -0.00617 +/-0.0317 0.0284 +/-0.0317 0.0585 pCi/g Europium-154 U -0.0248 +/-0.0417 0.0337 +/-0.0417 0.0714 pCi/g Europium-155 UI 0.00 +/-0.0407 0.0265 +/-0.0407 0.054 pCi/g Lead-212 0.840 +/-0.0404 0.0162 +/-0.0404 0.0332 pCi/g Lead-214 0.686 +/-0.0505 0.0197 +1-0.0505 0.0406 pCi/g Manganese-54 U 0.00306 +/-0.0143 0.0127 +/-0.0143 0.0265 pCi/g Niobium-94 U 0.0053 +/-0.013 0.0112 +/-0.013 0.0232 pCi/g Potassium-40 10.2 +/-0.535 0.0857 +/-0.535 0.186 pCi/g Radium-226 0.623 +/-0.0633 0.0212 +/-0.0633 0.044 pCi/g Silver-108m U -0.0071 +/-0.0113 0.00971 +/-0.0113 0.0201 pCi/g Thallium-208 0.288 +/-0.031 0.0115 +/-0.031 0.0239 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0082 +/-0.0158 0.012 +/-0.0158 0.0284 pCi/g KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005C Project: YANKO 1204 Sample ID: 170256019 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%-0125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005D Proiect: YANKO 1204 Sample ID: 170256020 Client ID: YANKOO Matrix: SE Vol. Recv.:

Collect Date: 10-AUG-06 Receive Date: 25-AUG-06 Collector: Client Moisture: .19.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.995 +/-0.411 0.146 +/-0.411 0.291 pCi/g MJH1 09/02/06 1725 563436 1 Americium- 2 4 1 U 0.0557 +/-0.0479 0.0365 +/-0.0479 0.0729 pCi/g Bismuth-212 0.635 +/-0.589 0.261 +/-0.589 0.521 pCi/g Bismuth-214 0.760 +/-0.165 0.0601 +/-0.165 0.120 pCi/g Cesium- 134 U 0.0627 +1-0.0504 0.0463 +/-0.0504 0.0926 pCi/g Cesium-137 0.503 +/-0.0894 0.0338 +/-0.0894 0.0676 pCi/g Cobalt-60 1.72 +/-0.132 0.0307 +/-0.132 0.0614 pCi/g Europium-152 U 0.00265 +/-0.0988 0.0745 +/-0.0988 0.149 pCi/g Europium-154 U 0,0538 +/-0.114 0.0996 +/-0.114 0.199 pCi/g Europium-155 UI 0.00 +/-0.119 0.0591 +/-0.119 0.118 pCi/g Lead-212 1.09 +/-0.126 0.0386 +/-0.126 0.0772 pCi/g Lead-214 0.802 +/-0.135 0.0517 +/-0.135 0.103 pCi/g Manganese-54 U 0.0185 +/-0.0434 0.0383 +/-0.0434 0.0766 pCi/g Niobium-94 U -0.0168 +/-0.0366 0.0309 +/-0.0366 0.0618 pCi/g Potassium- 4 0 10.7 +/-1.11 0.276 +/-1.11 0.551 pCi/g Radium-226 0.760 +/-0.165 0.0601 +/-0.165 0.120 pCi/g Silver-108m U -0.021 +/-0.0301 0.0247 +/-0.0301 0.0494 pCi/g Thallium-208 0.343 +/-0.0887 0.0298 +/-0.0887 0.0595 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U - -0.00322 +/-0.0146 0.0127 +/-0.0146 0.0299 pCi/g KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005D Project: YANKO 1204 Sample ID: 170256020 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

I QUALITY CONTROL DATA 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: September 8, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 5 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 170256 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 563436 QC1201171526 170256001 DUP Actinium-228 0.966 1.01 pCi/g 4 (0%- 100%) MJHI 09/02/06 17:26 Uncert: +/-0.192 +/-0.200 TPU: +/-0.192 +/-0.200 Americium-241 U 0.0375 U 0.0258 pCi/g 37 (0% - 100%)

Uncert: +/-0.0387 +/-0.075 TPU: +/-0.0387 +/-0.075 Bismuth-212 0.366 0.592 pCi/g 47 (0%- 100%)

Uncert: +/-0.306 +/-0.276 TPU: +/-0.306 +/-0.276 Bismuth-214 0.650 0.690 pCi/g 6 (0%- 100%)

Uncert: +/-0.135 +/-0.0955 TPU: +/-0.135 +/-0.0955 Cesium- 134 U 0.0366 UI 0.00 pCi/g 56 (0%- 100%)

Uncert: +/-0.0355 +/-0.035 TPU: +/-0.0355 +/-0.035 Cesium- 137 0.0666 0.0611 pCi/g 9 (0% - 100%)

Uncert: +/-0.0355 +/-0.0415 TPU: +/-0.0355 +/-0.0415 Cobalt-60 0.104 0.159 pCi/g 41 (0% - 100%)

Uncert: +/-0.0726 +/-0.0325 TPU: +/-0.0726 +/-0.0325 Europium- 152 U 0.00636 U -0.00858 pCi/g 1350 (0%- 100%)

Uncert: +/-0.0728 +/-0.0624 TPU: +/-0.0728 +/-0.0624 Europium- 154 U -0.0788 U 0.00919 pCi/g 253 (0%- 100%)

Uncert: +/-0.0938 +/-0.0602 TPU: +/-0.0938 +/-0.0602 Europium- 155 U 0.0672 U 0.0817 pCi/g 20 (0%- 100%)

Uncert: +/-0.0554 +/-0.0557 TPU: +/-0.0554 +/-0.0557 Lead-212 0.871 0.847 pCi/g 3 (0%- 20%)

Uncert: +/-0.0971 +/-0.0867 TPU: +/-0.0971 +/-0.0867 Lead-214 0.727 0.699 pCi/g 4 (0%-20%)

Uncert: +/-0.105 +/-0.102 TPU: +1-0.105 +/-0.102 Manganese-54 U -0.00916 U -0.00665 pCi/g 32 (0%- 100%)

Uncert: +/-0.0319 +/-0.0225 TPU: +/-0.0319 +/-0.0225 Niobium-94 U 0.0101 U -0.00339 pCi/g 402 (0%- 100%)

Uncert: +/-0.0244 +/-0.0176 TPU: +/-0.0244 +/-0.0176 61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 170256 Page 2 of 5 Parmname NOM Samole Oual OC Units RPD% REC% Rane AnIst Date Time.

Rad Gamma Spec Batch 563436 Potassium-40 11.3 11.7 pCi/g 3 (0% - 20%)

Uncert: +/-0.986 +/-1.03 TPU: +/-0.986 +/-1.03 Radium-226 0.650 0.690 pCi/g 6 (0%- 100%)

Uncert: +/-0.135 +/-0.0955 TPU: +/-0.135 +/-0.0955 Silver-] 08m u -0.0067 U 0.000104 pCi/g 206 (0%- 100%)

Uncert: +/-0.0208 +/-0.018 TPU: +/-0.0208 +/-0.018 Thallium-208 0.283 0.283 pCi/g 0 (0%- 100%)

Uncert: +/-0.0618 +/-0.048 TPU: +/-0.0618 +/-0.048 LCS Actinium-228 U 0.254 pCi/g 09/03/06 22:31 Uncert: +/-0.565 TPU: +/-0.565 Americium-24 I 23.4 24.1 pCi/g 103 (75%-125%)

Uncert: +/-1.28 TPU: +/-1 .28 Bismuth-212 U 0.575 pCi/g Uncert: +/-0.944 TPU: +/-0.944 Bismuth-214 U 0.0248 pCi/g Uncert: +/-0.213 TPU: +/-0.213 Cesium- 134 U 0.00032 pCi/g Uncert: +/-0.147 TPU: +/-0.147 Cesium-137 9.58 9.84 pCi/g 103 (75%-125%)

Uncert: +/-0.487 TPU: +/-0.487 Cobalt-60 14.5 14.7 pCi/g 101 (75%-125%)

Uncert: +/-0.660 TPU: +/-0.660 Europium- 152 U 0.125 pCi/g Uncert: +/-0.292 TPU: +/-0.292 Europium- 154 U 0.0779 pCi/g Uncert: +/-0.277 TPU: +/-0.277 Europium- 155 U -0.0876 pCi/g Uncert: +/-0.277 TPU: +/-0.277 Lead-212 U 0.0524 pCi/g Uncert: +/-0.155 TPU: +/-0.155 Lead-2I4 U -0.103 pCi/g Uncert: +/-0.212 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder: 170256 Page 3 of 5 Parmname NOM Sample Oual OC Units RPD% REC% Ran2e Anist Date Time Rad Gamma Spec Batch 563436 TPU: +/-0.212 Manganese-54 U 0.0306 pCi/g Uncert: +/-0.135 TPU: +/-0.135 Niobium-94 U -0.0513 pCi/g Uncert: +/-0.115 TPU: +/-0.115 Potassium-40 U 0.769 pCi/g Uncert: +/-1.10 TPU: +/-1.10 Radium-226 U 0.0248 pCi/g (75%- 125%)

Uncert: +/-0.213 TPU: +/-0.213 Silver- 108m U 0.0782 pCi/g Uncert: +1-0.105 TPU: +1-0.105 Thallium-208 U 0.180 pCi/g Uncert: +/-0.177 TPU: +/-0.177 QCI201171525 MB Actinium-228 U 0.0216 pCi/g 09/02/06 17:16 Uncert: +/-0.0479 TPU: +/-0.0479 Americium-241 U -0.0654 pCi/g Uncert: +/-0.0396 TPU: +/-0.0396 Bismuth-212 U 0.110 pCi/g Uncert: +/-0.0705 TPU: +/-0.0705 Bismuth-214 U 0.00843 pCi/g Uncert: +/-0.0317 TPU: +/-0.0317 Cesium- 134 U -0.00203 pCi/g Uncert: +/-0.012 TPU: +/-0.012 Cesium- 137 U -0.00757 pCi/g Uncert: +/-0.0117 TPU: +/-0.0117 Cobalt-60 U -0.00589 pCi/g Uncert: +/-0.0128 TPU: +/-0.0128 Europium-I152 U -0.0169 pCi/g Uncert: +/-0.0308 TPU: +/-0.0308 Europium- 154 U 0.00802 pCi/g Uncert: +/-0.0305 TPU: +/-0.0305 Europium- 155 U -0.00342 pCi/g 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 170256 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 563436 Uncert: +/-0.0294 TPU: +/-0.0294 Lead-212 U 0.0151 pCi/g Uncert: +/-0.028 TPU: +/-0.028 Lead-214 U 0.00738 pCi/g Uncert: +/-0.0252 TPU: +/-0.0252 Manganese-54 U 0.0127 pCi/g Uncert: +/-0.0111 TPU: +/-0.0111 Niobium-94 U -0.00293 pCi/g Uncert: +/-0.012 TPU: +/-0.012 Potassium-40 U 0.112 pCi/g Uncert: +/-0.173 TPU: +/-0.173 Radium-226 U 0.00843 pCi/g Uncert: +/-0.0317 TPU: +/-0.0317 Silver- 108m U 0.00354 pCi/g Uncert: +/-0.0115 TPU: +/-0.0115 Thallium-208 U -0.011 pCi/g Uncert: +/-0.0157 TPU: +/-0.0157 Rad Gas Flow Batch 562563 QC1201169422 170256002 DUP Strontium-90 U 0.00501 U 0.00534 pCi/g 0 (0%- 100%) KSDI 09/07/06 18:59 Uncert: +/-0.0149 +/-0.0155 TPU: +/-0.0149 +1-0.0155 QC1201169424 LCS Strontium-90 1.74 1.57 pCi/g 90 (75%-125%) 09/07/06 19:16 Uncert: +/-0.140 TPU: +/-0.147 QC1201169421 MB Strontium-90 U 0.0172 pCi/g 09/07/06 18:59 Uncert: +/-0.0185 TPU: +/-0.0185 QC1201169423 170256002 MS Strontium-90 1.74 U 0.00501 1.32 pCi/g 76 (75%-125%) 09/07/06 19:16 Uncert: +/-0.0149 +/-0.124 TPU: +/-0.0149 +/-0.130 Notes:

The Qualifiers in this report are defined as follows:

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 170256 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded I Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

" The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

65

General Narrative Page 1 of 105

CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address:

P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:

2040 Savage Road Charleston, South Carolina 29407 Telephone Number:

(843) 556-8.171 Summary:

Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.

P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)

Page 2 of 105 Phone (843) 556-8171

  • Fax (843) 766-1178
  • www.gel.com

168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F Items of Note:

At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.

Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request:

Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.

Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.

Two soil samples were reanalyzed for FSSALL, except gamma.

Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.

Internal Chain of Custody:

Custody was maintained for the sample(s).

Data Package:

The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.

PO. Box 30712

  • Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105 I I!

Additional HTD analyses

Subject:

Additional HTD analyses 1(.,gLi(oc, '

From: "Dale Randall" <randall @cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.corn>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@ CYAPCO.com>

Cheryl:

Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol. I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description: GEL FSSALL analyses request.xls GEL FSSALL analyses request.xls Content-Type: application/vrid.mns-excel

'Content-Encoding: base64 I of I Page 4 of 105 8/2/2006 7:04 PM

Done To be done Previous GEL ID CY sample location IDs FSS Gam Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C 164220008 9106-0002-007F x x x x x x x x x x 164220012 9106-0002-o011F x x __x x x x x x x x o 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832009 9106-0004-015F x x x x x x x x x x 162485008 9106-0005-01OF x x x x x x x x x x 162485011 9106-0005-014F x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x X x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 9106-0010-001iF x x x X- x x x X

_ Xx 163105016 9106-0010-012F x x x x x x x x x x

Chain of Custody and Supporting Documentation Page 6 of 105

ffo 5qolý Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major

-t (b Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 362 Injun Hollow Road, East Hampton, CT 06424 C

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c M 4 Priority: Z 30 D. [] 14 D. [] 7 D.

Sample Container Size- \QLA*i* c ft Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OOIF 5/17/06 10:42 SE C BP X X .Transferred fromn COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP x Transtrred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred fror COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x -"Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X _ x Transferred fron COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x - -Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X" Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA LTP U QA [I Radwaste QA El Non QA Samples Shipped Via: Internal 07 55 Z Fed Ex Container UPS

'l Temp.:

Deg. C El Hand Custody Sealed?

qDate/Time DRel 2) l ived By Date/Time Custody Seal 1 8 ý-- h% (o C\ý1.E Other Intact?

ty-gelin-quished iy Date/Time 4) Received By Date/Time YO No Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time 790 1 Y/IZa6 571/

Health Physics Procedure GPP-GGGR-R5104-003-Attachmnent B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O0 1Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00372 00 0o 362 Injun Hollow Road, East Hampton, CT 06424 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones EC/ Cn Priority: Z 30 D. [] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Commen, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-01 OF 5/18/06 14:50 SE C BP x - x -Transferred from COC 2006-00364 9106-0002-011F 9106-0002-012F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 5/19/06 08:31 SE C BP x x 9106-0002-013F Transferred from COO 2006-00365 5/19/06 09:00 SE C BP X - X Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP X Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [ Radwaste QA El Non QA Samples Shipped Via: Internal S Fed Ex Container UPS Temp.:

Deg. C Q Hand Custody IýRelin ihe Date/Time 2) Redived By Datg/Time Sealed?

Custody Seal l . b-/,*)¢, .... I__ Other Intact?

3)"relinquished By Date/Time 4) Received By Date/Time BillofLading#YO NO

5) Relinquished By - Date/Time 6) Received By ""Date/Time 7qoQ Bill of Lading

"/Ii7/*j# i57ic?

Connecticut Yankee Statement of Work for Analytical Lab Services -CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received: (0 ~ t SDG#: 1;,. 0- 0 -- 46ý5 Work OrderNumber: __ C. '-2-0".

Shipping Container IDYIC t 4 6 5s1/ 9,/0 Chain of Custody# 4 ' - C# '2i/

1. Custody Seals ori shipping container intact?. Yes. No [ ]
2. Custody Seals dated and signed? Yes No [].
3. Chain-of-Custody record present? Yes No[
4. Cooler temperature _2 -
5. Vermiculite/packing materials is: Wet [ ] Dry [ f l] f "1
6. -Numberof samples in shipping container:
7. Sample.holding times exceeded? Yes [ No0'$/
8. Samples have:

-tape -hazard labels

_4-custody seals _____appropriate sample labels

9. Samples are.'

--) in good condition -leaking

-broken -have air bubbles

10. !Wereany anomalies identified in sample receipt? Yes ['] NoX]

11.I..Description ofanomalies (include sample numbers):

Sample. Custodian/Laboratory: K j

,' Date= (a J-"

Telephoned to: - On By ,

Page 9 of.:105

Connecticut Yankee Statement of Work for Analytical Lab Services 4 \ -Cy-IsCso-SOol0 Figure 1. Sample Check-in List Datefrime Received', *'0 ,a SDG#: )- -

Work Order Number: 1(.¢AZW 7' Shipping Codntainer ID1101 q N5 .S. W Chain of Custody#2vV (1 0 9.q

1. Custody Seals ori shipping container intact?. Yes No
2. Custody Seals dated and signed? Yes No[
3. Chain-of-Custody record present? Yes/J No []
4. Cooler temperature
5. Vermiculite/packing materials is: Wet [ Dry t, I 6.: Number of samples in shipping container: ..-
7. Sample holding times exc'eeded? Yes [ ]No.

.8. S I e.h have :

I. r~les S

-hazard

_tape labels custody seals -appropriate sample labels

9. Samples are-

.lngood condition .jeaking

.broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes fI No
11. .Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: t Lbf Date: 6 "o b Telephoned to: On0By Page 10 of:105  :.

SAMPLE RECEIPT & REVIEW FORM IClient:

Date Received:

Received By:

0IN-OR10' (1,cxinpQ4, 1 rju '(.a k e.SDG/ARCOC/WorkOrder:

PM use only PM(A) Review (ensre non-conforming items are resolved prior to signing);

Sample Receipt Criteria i CommentslQualifiers (Required For Non-Conforming Items) comainer I conainer other (describe) circle Applicable: seals broken damaged I Shipping containers received intact 7 and sealed? / dry ice none other describe)

Circle Coolant # ice bags blue ice Samples requiring cold 2 preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable:sdls broken damaged container leaking container other (describe) sealed? - "

5 Samples requiring chemical & p6 WD's. containers affected and observed pH:

preservation at proper pH? l I I

-VJ C A tn, . v , - A s ainm containers ariccted:

aaunpleu 6

r i (defined as < 6mm bubble)? *

= _ ,

=

I I1 Are Encore containers present?

I 7 (If yes, immediately deliver to VOA laboratorv'*

Smes received olding N's a - ts aIf- IeQ:

time?

ID's S 31113 c*ntainers affectie: I 9 Sample ID's ICOC match "IF 1-0ion bottles? j" Date &/me on COC match date Sample ID's affected:

I0

  • A---

& tirv6 on bottles? *I I 9-1 Ntber Of Containers received I ,

match number indicated on COC? J Sample ID'S affected:

mm 12 COC form is properly signed in C":L 2,00( +1 r

relinquished/received sections? I Air Bill Tracking #'s, &

14 Additional Comments

- h £ RSO RAD Receipt #

Suspected Hazard Information Z co *If> x2 area background is observed on samples identified as "nom-regulated/non-radioactive", contact the Radiation Safety group for further i

ARaologcalasictn al Classificaion? - . investigation.

A 1Ra Maximnum Counts Observed*: 4P B Comments:

lihipped as DO ITHazardou IdMaterial? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager. N#:

PM (or PMA) review of Hazard classiticatioll-V/

Page 11 of 105

-SSML RECEIPT & REVIEW FORM PM use only

[Client:onr!iu (cC' T" SDG/A RCOC/Work Ordler:_/.4Z Received:

vDate C, -jO, 0 pM(A) Review (I re non-cfnror gi are resolved prior to signing):

IlReceived By:

Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items)

Circle Applicable: seals broke damaged container leaking container other (describe) 1 Shipping containers received intact and sealed? /

71 ags blue ice dry ice none other describe)

Samples requiring cold Circle Coolant #

2 preservation within (4 +/- 2 C)? /

Record preservation method. /

Chain of custody documents included with shipment?

Sample containers intact and Circ pplicable: seals broken damaged container leaking container other (describe) sealed?

5 Samples requiring chemical Sample Is. containers affected and observed pH:

preservation at proper pH?

Sample ID's and containers affected:

6 VOA vials free of headspace (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) __.

Samples received within hold ini Id's and tests affected; time?

9 Sample ID's on COC matc: ID's Sample ID's and containers affected:

on bottles? ýK Date & time on COC tch date Sample ID's affected:

& time on bottles?

1Number of containee received Sample ID's affected:

I match number indic/ted on COG?

COC form is proldrly signed in 44--

12relinquished/recpived sections? Cc'C- Z.oO(s bp Air Bill ,Tracking #s, &

Additional Comments c eGJ Su U Hr ~RSO

  • If > RAD Receipt #___

x2 area background is observed on samples identified as "non-S regulated/non-radioactive", contact the Radiation Safety group for further rinvestigation.

A adiological Classification.?aximur Counts Observed:

[Shipped as DUI Hazardlu CB Regulated? ' t Comments:

cMaterial? If yes, contact Waste azard Class Shipped:

r Manager or ESH Manager. N#:

PM (or PMA) review of Hazard classitication: Initials- Date: 0-Page 2 of 05  !

Page 12 of 105 (J

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 ,

860-267-2556 +.~~~~~~

L ab 0,.,

Use O n ly * . . :

Project Name: Haddam Neck Decommissioning /C *'35 /  :. . . . . .

Analyses Requested Lab.Use"O..y Contact Name & Phone: ,Comments-.

Jack McCarthy 860-267-2556 Ext. 3024..

Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 .

843 556 8171. Attn. Cheryl Jones Cn' Priority: Z 30 D. [] 14 D. f 7 D. Container Sample Size- ..... .

Media Type &Type Comment, Preservation Lab I Sample Designation Date Time Code Code Code -o-mTransferred from C oC2006-00221 Sample 9106-0003-OOIF 4/24/06 14:13 SE C BP X i 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221 p$) 9106-0003-002F 9106-0003-003F 4/24/06 4/24/06 15:01 15:01 SE SE C C BP BP X X Transferred from COC2006-00221 Transferred from C0C2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 t 9106-0003-005F 4/25/06 09:21 SE C BP x Transferred from COC20O6-00223 .

9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223 9106-0003-007F 91I06-0003-008F 4/25/06 4/25/06 10:28 11 :15 SE SE C C BP BP - Transferred from COC2006-00223 Tr sf refomC 206 023 +". .

fi.... -.. ,. ":. ,  :"

NOTES: PO #: 002332 MSR #: 06-° SSWP# NA LTP U QA El Radwaste QA El Non QA Samples Shipped Via: .Inten Cifc.irier Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting. N Fed Ex  ! .:L.. D.eg C:

El UPS El Hand Custody 6! Sealedd?,

1)Relinquished By Date/Time 2),*ecpved By D Dat7 Time :CistodY Se adly at?

, "' " ', E, Other D.,:a. .

  • E. 7,,

N:"

3) Relinquished By Date/Time 4) Received By Dat e/Time _,_.. '__.__..__.

Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time .: 922-c*50-c 2 *.

Health Physicis Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00313 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested W My.

Contact N ame & Phone: '; ':

.....*e°ts.

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) .......

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <

843 556 8171. Attn. Cheryl Jones r 1 .

Priority: Z 30 D.El 14 D.[] 7 D. Sample Container Size-Media Type &Type amSample Desigation 9106-0003-009F Date Time Code Code Code Comment, Preservation  :"l* U .

4/25/06 13:00 SE C BP X Transferred from COC 2006-00236 0 9106-0003-010F 4/25/06 13:23 SE C BP X TransferredfromCOC2006-0026 , . .

SE C BP X Transferred from CO( 2006-00236 .

9106-0003-010FS 010* 9106-0003-012F 4/25/06 4/25/06 13:23 15:12 SE C BP X jTransferred from COC 2006-00236 0%1 9106-0003-013F 4/25/06 14:21 SE C BP x Transferred from COC 2006-00236 0j'L 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred fromCOC 2006-00236  ;'.' -

from COC 2006-00237 o6 9106-0003-015F 4/26/06 08:16 SE C BP X

- - -Transferred Transferred from COC 200--"0236 "...........

9106-0003-016F 4/26/06 09:41 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:9 SE IC BP X Transfered from COC 2-06-00237.  ;'

619106-0003-01 8F 4/26/06 08:59 SE IC _ BP x Transferred from COC 2006-00237 '

NOTES: PO #: 002332 MSR #: 06- or, S2- SSWP#NA Z LTP QA El Radwaste QA E] Non QA Samples Shipped Via:

[ Fed Ex ElUPS I] Hand

1) Relinquished By Date ime 2) eceived By at Time 2Stbd~4intact?

El Other

3) Relinquished By Date/Time 4) Received By Dafe/Time Bill of Lading 4 7k c2o-, 012,7- o0d t

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OO1 Figure 1. Sample Check-in List Date/Timne Received: 1t.ý/$,5/O(1 (016 SDG#: M..6&tI d. O I t,"Z- 3 .

Work Order Number:

Shipping Cdntainer ID: IG1 916 0 7-Cjl I Chain of Custody## O 63'%J"...

1. Custody Seals od shipping container intact?.- Yes [ ] No
2. Custody Seals dated and signed? Yes [ J.No .A '
3. Chain-of-Custody record present? Yes No[]

.4. Cooler temperature .) C]

5. Vermiculite/packing materials is: Wet [ Dry[ // '-
6. Number of samples in shipping container: [ W /

. []DI .] C' 7- Sample holding times exceeded? Yes [ No

.8. Sampl ,...

- tape -hazard labels

_Z custody Seals -appropriate sample labels

9. Samples are:

good condition . '*Ieaking

-__broken . " have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ ] No
11. .Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:_ (L C) ( ("ecf. c, Datez. "/7 2 ' "

Telephoned to: On By.

Page 15 of 105

'I

0 SAMPLE RECEIPT & REVIEW FORM r

I'Mme only i a2 1335r Date, Received: 14M(A) R (eusure non-co items a resolved prior to signing):

Received By: C (, J Ca Sample Receipt Criteria Z Z Comments/Qualiriers (Required for Non-Conforming Items)

IShipping containers received intact Circle Applicable: seals broken datmaged container leaking container odr (descrilx)

'and sealed? -- , _

Samples requiring cold Circle Coolant # ice bags blue ice dry icc none 2 preservation within (4 +/- 2 C)?

IRe__dreservation method. / P e &toit-Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable: seal broken damaged container leaking container oaher(describe) sealed?

Samples requiring chemical Sample ID's. containers affected and observed pH:

reservation at proper pH?

VOA vials free of headspace Sample ID's and containers affected:

(defined as < 6rm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) .... __

Samples received within holding Id's and tests affected:

time?

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottles?

Date & time on COC match date Sample ID's affected:

& time on bottles?

Sample ID's affected:

Number of containers received match number indicated on COC?

COC form is properly signed in relinquished/received sections? _ _.._ _ __ _

14 Air Bill ,Tracking #'s, & '-- q .d C Additional Comments I It OV-a V RSO RAD Receipt#

Suspected Hazard Information *If > x2 area background is observed on samples identified as "non-St w regulated/non-radioactive", contact the Radiation Safety group for further

__ 9 investigation.

A 1Rad* gical Classification? Maximum Counts Observed*:

i TPCH Regulated Comments:

Shipped as DOI Hazardous Ci Material? If yes, contact Waste Hazard Class Shipped:

Manager or ESH Manager.1 UN#:

PM (or PMA) review of Hazard classification: Initials L 16 , Date: 0(,

01 1 Page 16 of 105 (/

I I,

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O() 1 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 I

ýProject Name: Haddam Neck Decommissic

Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: 0 30 D.[] 14 D. [] 7 D.

Samples Shipped Via:

9 Fed Ex Dl uPs nl Hand El Other Bill of Lading #

Health Physs Prbedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major "C~ut~tYankee Atomic Power Company I-. '6jun Hollow Road, East Hampton, CT 06424 860-267-2556

)jectName: Haddam Neck Decommissioning Contact Name & Phone:

Jack McCarthy-' 860-267-2556 Ext. 3024 Analytica! Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z 30 D. [] 14 D. F] 7 D.

Samples Shipped Via:

[ Fed Ex E UPS

[] Hand LI Other Bill of Lading 4

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/l'imc Rcceived: .I- /,. 0 G SDG#: /X, R L',,- o, F4 Work Order Number: /- *3 2 '/

Shipping Container ID: "qjq 335- 8812 Chain of Custody # 0 1 - 6 O,.7 -I aoo 1.. Custody Seals on shipping container intact? Yes No [ ]

2. Custody Seals dated and signed? Yes No []
3. Chain-of-Custody record present? Yes No [3
4. Cooler temperature
5. Venniculite/packing materials is: Wet g Dry [
6. Number of samples in shipping container:
7. Sample holding times exceeded? Ycs [I No
8. Samples have:

-I'_tape -hazard labels

_t custody seals appropriate sample labels

9. Samples are:

_ in good condition _ 4 -_leaking broken have air bubbles

10. Were any anomalies identified in sample receipt? Yes No [3
11. Description of anomalies (include sample numbers):

Sample Custodian/Laboratory: Zýýt Date: /.?.I (I. 'a..po I - w-Telephoned to: On -BY-__

Page 45 of 56 Page 19 of 105

" Connecticut Yankee Statemnt of Work for Anab*ical Lab Services CY-ISC-SOW.O0 Figure 1. Sample Check-in List .

Dawne erecxivc O2X SDG# .JOG4 Work OrderNumber. Ivt .-*I_"

SShipping C"tainer w &,.- Chain of Cu AF)Oo".

  • .CsoySasaihwppng container intact?. Ye[No$
2. CustoSeals dated and signed? Yes-[ jNof
3. Chiof-CUsty recordPresent?, Ycs N
4. Cool. wiperataw S. arnicu~ite/P3Cjd~g rnaezials -is: 'Wet

~Dlyt\

7 -Sa le holding td " . Y.s[."oU

8. Sampleshae

-A~4custody se Appropzate sample labels

9. Samples arm:

.ngood cozlition 2Jein

.-....... . ...: -L.*..hve air bubbles

10. Werem ny eoinfl . YeS*.

Yes N'o'-

D  ; ta" *" " 's(1qud " "be*)

S~ampCsdvjp~.(,v ,

  • ,.c ,o._______...

__________O Page 20 of 105

' I1t,

8 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM

-AZ qqF~gf)- (DID?)?) A_m1~ _ _ _ _ Se.i

-pe (D o 0..,*  :)k (- . ,0

- -h" (Qnl ro( - 00330 C(o")

biq. g CL rro 3~5n\xo(> ~r b.s- c*. -a 1C6C2

\__ _

  • :*_e,.* cGO ) ,4.pS J'

Page 21 of 105 I III

SAMPLE RECEIPT & REVIEW FORM PM use only Client: CO- Y A-11-.- .- SDGIARCOC/Work Order: 1/( T93Z-Date Received: C - jPM(A)

F, Review (ensire fon-coniorming items are resolved prior to signing)-

eceived BY: l_____________ _____

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items) 1 Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) 1and sealed? - I Samples requiring cold Circle Coolant # ice bags blue ice dry ice ROMe other decribe) 2 preservation within (4 + /- 2 C)?

Record preservation method.--_ _ _-_--

Chain of custody documents included with shipment? C cnee seals broken damaged container I n other(descr SSample containers intact and A Ap @lop-ooo.1k. ll.

sealed?

Samples requiring chemical "" mpte is. eontaine-, affected and observed pH:

Srervation at proper pH?

6 VOA vials free of headspace (defined as < 6mm bubble)?___

Sample ID's and containers affected:

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) __,

Samples received within holding Id's and test affected:

8 time? __,

Sample ID's on COC match ID's 1Sape IDys and comaineM affected:

on bottles? ,

&time& time on COC match date 10 Date Sam affected:

'ID' on bottles? __._,,

Number of containers received Sam* 1 e'satcted:

1match number indicated on COC?

COC form is properly signed in relinquished/received sections? 1 x._( oc. i0 r , ,

Air Bill ,Tracking #'s, &

14 Additional Comments

~~~ ORADkReceipt# __________

o *If > x2 area background is observed on samples identified as . 'n-Suspectedd. -. nnregulated/non-radioactive', contact the Radiation Safety group forfturther A Radipoioca C*

  • sicv-0n.n.

-u' 'J~s: ~.MI -

i PUB Regulatedl?

b ,

omments:

MMYC -

I - pped as. I Hzardous .

C Material? If yes, contact Waste lazard Claw Shipped: /*

"Manager or ESH Manager. Y rPi099t!ýfr ~yj'.w of Hazard classification: Initials Date: 7-h 7/-Z

SAMPLE RECEIPT & REVIEW FORM PhM 0 only Client:

Date Received:.

Received By:

vrnb~b c '

~SDG/ARCOCIWorJi PM(A) Rev Orde; lew 2

/67-r97-2,j 2 frl r_..

IS wre resolved piow to sigaing):

1 Sample Receipt Criteria >0 z Z Comments/Qualfimrs (Required for NouuConforming Items) conmain odher (describe)

Circle Applicable: seals broken damaged container leaking 1 Shipping containers received intact and sealed? Circle Coolant _ icebags _ blueice _ dryicedescribe)

Samples requiring cold Circle COi I ie bags blue --e dry ie dr dcr) 2 preservation within (4 +/- 2 C)?

-Record preservation method. -

Chain of custody documents C..O*> c~gi, w tA-included with shipment? . ..... " t V-SSample containers intact and ic~l~1PiC-k biC5Cuclsbf en damaged container Icaking continerk oadcrit  :

sealed? I.ampte I VO \t. -1117 qrn Samples requiring chemical Sample IDa. containers affected and observed pH:

preservation at proper pH? ........ .

VOA vials free of headspace Samle ID's and colainein affected:

6 (defined as < 6mm bubble)?._._..=

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)__

Samples received within holding Ida's and tests affected:

time?

Sample ID's on COC match ID's San ID's ad conainers affeted:

9 on bottles?

Date & time on COC match date Sample to's affected:

10

& time on bottles?

Sml DS2lCd 11Number of containers received match number indicated on COC?

COC form is properly signed in Yfl CbC. "Y't, vl-U*cl ri 11 relinquished/received sections?

14 Additional Air BIl ,Trcking #'s, &

Comments SU 1 ~ - c Stt-SRSO RADRecipt_#

A -f > x2 areabackground is observed on samples identified as *non-Suspected Hazard Information Z regulated/non-radioactve'. contact the Radiation Safety group for firther tavc We investigation.

RAdiological Classification? Maximum Counts Observed*:

rinpped as VtO Hazardous Material? If yes, contact Waste V, Hazard Class Shipped:

i UN//:

Jmanager or ESH Manager.

PM (or PMA) review of Hazard classification: Initials Date: .

U Vj

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 iect Name: Haddam Neck Decommissionina I Contact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: M 30 D. [] 14 D. El 7 D.

Samples Shipped Via:

[ Fed Ex UPS E' Hand El Other Bill of Lading #

7qzi- ?9I9

. .,C on n ecticut Yan kee -CY -isc-SO W- 1O0 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List.

Date/Time Receiv :_ 4' 0 3*

SDG#

W ork Order Number:

I. .. .03 Chain of Custody# _Ig 0c 9 Shipping Co'ntainer ID" J%!,

Y es No ]

- C. ustody Seals oii shipping container intact? _

Y es' ..No []

2. C ustody Seals dated and signed? .

Yes J4 No I ]

3. Chain-of-Custody record prýsent?

.If I,, "

.4. Cooler t-mperature Wet W.'Dry J%.

5. Vermiculite/packing materials is:

6.' .Number ofsamples in shipping container:..

Yes

" o ]N

7. Sam ple holding times exceeded? .

.8. Samples have:

tape htazard labels*J

-. _*custody seals - appropriate sample labels 9.Samples are:

j__n good condition -Zleaking(vte- )

-broken -' have air bubbles Yes []No [4'

10. Were any anomalies identified in sarnple receipt?

.Description of anomalies (include sample numbers):

  • 1..

p e

  • an , b or to

.va tTeeph o:__

to*_ _ __ _ _

-Page 25 of 105.

SAMPLE RECEIPT & REVIEW FORM PM use only Client: 1SDG/ARCOC/Work I Order: IG Z-85 Date Received: PM(A) Review JL (ensure ao-confo items are resolved prior to signing):

Received By: (f r 14 K Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) a"ksealed?

Circle Coolant # blue ice dry ice none other describe)

Samp requiring cold ice bags 2 preservati within (4 +/- 2 C)?

.RecorTd preserv on method. __________________________

Chain of custody d nts 3-included with shi ment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed? .. ...

5 Samples requiring chemicalSample ID's. conainers affected and obeved pH:

,preservation at proper pH?

6VOA vials free of headspace Sample ID's and containers affected:

6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) AI 8 Samples received within holding Id's and tests affected:

time?

9oSample ID's on COC match ID's Sample ID's and containers affected:

Sample 11D's affected:" . ...

10Date & time on COC match date 1 & time on bottles?

Number of containers received Sample ID's affected:

match number indicated on COC?

COC form is properly signed in 12 relinquished/received sections?

14 Air Bill ,Tracking #'s, & -i * [ " g'" ]7 ..

Additional Comments '*1 8 - [*'°>

PC I

V RSO RAD Receipt #_____ _______

i S *gf > x2 area background is observed on samples identified as "non-Suspected uazaru Informnation zZ--

  • -[ regulated/non-radioactive", contact the Radiation Safety group for further W F investigation.

SlRadiological Classification? 7 Maximum Counts Observed*:

PCB Regulated? Comnments:

Shipped as Dt tHazardous [Hazrd Class Shipped:

C Material? If yes, contact Waste HzrCs Manager or ESH Manager.

PM (or PMA) review of Hazard classification: Iniials C Date: 77 ""

-- a--* V........I G/

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-0O 1 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424

.860-267-2556 iroject Name: Jladl0am NecJK tecommissic

  • ontact Name & Phone:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z 30 D. Ml 14 D. M] 7 D.

Samples Shipped Via:

[ Fed Ex El UPS El Hand

[] Other

_7Bill of Lading #

o.970 17-00 f-

Connecticut Yankee Statement of Work for Analytical Lab Services -CY-Isc-.Sow-o0l Figure 1. -Sample Check-in List Date/lime Received =

AX 5 (0 Work Order N um ber _/.-_ _ _--_ _.

Shipping Cdhtainer ID: C0*:t

((Qt, 1 5 N2(t Chain of Custody# "E i (O*:idý s-'--

1. Custody Seals. onshipping container intact?.. -Yes.[ ]No*4
2. Custody Seals dated and signed?

Yes[j I No

3. Chain-of-Custody record present?

Yes.No CI]

A. Cooler ..emperatu..e

5. Vermiculite/packing mateials-is:

Wet F Dry ', J 6.' Number ofsamples in shipping containr (-pf.

7. Sample holding Limes Cxceeded? . Yes [Not4)

.8.. Samples have:

.J~tapehazard labels

-- t-usoyseals -appropriate sample labels

9. Samples ae:-

in gX Rood condition leaking

- broken -" have air bubbles

10. Were any anomaliesidentified in samp.! recipt?

Yes No II.. Description of anomalies (include sample numbers):

Sa* l C .*yus todi.,,/L b t -_ a DIate - -.

Telepphoned tO:

  • 0 Page 28 of 105

.'I 11ý

/ SAMPLE RECEIPT & REVIEW FORM O4*4tOR** *I'm me eoly Client: .. nO-, JSDG/ARCOC/Work Order: ( szr8-, /6,Z",,

Date Received: =5- i(A) Revilew (esre noo-conor mifn ItoElUwe resolved priorto signing):

P".

Received By: C t-wi ~k. k i ~ A Sample Receipt Criteria Comments/Quamliners (Required otr Non-Conforming Items)

Shipping containers received intact Circle Applicabl: seals broken damaged cominer leaking container other (describe) and sealed? AM7_

Samples requiring cold Ci-cle coolant # ice bags blue ice dry ice Qn) other demrf) 2 preservation within (4 +1- 2 C)?

Record preservation method. - C_

Chain of custody documents CO Us ca( 6 V CA-included with shipment? ,

Sample containers intact and ;in;kA~picabtW; sdizubr= damged container leaking container (odxw (describe)

CR-Ctig i11qm q4% ,_

sealed?

Samples requiring chemical ID's. comainc- affected and obsmd pH: .

preservation at proper pH?

VOA vials free of headspace Samle ID's and contaiaers affected:

6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) .. ....

ld'3 and t afece:

9 Samples received within holding time?

SSample ID's on COC match ID's Sample ID's and cowaies affected:

on bottles?

Sample ID's affected:

10Date & time on COC match date

& time on bottles?

Number of containers received ,Upl ID's affected:

match number indicated on COC?

COC form is properly signed in t CbC,3 Cit. YWrVIt svkt d einuished/received sections? __________________________

Air Bill ,Tracking #'s, & %et osrt )tmuOd,-t l*ke-i Additional Comments

  • '11 RSO RAD Receipt I Suspected Hazard Information e -If > x2 am backgroun is observed on samples identified a3 *non-Za ~ regulated/non-radioaczive. contact the Radiation Safety group for further

_ __* investigation.

  • Radiological Classification? Maximum Counts Observed*: t .,C B lPC Regulaie? Comments:

Hazardous

[Shipped as DO)I c fMaterial? If yes, contact Waste / Hazard Class Shipped:

NManager or ESH Manager. UN:

PM (or PMA) review of Hazard classification: Iniials Date: , o rageL _ of 1U5 V

SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM

,4A~ 167- 932 J&Z85

_____ 7,

_____ q\ uw?)3O C9WC)t) *Leq

____ A 00K'o - 00 S ) (0033) .

(a105 doý'W-A% 0,0 53? VP f(A)5 c~cIýlev h a.d m ~ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

busf

  • td 0G*_

3CLM Page 30 of 105

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major ConneticutChain of Custody Form No. 2006-00367 (bQ Connecticut Yankee Atomic Power Company CD 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 / 3-7 f_ __

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only A

Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 o 843 556 8171. Atta. Cheryl Jones Ln I, Container Priority: [0 30 D.[] 14 D. El 7 D.

Sample Size-Mcdia Type &Type Sample Designation Date Time code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X XX Transferred from COC #2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-OOSF 5/5/06 14:17 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C X xBP Transferred from COC #2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP X X X Transferred from COC # 2006-00325 NOTES: PO #: 002332 MSR#: 06- -/3 SSWP#NA SLTP QA El Radwaste QA E] Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: _ Deg. C El UPS Dl Hand Custody Sealed?

I I. / YO NO

1) elinqu.s*he Date/Time 2) e ivId = Ie Time Custody Seal Intact?

El Other

3) Winquished By Date/Time 4) Reaeive y v late/Time YO No Bill of Lading #

Health Physics Procedure GPP-GGGR-R5 104-003-Attachmnent B-CY-001I Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major

~Chain of Custody Form CD Connecticut Yankee ~No. Atomic Power Company 2006-00366 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 .,._ __ . .. I.

0 -

Project Name: Haddamn Neck Decommissioning -

Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ,

843 556 817 1. Atta. Cheryl Jones z Priority: Z 30 D. [] 14 D.'[-]7 D, Container Sample Size--

Media Type &Type Sample Designation Date Time Code Code Code ""

Comment Preservation Lab Sample ID p 9106-0008-008F 5/08/06 08:01 SE C BP X x x Transferred from COC # 2006-00327 010 9106-0008-009F 5/08/06 08:32 SE C BP X x x Transferred from COC # 2006-00327 oil 9106-0008-01OF 5/08/06 09:09 SE C BP X x x Transferred from COC #2006-00327 01 9106-0008-01OFS 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 1 9106-0008-01IF 5/08/06 09:30 SE C BP x X X Tranferred from COC #2006-00327 I0* 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC N2006-00327 514 9106-0008-013F 5/08/06 10:16 SE C BP X X X Transferred from COC #2006-00327 9106-0008-014F 5/08/06 10:47 SE C BP X X X Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA SLTP QA Dl Radwaste QA 0l Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: "ZJ Deg. C F1 UPS Dl Hand Custody Sealed?

YO N)T

1) Relinquished By Date/Time 2) Received By Date/Time Custody Seal Intact?

~t,._Q , El Other Rlinuishd I'0Q1A4,Itelh) 4 Recive By

3) Relinquished 3)

B Dat/Tie atetiI By Date/Time 14) Received By Date/Time Y97 NO Bill of Lading #

Statement of Work for Analytical Lab Services -CY-ISC-SOW-001 Figure 1. Sample Check-in List.

Date/rime Received: _abYLIoto SDG#:

Work Order Number:____

Shipping Cdhtainer ID:0_ ¢'" l, Chain of Custody # 33--04f 0 0.C

1. Custody Seals on'shipping container intact?.. -Yes ['rT o [I
2. Custody Seals dated and signed? Yes [j No [-
3. Chain-of-Custody record present? Yes [-"o [1.

.4. Cooler temperature

5. Vermiculite/packing materials is: - Wet [ . Dry -, ] /A 6, "Number of samples in shipping container: " "
7. Sample holding times exceeded? Yes [ ] No
8. Samples have:

_____hazard labels

-. custody seals /_appropriate sample labels

9. Samples are:

. _ in good condition _ leaking

-broken -have air bubbles

10. Were any antomalies identified in sample receipt? Yes ' ] No

-11.....Description ofanomalies. (include sample numbers):

Telephoned to:__ 0n _ "______"

On .' By.*. -.-

Page 33 of 105

~~SAI4LE RECEIPT & REVIEW FORM CCW

)C9 4,,

PM meqoMB S DG/ARCOC/War Order: -b V.

Ree (d s o m-me4e- e; a rereso,, e-prior to ds l u) :

gm

.( qf .t)i R elv y .- - -I Sample Receipt Criteria ~CommenbtQuailfles (Required for Non-Confo=nlf Item)

Shipping containers received intact / A d

.... cc=...- le-k-- .,--au. ._*_ (,ac._,)

and sealed? /"*

cle CooCa 0 ice h*agp b.ue ice dry keo d---

Samples requiring cold 2 preservation within (4 +/- 2 Q?

Record preservation method. "

3Chain of custody documents inchlded with shipment? _ _,_,_,

iaro sis ken ddaim edmag Cofit W ina contaer d"-- (dcib)

Sample containers intact and 4 sealed? _____________________

Samples requiring chemical / WD's. cImiueM affemed and observed pH:

preservation at proper PH? ,_,

VOA vials free of headspace /pl: D's d m m'ct.

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes. immediately deliver to VOA laboratory)

Samples received within holding time?

/d's and mafted:

D's on COC match ID's SSampli ID's sed cmieflets affecte:

on bottles?

muvi I'S afcd:

Dat & time on COC match date

& time on bottles?

Number of containers received /f'aew:

match number indicated on COC?

COC form is properly signed in relinquished/received sections?

Air Bill ,Tracking #'s, &

.Addition

.1111111=3 f5 4 r Suspeced Hazard information d1" j SO.~jIRSO f > RAD

-~I x2 ameRecipt I backgrond regulated"/non-radioactive",

is observed on samiples identified as !11W-contact the Radiation Safety group for fur ad- linvestigadon.

I-71 ~.---~ 4I j% a - n.m ass on, Vi lql I ConsOsre*: Che1 0*fL7 -g 0 B

lIhanaerasor1 _HMazarders lazard Class Shipped:

CiMaterial?: if yes, contact Waste IManager or ESH Manager.. JHI:

PM (or PHfA) review of Hazard classification: Initials RA!Z ./40/- Date:

I-Page 34 of 105

j SAMPLE RECEIPT & REVIEW FORM 107

'el1011it PM uase Gal7 CClient:

Date Received:

Yanke&

,PM(A)

SDG/ARCOC/Work Order: I37Tl '/.

Review (ensure so,-.ronr,,g it.- -- r',lve prior tosgin" fReceived By: C_. I A' r"h', _ __ _ _ _ __-

Sample Receipt Criteria Z Comments/Qualifirs (Required for Non-Conforming Items)

Shipping containers received intact Cirde Applicable: seals broken damaged container leaking container other (describe) 1 and sealed?

Samples requiring cold Circle COolat # ice bags blue ice dry ice i5 odwer describe) 2 preservation within (4 +/- 2 C)?

Record preservation method.

3 Chain of custody documents 4-included with shipment?

Sample containers intact and- 1 Circle Applicable: seals broken damaged container leaking container odter (describe) sealed?

5 Samples requiring chemical Sample ID's. containers affected and observed pH:

- preservation at proper pH? _"

Satmle- ID's and containers affected:

6 VOA vials free of headspace (defined

( as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to /

VOA laboratory) tsd and tseat affected.

8iSamples received within holding time? _____________________________

9 Sample ID's on COG match ID's S,,arple ID's and comntners affected:

on bottles? --.-

Sample ID's affected:

10 Date & time on COC match date

& time on bottles?

Number of containers received Sample ID's affected:

1 match number indicated on COC?

I COC form is properly signed in

  • o 4 - l,-., aflqL. I 2 relinquished/received sections?

ILace t "1 2"* 't.-f 14 Air Bill ,Tracking F's, &

Additional Comnents Suspected Hazard Information Is

v RSO RAD Receipt #

  • if > x2 area background is observed on samples identified as 'non-Oh I GSJ regulated/non-radioactive', contact the Radiation Safety group for further investigation.

-~ -........-. '-

Li A I Radiological Classitacation9 vI ounts Observed*:' 40 f.P-t- I B PCB Regulated?

Shipped as DOI Hazardous Hazard Class Shipped:

Material? If yes, contact Waste UN#:

Manager or ESH Manager.

PM (or PMA) review of Hazard classification: 'j Initials , Date:

I Page35 of 105

I (oB-7qI V, Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List DaterTime Received: 57/ IkeI Tt@O' "3 SDG#:

Work Order Number:

Shipping Cdntainer ID: 1qe2 104 i1113 Chain of Custody# e* .S?3ip " La-.,

1. Custody Seals ori shipping container intact?.. *Yes j o [I
2. Custody Seals dated and signed? Yes Lý1o [ ]-
3. Chaia-of-Custody record present? Yes L-9o [I
4. Cooler temperature
  • 2/ .
5. Vermiculite/packing materials is: Wet Vr* ry 1`1]
6. -- Number of samples in shipping container: "tj h-hk
7. Sample holding times exceeded? Yes- [ No
8. Samples have:

-" tape hazard labels custody seals appropriate sample labels

9. Samples are-

-,.-ingood condition leaking broken ____have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ I No
11. )Description of anomalies (include sample numbers):. A* A

/

Sample. Custodian/Laboratory: el cz; Datez 5/?-(illl*

Telephoned to: On By Page 36 ofl105 1~1

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major

/& 45401 -/.

Chain of Custody Form No. 2006-00380 0*

Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabkUse. Only, t Contact Name & Phone: C6mments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 0 < ,

843 556 8171. Attn. Cheryl Jones C/)

Priority: Z 30 D. D] 14 D. E] 7 D.

Sample Container Size-Media Type &Type .

Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID

  • l-9106-0009-016F 5/15/06 13:28 SE C BP x X Transferred from COC 2006-00352

,19106-0009-016FS 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-011F 5/15/06 14:03 SE C BP X Transferred from COC 2006-00351 9106-0009-013F 5/15/06 08:35 SE C BP x X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 D17 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 6i1 9106-0009-015F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 9106000-01F 0936 515/6 E C BP X TrnsferedromOC206-035 NOTES: PO #: 002332 MSR #: 06-Og1f SSWP#NA E LTP QA 0 Radwaste QA El Non QA Samples Shipped Via: Internal Container 2 Fed Ex Temp.: ___ Deg. C LI UPS F1 Hand Custody Sealed?

YO NO]

1)Relinquis;d By Date/Time 2) Rec d y Date/Time Custody Seal Intact?

El Other

3) Relinquished By Date/Time 4) Re eivek By Date/Time YFt N !

Bill of Lading #

Ft

Health Physics Procedure

/1'zJ W-1 GPP-GGGR-R5104-003 -Attachment B-CY-001 Major

~Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00381 0CD ~860-267-2556 362 Injun Hollow Road, East Hampton, CT 06424 0

Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only DContact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories n 2040 Savage Road. Charleston SC. 29407 0?

843 556 8171. Attn. Cheryl Jones W z Priority: Z 30 D.[] 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 01 ýt 9106-0009-OOIF 5/11/06 13:22 SE C BP X X Transferred from COC 2006-00347

[ 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 01 9106-0009-003F 5/11/06 14:06 SE C BP x x Transferred from COC 2006-00347

( 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 0 IA 9106-0009-005F 5/11/06 14:55 SE C BP x X Transferred from COC 2006-00347 01 " 9106-0009-007F 5/12/06 07:44 SE C Bp X X Transferred from COC 2006-00348 04* 9106-0009-008F 5/12/06 08:16 SE C BP x x Transferred from COC 2006-00348

( 9106-0009-009F 5/12/06 08:35 SE C BP x x Transferred from COC 2006-00348 01

'! 9106-0009-OIOF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 61 NOTES: PO #: 002332 MSR # SSWP# NA [9 LTP QA 77 Radwaste QA E] Non QA Samples Shipped Via: Internal Container

[ Fed Ex Temp.: _ Deg. C Tips El Hand Custody Sealed?

YE] NO

1) Relinquished By Date/Time 2) Rece edy Date/Time Custody Seal Intact?

Sr Azq6111: 460 L El Other

3) Relinquished By Date/Time 4) Receivedby Date/Time YO ND Bill of Lading #

/q tl /y/ I-VIT

. ILI) i~~~45~IZ Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-sOw-o00 Figure 1. Sample Check-in List Date/Time Received:- 1 - U6-0 SDG#:_ __ _

__.___ S

_____ _ ~. o'~e~<

Work Order Number:

Shipping Cdntainer ID: 1.', lift Chain of Custody #

1. Custody Seals oxi shipping container intact?. Yes -- No [ ]
2. Custody Seals dated and signed? Yesj ].No.o
3. Chain-of-Custody record present? Yes No t
4. Cooler temperature 0 ,
5. Vermiculite/packing materials is: Wet [ Dry*

61 Number of samples in shipping container:

7. Sample holding times exceeded? Yes [D No [ 1

.8. Samples have:

)tape _____hazard labels

&- custody seals -appropriate sample labels

9. Samples are'

-A-in good condition -leaking

-broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes[ ] No
11. *..Description ofanomalies (include sample numbers):

Sample Custodia/UIbboratory: Date: _,-- -t L:c2 Telephoned to: On By II, Page 39 of 105

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 1 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 c Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ,

843 556 8171. Attn. Cheryl Jones U) CIr C.0 "z Priority: Z 30 D. Fl 14 D. [17 D. Sample Container size- /*,1*. /

Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID p 9106-0010-OO1F 5/04/06 10:49 SE C BP X X Transferred from COC 2006"00321 0i0 9106-0010-002F 5/04/06 11:12 SE C BP X x Transferred from COC 2006-00321 oit 9106-0010-004F 5/04/06 12:48 SE C BP x X Transferred from COC 2006-00321 9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321 Iat 9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 o9 9106-0010-OIOF 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 01a 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 9E--106-0010-013F 5/04/06 15:06 SE C BP x Transferred from COC 2006-00321

,nt,,a Cntane NOTES: PO #: 002332 MSR#: 06- 0707 SSWP#NA Z LTP QA [I Radwaste QA Dl Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: /17Deg. C E ups El Hand CustodySealed?

Y9" NO3 1)RelinquishedBy DateT' e 2) Received By Date/Time Custody Seal Intact?

El Other 3)Relinquished By Dateftime 4) Recelived By Date/Time Y 9-"N D Bill of Lading #

~3ý4o- 3)U-9ý

Connecticut Yankee Statement of Work for Analytical Lab Services CY-lsc-Sow.-0l1 Figure 1. Sample Check-in List C

.Al1C . . I DateiTime Received: 67 . 1 /. 0 b SDG#:- 7 . &A-07/ -7 Work Order Number:__ ,*.k0.'

Shipping Ccfntainer ID: -7'0 31gi? 85s yl Chain of Custody # ' " 39

1. Custody Seals ori shipping container intac t? Yes .INo [ ]
2. Custody Seals dated and signed? Yes [' No [I1.
3. Chain-of-Custody record present? Yes [4 No

.4. Cooler temperature (7 'C

5. Vermiculite/packing materials is: Wet Dry Li
6. Number of samples in shipping container:
7. Sample holding times exceeded? Yes [ ] No i,

.8. Samples have:'

._tape -hazard labels

...... custody seals appropriate sample labels AAIL

9. Samples arei

._ in good condition . . leaking

-broken -- have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ No I ._ -.Description of anomalies (include sample numbers):

Sample Custodian/taboratory: Date: ,-o0 Telephoned to: "-n0O- By Page 41 of 105 11,M

q'-ENG/AV 4

SAMPLE RECEIPT & REVIEW FORM 0 IhM use only Client: (~g/SDG/ARCOCIWork-Order:

Date Received: S- [ "7 PM(A) Review g itens are resolved prior to signing):

Received By: A4- 4 I Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conrorning Items)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) and sealed? I Circlc Coolant # ice bags blue ice dry ice 4 other describe)

Samples requiring cold 2 preservation within (4 +/- 2 C)?

Record preservation method.

Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (desc'ibc) sealed?

~Sampies requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH?

Sample ID's and containers affected:

6 VOA vials free of headspace 6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id's and tests affected:

time?

9 Sample ID's on COC match ID's Sample ID's and containers affected:

on bottlesS 10 Date & time on COC match date Sample I's affected:

& time on bottles? V Number of containers received Sample ID's affected:

match number indicated on COC?

12 COC form is properly signed in 2 relinquished/received sections?

Air Bill ,Tracking #'s, &

Additional Comments

' v* - RSO RAD Receipt #

_5 -if > x2 area background is observed on samples identified as "non-Suspected Hazard Information 0 regulated/non-radioactive", contact the Radiation Safety group for further

_X 9 investigation.

A IRadiological Classification? 1 - Maximum Counts Observed*:

B IPCB Regulated? V omns Shipped as D iTHazardous I C Material? If yes, contact Waste Hazard Class Shipped:

UN#:

Manager or ESH Manager.

PM (or PMA) review of Hazard classification: Initials Date: /,,

.1 /

Page 42 of 105

List of current GEL Certifications as of 15 August 2006 7171.. State Certification Alaska UST-062 Arizona AZ0668

- Arkansas 88-0651 CLIA 42D0904046 K California 0115ICA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Idaho N/A Illinois 200029 Indiana C-SC-0 I Kansas E-10332 Kentucky 90129 Maryland 270 Massachusetts M-S COI12 Michigan 9903 Nevada SC002 New Jersey New York- 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 68-485 Pennsylvania South Carolina i 10 120001/10585001/10120002 Tennessee .. . 02934 .

Texas TX213-2006A U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington . ...

.... C223 .. .. . . . .

Page 43 of 105

RADIOLOGICAL ANALYSIS Page 44 of 105

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555696 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153129 Method Blank (MB) 1201153130 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153131 168340011(9304-01-005C) Matrix Spike (MS) 1201153132 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.

Page 45 of 105

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Page 46 of 105

Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 557837 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404009 9106-0006-005F 168404010 9106-0008-006F 1201158316 Method Blank (MB) 1201158317 168404009(9106-0006-005F) Sample Duplicate (DUP) 1201158318 168404009(9106-0006-005F) Matrix Spike (MS) 1201158319 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105

All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555697 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 48 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153133 Method Blank (MB) 1201153134 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153135 168340011 (9304-01-005C) Matrix Spike (MS) 1201153136 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 49 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555698 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 50 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-011 F 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153137 Method Blank (MB) 1201153138 168340011(9304-01-005C) Sample Duplicate (DUP)

.1201153139 168340011(9304-01-005C) Matrix Spike (MS) 1201153140 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Page 51 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105

Sample ID Client ID 168404003 9106-0003-004F 168404004 9106-0003-015F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201154644 Method Blank (MB) 1201154645 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201154646 168404003(9106-0003-004F) Matrix Spike (MS) 1201154647 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F),

1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150561 Method Blank (MB) 1201150562 168340012(9304-02-003C) Sample Duplicate (DUP) 1201150563 168340012(9304-02-003C) Matrix Spike (MS) 1201150564 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 55 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555722 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 56 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153222 Method Blank (MB) 1201153223 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153224 168340012(9304-02-003C) Matrix Spike (MS) 1201153225 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Page 57 of 105

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555723 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 58 of 105

Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 1201153226 Method Blank (MB) 1201153227 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153228 168340012(9304-02-003C) Matrix Spike (MS) 1201153229 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Page 59 of 105

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 554582 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201150569 Method Blank (MB) 1201150570 168340011(9304-01-005C) Sample Duplicate (DUP) 1201150571 168340011(9304-01-005C) Matrix Spike (MS) 1201150572 Laboratory Control Sample (LCS)

Page 60 of 105

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Page 61 of 105

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 554583 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150573 Method Blank (MB) 1201150574 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201150575 168404003(9106-0003-004F) Matrix Spike (MS) 1201150576 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Page 62 of 105

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

Page 63 of 105

The following data validator verified the information presented in this case narrative:

Reviewer/Date: W &&§e-'- ý'q.

Page 64 of 105

SAMPLE DATA

SUMMARY

Page 65 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 66 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Proiect: YANK01204 Sample ID: 168404001 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0 +/-0.102 0.00 +/-0.102 0.0956 pCi/g BXLI 08/11/06 1336 555696 1 Curium-242 U +/-0.0995 0.00 +/-0.0995 0.138 pCi/g Curium-243/244 U -0.C +/-0.0717 0.0405 +/-0.0717 0.177 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.199 +/-0.228 0.181 +/-0.229 0.444 pCi/g BXL1 08/11/06 1633 555697 2 Plutonium-239/240 U 0..0341 +/-0.129 0.120 +/-0.129 0.323 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.0 +/-6.64 5.08 +/-6.72 10.7 pCi/g BXLI 08/16/06 1220 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 +/-6.67 5.28 +/-6.67 11.4 pCi/g DFAI 08/09/06 1128 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0. 0813 +/-0.0797 0.0634 +/-0.0797 0.132 pCi/g ATH2 08/09/06 0324 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 +/-48.1 32.0 +/-48.1 65.9 pCi/g MXPI 08/12/06 1633 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 +/-6.39 5.18 +/-6.40 10.6 pCi/g MXPI 08/11/06 0738 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U ).139 +/-0.213 0.173 +/-0.213 0.360 pCi/g EGD1 08/11/06 2027 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I l-RC Modified 3 DOE EML HASL-300, Pu- I1-RC Modified 4 EPA 906.0 Modified Page 67 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANKO 1204 Sample ID: 168404001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 80 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15/%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 98 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 68 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-011F Project: YANKO 1204 Sample ID: 168404002 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 17.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americitum-241 U 0.120 +/-0.154 0.0683 +1-0.155 0.251 pCi/g BXLI 08/11/06 1336 555696 1 Curium-242 U -0.0146 +/-0.122 0.0692 +/-0.123 0.303 pCi/g Curium-243/244 U -0.0103 +/-0.0861 0.0487 +/-0.0862 0.213 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0121 +/-0.125 0.127 +/-0.125 0.344 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0254 +/-0.0675 0.0381 +/-0.0675 0.167 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 +/-7.02 5.56 +/-7.05 11.7 pCi/g BXLI 08/16/06 1237 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 +/-7.03 5.94 +/-7.03 12.8 pCi/g DFA I 08/09/06 1143 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 +/-0.0828 0.0685 +/-0.0828 0.143 pCi/g ATH2 08/09/06 0426 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 +/-47.7 31.9 +/-47.7 65.7 pCi/g MXPI 08/12/06 1649 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 +/-5.81 4.68 +/-5.81 9.60 pCi/g MXPI 08/11/06 0825 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 +/-0.203 0.164 +/-0.203 0.341 pCi/g EGD1 08/11/06 2043 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-11-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01IF Proiect: YANK01204 Sample ID: 168404002 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%- 125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15/-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 88 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%- 125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%°-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 70 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANK01204 Sample ID: 168404003 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 23.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 +/-0.117 0.153 +/-0.117 0.488 pCi/g BXLI 08/13/06 0819 555696 1 Curium-242 U 0.112 +/-0.315 0.245 +/-0.315 0.781 pCi/g Curium-243/244 U 0.0217 +/-0.206 0.205 +/-0.206 0.594 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.061 +/-0.189 0.176 +/-0.189 0.449 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0551 +/-0.103 0.0584 +/-0.103 0.215 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-5.73 4.40 +/-5.78 9.25 pCi/g BXLI 08/16/06 1253 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00343 +/-0.0203 0.0172 +/-0.0203 0.036 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 +/-8.25 6.87 +/-8.25 14.8 pCi/g DFA I 08/09/06 1159 554582 5 Liquid Scint C14, SolidAlFSS Carbon-14 U 0.0937 +/-0.0813 0.0642 +/-0.0813 0.134 pCi/g ATH2 08/09/06 0529 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 +/-51.2 34.2 +/-51.2 70.4 pCi/g MXP1 08/12/06 1706 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 +/-7.12 6.58 +/-7.13 13.6 pCi/g MXPI 08/11/06 0912 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 +/-0.198 0.169 +/-0.198 0.351 pCi/g EGD 1 08/11/06 2059 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 71 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANK01204 Sample ID: 168404003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 42 (15%-125%/6)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 92 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 113 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 59 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 71 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 73 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Proiect: YANK01204 Sample ID: 168404004 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 22.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 +/-0.155 0.139 +/-0.155 0.387 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.113 +/-0.181 0.0733 +/-0.182 0.321 pCi/g Curium-243/244 U 0.180 +/-0.239 0.181 +/-0.240 0.472 pCi/g Alphaspec Pu, Solid-ALL FSS 0.118 Plutonium-238 U 0.0196 +/-0.121 +/-0.121 0.324 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0326 +/-0.0639 0.00 +/-0.064 0.0884 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 +/-6.19 4.86 +/-6.22 10.2 pCi/g BXL1 08/16/06 1309 555698 3 Rod Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00477 +/-0.0216 0.0179 +/-0.0216 0.0375 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 +/-7.06 5.85 +/-7.06 12.6 pCi/g DFAI 08/09/06 1215 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 +/-0.0912 0.0699 +/-0.0913 0.146 pCi/g ATH2 08/09/06 0632 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 +/-42.7 28.7 +/-42.7 59.2 pCi/g MXPI 08/12/06 1722 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 +/-10.1 10.3 +/-10.1 21.6 pCi/g MXPI 08/11/06 1001 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 +/-0.213 0.170 +/-0.213 0.353 pCi/g EGDI 08/11/06 2115 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 74 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of AnalTsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANKO 1204 Sample ID: 168404004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-1Il-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 78 (15%o-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 101 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 58 (25%-I125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 62 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-I125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANKO 1204 Sample ID: 168404004 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.

Page 76 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Proiect: YANKO 1204 Sample ID: 168404005 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 15.4%

Parameter Qualifier Rcesuit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0 '.036 +/-0.123 0.157 +/-0.123 0.437 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.i 0169 +/-0.033 0.080 +/-0.0331 0.350 pCi/g Curium-243/244 U -0. 0129 +/-0.227 0.247 +/-0.227 0.619 pCi/g AIphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.( 0217 +/-0.163 0.181 +/-0.163 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.( 0708 +/-0.0791 0.128 +/-0.0795 0.337 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.52 +/-6.00 4.57 +/-6.07 9.61 pCi/g BXLI 08/16/06 1326 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0'.854 +/-5.88 4.87 +/-5.88 10.5 pCi/g DFA I 08/09/06 1231 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 0.347 +/-0.097 0.0674 +/-0.0972 0.141 pCi/g ATH2 08/09/06 0734 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U - 1.57 +/-46.0 30.7 +/-46.0 63.2 pCi/g MXPI 08/12/06 1738 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.39 +/-7.62 7.40 +/-7.62 15.5 pCi/g MXPI 08/11/06 1017 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.( 0198 +/-0.187 0.156 +/-0.187 0.324 pCi/g EGD1 08/11/06 2131 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I l-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 77 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANKO 1204 Sample ID: 168404005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15 %-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 95 (15%- 125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 78 (15%-125%o)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15°-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 78 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Proiect: YANKO 1204 Sample ID: 168404006 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 26.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0 +/-0.203 0.178 +/-0.203 0.469 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0 +/-0.0301 0.0729 +/-0.0302 0.319 pCi/g Curium-243/244 U -0 +/-0.251 0.300 +/-0.251 0.713 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0 .0466 +/-0.213 0.210 +/-0.213 0.521 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -' 0.142 +/-0.108 0.191 +/-0.109 0.483 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.64 +/-6.53 5.16 +/-6.57 10.8 pCi/g BXLI 08/16/06 1342 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -2.9 +/-7.59 6.60 +/-7.59 14.2 pCi/g DFAI 08/09/06 1247 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0. 0352 +/-0.0868 0.0713 +/-0.0868 0.149 pCi/g ATH2 08/09/06 0837 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 1.88 +/-46.8 31.3 +/-46.8 64.4 pCi/g MXPI 08/12/06 1754 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 3.88 +/-7.46 7.40 +/-7.46 15.5 pCi/g MXPI 08/11/06 1033 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0894 +/-0.198 0.163 +/-0.198 0.338 pCi/g EGD1 08/11/06 2147 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-1 I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 79 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANKO 1204 Sample ID: 168404006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 72 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 72 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 94 (25%-I 25%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 ( 15°%/- 125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 80 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-01OF Project: YANK01204 Sample ID: 168404007 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 56.2%

Parameter Qualifier Reesult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0 ).128 +/-0.0939 0.142 +/-0.0942 0.385 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.i 0115 +/-0.128 0.147 +/-0.128 0.450 pCi/g Curium-243/244 U -0.(0333 +/-0.122 0.149 +/-0.122 0.401 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(0548 +/-0.169 0.158 +/-0.170 0.403 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.(0195 +/-0.121 0.117 +/-0.121 0.322 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.4 +/-6.89 5.27 +/-6.97 11.1 pCi/g BXLI 08/16/06 1358 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.86 5.76 +/-6.86 12.4 pCi/g DFA1 08/09/06 1303 554582 Liquid Scint C14, SolidAILFSS Carbon-14 U 0.10636 +/-0.0801 0.0644 +/-0.0801 0.135 pCi/g ATH2 08/09/06 1017 554583 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 36.1 +/-44.1 28.7 +/-44.1 59.0 pCi/g MXPI 08/12/06 1811 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.26 +/-10.2 10.0 +/-10.2 20.9 pCi/g MXPl 08/11/06 1049 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U - 0.05 +/-0.199 0.169 +/-0.199 0.351 pCi/g EGD1 08/11/06 2203 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-l 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 81 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010F Project: YANKO 1204 Sample ID: 168404007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15'-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 92 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15/-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 82 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Project: YANKO 1204 Sample ID: 168404008 Client ID: YANKOO I Matrix: SE Vol. Recv.:

Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 32.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 +/-0.219 0.231 +/-0.219 0.608 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U -0.04 +/-0.0554 0.134 +/-0.0557 0.494 pCi/g Curium-243/244 U 0.0634 +/-0.261 0.249 +/-0.261 0.646 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 +/-0.106 0.160 +/-0.106 0.434 pCi/g BXL1 08/11/06 1633 555697 2 Plutonium-239/240 U -0.0287 +/-0.098 0.127 +/-0.0981 0.369 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 +/-8.01 6.48 +/-8.02 13.6 pCi/g BXL1 08/16/06 1415 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 +/-6.38 4.90 +/-6.38 10.6 pCi/g DFAI 08/09/06 1319 554582 4 Liquid Scint C04, SolidAllFSS Carbon-14 U 0.0892 +/-0.0827 0.0655 +/-0.0827 0.137 pCi/g ATH2 08/09/06 1424 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 +/-46.3 30.6 +/-46.3 62.9 pCi/g MXPI 08/12/06 1827 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 +/-7.91 7.77 +/-7.91 16.2 pCi/g MXPI 08/11/06 1106 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134 +/-0.192 0.167 +/-0.192 0.346 pCi/g EGD1 08/11/06 2218 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Project: YANK01204 Sample ID: 168404008 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-i, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 61 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 74 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-I125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 84 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Proiect: YANKO 1204 Sample ID: 168404009 Client ID: YANKOOI Matrix: SE Vol. Recv.:

Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 16.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U - 0.0851 +/-0.136 0.106 +/-0.136 0.390 pCi/g BXL1 08/16/06 0949 557837 1 Curium-242 U - 0.0253 +/-0.0495 0.120 +/-0.0496 0.525 pCi/g Curium-243/244 U - 0.0479 +/-0.0542 0.131 +/-0.0545 0.443 pCi/g Alphaspec Pu, Solid-ALL FSS pCi/g Plutonium-238 U 0. 0183 +/-0.113 0.110 +/-0.113 0.303 BXL1 08/11/06 1633 555697 3 Plutonium-239/240 U 0 .0' 0122 +/-0.0662 0,0694 +/-0.0662 0.221 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.43 +/-5.83 4.67 +/-5.85 9.82 pCi/g BXLI 08/16/06 1431 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U - -2.02 +/-6.67 5.76 +/-6.67 12.4 pCi/g DFAI 08/09/06 1335 554582 5 Liquid Scint C14, SolidAllFSS Carbon- 14 01.142 +/-0.0798 0.061 +/-0.0799 0.127 pCi/g ATH2 08/09/06 1719 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 12.6 +/-47.6 31.7 +/-47.6 65.3 pCi/g MXPI 08/12/06 1843 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.70 +/-9.56 9.31 +/-9.56 19.5 pCi/g MXPI 08/11/06 1122 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0' 0659 +/-0.185 0.156 +/-0.185 0.323 pCi/g EGDI 08/11/06 2234 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-0I -RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 EPA 906.0 Modified Page 85 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANK01204 Sample ID: 168404009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Arnericium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%- 125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 93 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-.125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 81 (15%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 86 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvqiq Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Proiect: YANKO 1204 Sample ID: 168404010 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 05-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 34.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U C'.129 +/-0.195 0.0758 +/-0.196 0.332 pCi/g BXL1 08/16/06 0949 557837 1 Curium-242 U 01.103 +/-0.202 0.00 +/-0.203 0.280 pCi/g Curium-243/244 U -0.1 0161 +/-0.0316 0.0766 +/-0.0317 0.335 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.i 0276 +/-0.0711 0.0967 +/-0.0712 0.275 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.010359 +/-0.113 0.118 +/-0.113 0.317 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-24I 14.9 +/-6.37 4.64 +/-6.51 9.75 pCi/g BXL1 08/16/06 1447 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.06 5.09 +/-6.06 10.7 pCi/g DFA1 08/10/06 2150 554582 5 Liquid Scint C14, SolidA/lFSS Carbon-14 U 0 .107 +/-0.0846 0.0664 +/-0.0846 0.139 pCi/g ATH2 08/09/06 1822 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 15.1 +/-41.4 27.5 +/-41.4 56.6 pCi/g MXPI 08/12/06 1900 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0 .258 +/-0.225 0.179 +/-0.225 0.373 pCi/g EGD1 08/11/06 2251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu-11-RC Modified 4 DOE EML HASL-300, Pu-I I-RC Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified Page 87 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Project: YANKO 1204 Sample ID: 168404010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300. Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 77 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 103 (25/- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 71 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 88 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Proiect: YANK01204 Sample ID: 168404011 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 35.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. +/-0.192 0.152 +/-0.193 0.426 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. +/-0.142 0.132 +/-0.142 0.446 pCi/g Curium-243/244 U -0. +/-0.202 0.240 +/-0.203 0.603 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. +/-0.096 0.125 +/-0.096 0.328 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium- 2 39/240 U -0. +/-0.114 0.137 +/-0.114 0.353 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 11.5 +/-6.72 5.08 +/-6.80 10.7 pCi/g BXLI 08/16/06 1504 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U 0.00 +/-5.92 4.97 +/-5.92 10.7 pCi/g DFAI 08/09/06 1407 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U -0. 0238 +/-0.0745 0.0636 +/-0.0745 0.133 pCi/g ATH2 08/09/06 1924 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U - -10.7 +/-40.9 27.5 +/-40.9 56.8 pCi/g MXPI 08/12/06 1916 555722 6 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0. 0956 +/-0.211 0.174 +/-0.211 0.361 pCi/g EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified 6 DOE RESL Fe-I, Modified Page 89 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO1204 Sample ID: 168404011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-1125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 90 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com UPrtifirntt nf Anal civ

.I.

Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANKO 1204 Sample ID: 168404012 Client ID: YANKOO 1 Matrix: SE Vol. Recv.:

Collect Date: 1 I-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 33%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 +/-0.155 0.166 +/-0.155 0.458 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0192 +/-0.145 0.135 +/-0.145 0.455 pCi/g Curium-243/244 U 0.013 +/-0.268 0.281 +/-0.268 0.687 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 +/-0.0493 0.0279 +/-0.0494 0.122 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0186 +/-0.0492 0.0278 +/-0.0493 0.122 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 +/-6.90 5.13 +/-7.01 10.8 pCi/g BXLI 08/16/06 1520 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0151 +/-0.0146 0.0114 +/-0.0146 0.0242 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 +/-8.36 6.70 +/-8.36 14.5 pCi/g DFA1 08/09/06 1422 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 +/-0.0755 0.0613 +/-0.0755 0.128 pCi/g ATH2 08/09/06 2027 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 +/-40.6 26.8 +/-40.6 55.2 pCi/g MXPI 08/12/06 1932 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 +/-0.203 0.168 +/-0.203 0.348 pCi/g EGD1 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 91 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANK01204 Sample ID: 168404012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 61 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 94 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%- 125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 92 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Proiect: YANKO 1204 Sample ID: 168404013 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 28.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 +/-0.242 0.230 +/-0.243 0.574 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U 0.0957 +/-0.220 0.171 +/-0.220 0.509 pCi/g Curium-243/244 U -0.073 +/-0.214 0.256 +/-0.214 0.627 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00629 +/-0.0529 0.0299 +/-0.0529 0.131 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0262 +/-0.0513 0.00 +/-0.0514 0.0709 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 +/-6.66 4.95 +/-6.77 10.4 pCi/g BXLI 08/16/06 1536 555698 3 Rad Gas Flow Proportional Counting GFPC,St90, solid-ALL FSS Strontium-90 U 0.0205 +/-0.0151 0.0116 +/-0.0151 0.0246 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 +/-7.98 6.65 +/-7.98 14.4 pCi/g DFA1 08/09/06 1438 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0271 +/-0.0759 0.0625 +/-0.0759 0.131 pCi/g ATH2 08/09/06 2129 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 +/-150 102 +/-150 210 pCi/g MXPI 08/12/06 1949 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628 +/-0.200 0.165 +/-0.200 0.343 pCi/g EGD1 08/11/06 2338 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 93 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Proiect: YANKO 1204 Sample ID: 168404013 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (150-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%- 125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> .Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 94 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-00IF Project: YANKO 1204 Sample ID: 168404014 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 27.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 +/-0.227 0.238 +/-0.227 0.628 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0854 +/-0.167 0.00 +/-0.168 0.231 pCi/g Curium-243/244 U 0.0361 +/-0.242 0.241 +/-0.242 0.634 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 +/-0.181 0.143 +/-0.182 0.331 pCi/g BXL1 08/11/06 2250 555697 2 Plutonium-239/240 U -0.0342 +/-0.0865 0.0951 +/-0.0866 0.235 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 +/-6.44 4.78 +/-6.54 10.0 pCi/g BXLI 08/16/06 1553 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0128 +/-0.0141 0.0125 +/-0.0141 0.0262 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.548 +/-7.50 6.25 +/-7.50 13.5 pCi/g DFAI 08/09/06 1454 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0555 +/-0.0809 0.0655 +/-0.0809 0.137 pCi/g ATH2 08/09/06 2232 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -18.1 +/-47.6 32.3 +/-47.6 66.6 pCi/g MXPI 08/12/06 2005 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134 +/-0.205 0.167 +/-0.205 0.347 pCi/g EGD1 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 95 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Project: YANK01204 Sample ID: 168404014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am24I, Cm, Solid ALL 50 (15/-,125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 96 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Proiect: YANKO 1204 Sample ID: 168404015 Client ID: YANK001 Matrix: SE Vol. Recv.:

Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 28.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 +/-0.184 0.140 +/-0.184 0.386 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.0547 +/-0.141 0.192 +/-0.141 0.544 pCi/g Curium-243/244 U -0.126 +/-0.184 0.245 +/-0.185 0.597 pCi/g AIphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 +/-0.126 0.122 +/-0.126 0.291 pCi/g BXL1 08/11/06 2250 555697 2 Plutonium-239/240 U 0.0867 +/-0.0869 0.0406 +/-0.0872 0.128 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-6.16 4.77 +/-6.21 10.0 pCi/g BXLI 08/16/06 1609 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00771 +/-0.0144 0.0124 +/-0.0144 0.0263 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 +/-6.17 5.11 +/-6.17 11.0 pCi/g DFAI 08/09/06 1510 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0162 +/-0.0763 0.0633 +/-0.0763 0.132 pCi/g ATH2 08/09/06 2334 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 +/-49.3 32.5 +/-49.3 67.0 pCi/g MXPI 08/12/06 2021 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 +/-0.206 0.171 +/-0.206 0.354 pCi/g EGDI 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I -RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 97 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 81 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25o%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

Page 98 of 105

I QUALITY CONTROL DATA Page 99 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: August 21, 2006 Client : Connecticut Yankee Atomic Power Page I of 6 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 168404 VrnN Q* In*(!nn*

C Units RPD% REC% Range Anist Date Time

. ....... .I l* alm.jp. eUa Q Rad Alpha Spec Batch 555696 QC120! 153130 168340011 DUP Americium-241 U -0.000522 U 0.0578 pCi/g 204 (0%- 100%) BXLI 08/11/06 14:34 Uncert: +/-0.0385 +/-0.278 TPU: +/-0.0385 +/-0.279 Curium-242 U 0.00 U -0.0405 pCi/g 200 (0%- 100%)

Uncert: +/-0.0756 +/-0.0562 TPU: +/-0.0756 +/-0.0565 Curium-243/244 U -0.0177 U -0.0517 pCi/g 98 (0%- 100%)

Uncert: +/-0.0764 +/-0.257 TPU: +/-0.0765 +/-0.257 QC1201153i32 LCS Americium-241 12.8 12.8 pCi/g 100 (75%-125%)

Uncert: +/- 1.84 TPU: +/-2.70 Curium-242 U -0.0328 pCi/g Uncert: +/-0.0454 TPU: +/-0.0457 Curium-243/244 15.5 14.3 pCi/g 92 (75%-125%)

Uncert: +/-1.94 TPU: +/-2.92 QC1201153129 MB Americium-241 U 0.0471 pci/g Uncert: +/-0.157 TPU: +/-0.157 Curium-242 U -0.0469 pCi/g Uncert: +/-0.0459 TPU: +/-0.0464 Curium-243/244 U -0.00385 pCi/g Uncert: +/-0.210 TPU: +/-0.210 QC1201153131 168340011 MS Americium-241 13.3 U -0.000522 12.0 pCi/g 91 (75%-125%)

Uncert: +/-0.0385 +/-1.38 TPU: +/-0.0385 +/-2.08 Curium-242 U 0.00 U 0.0427 pCi/g Uncert: +/-0.0756 +/-0.0837 TPU: +/-0.0756 +/-0.0839 Curium-243/244 16.1 U -0.0177 15.9 pci/g 99 (75%-125%)

Uncert: +/-0.0764 +/-1.58 TPU: +/-0.0765 +/-2.61 Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0% - 100%) BXLI 08/11/0622:51 Page 100 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 2 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 555697 Uncert: +/-0.0215 +/-0.0465 TPU: +/-0.0216 +/-0.0466 Plutonium-239/240 U 0.0414 U -0.0489 pCi/g 2410 (0%- 100%)

Uncert: +/-0.0934 +/-0.124 TPU: +/-0.0935 +/-0.124 QC1201153136 LCS Plutonium-238 U 0.155 pCi/g (75%-125%)

Uncert: +/-0.141 TPU: +/-0.142 Plutonium-239/240 11.8 11.5 pCi/g 98 (75%-125%)

Uncert: +/-0.856 TPU: +/-1.32 QC1201153133 MB Plutonium-238 U 0.0552 pCi/g 08/11/06 22:50 Uncert: +/-0.186 TPU: +/-0.186 Plutonium-239/240 U -0.0978 pCi/g Uncert: +/-0.0892 TPU: +/-0.0899 QC1201153135 168340011 MS Plulonium-238 u -0.0155 U 0.0539 pCi/g (75%-125%) 08/11/06 22:51 Uncert: +/-0.0215 +/-0.112 TPU: +/-0.0216 +/-0.112 Plutonium-239/240 12.3 U 0.0414 10.3 pCi/g 84 (75%-125%)

Uncert: +/-0.0934 +/-0.796 TPU: +/-0.0935 +/-1.19 Batch 555698 QC1201153138 168340011 DUP Plutonium-241 U 7.28 U 10.1 pCi/g 0 (0% - 100%) BXL I 08/16/06 16:41 Uncert: +/-6.30 +/-6.39 TPU: +/-6.35 +/-6.46 QC1201153140 LCS Plutonium-241 137 145 pCi/g 106 (75%-125%) 08/16/06 17:14 Uncert: +/-12.5 TPU: +/-19.9 QC1201153137 MB Plutonium-241 U 8.57 pCi/g 08/16/06 16:25 Uncert: +/-6.93 TPU: +/-6.98 QC1201153139 168340011 MS Plutonium-241 138 U 7.28 142 pCi/g 103 (75%-125%) 08/16/06 16:58 Uncert: +/-6.30 +/-12.4 TPU: +/-6.35 +/-19.7 Batch 557837 QC1201158317 168404009 DUP Americium-241 U -0.0851 U 0.167 pCi/g 616 (0%- 100%) BXLI 08/16/06 09:49 Uncert: +/-0.136 +/-0.220 TPU: +/-0.136 +/-0.221 Curium-242 U -0.0253 U 0.241 pCi/g 247 (0%- 100%)

Page 101 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 3 of 6 Parmname NOM Samnle Oual O'C Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Uncert: +/-0.0495 +/-0.334 TPU: +/-0.0496 +/-0.335 Curium-243/244 U -0.0479 U 0.0761 pCi/g 879 (0%- 100%)

Uncert: +/-0.0542 +/-0.149 TPU: +/-0.0545 +/-0.149 QC1201158319 LCS Americium-241 24.5 25.4 pCi/g 104 (75%-125%)

Uncert: +/-2.47 TPU: +/-4.16 Curium-242 U 0.0477 pCi/g Uncert: +/-0.127 TPU: +/-0.127 Curium-243/244 29.7 27.0 pCi/g 91 (75%-125%)

Uncert: +/-2.54 TPU: +/-4.38 QCI201158316 MB Americium-241 U 0.234 pCi/g Uncert: +/-0.275 TPU: +/-0.277 Curium-242 U 0.00 pCi/g Uncert: +/-0.152 TPU: +/-0.152 Curium-243/244 U -0.0551 pCi/g Uncert: +/-0.0624 TPU: +/-0.0628 QC1201158318 168404009 MS Americium-241 26.4 u -0.0851 29.1 pCi/g 110 (75%-125%)

Uncert: +/-0.136 +/-2.97 TPU: +/-0.136 +/-5.01 Curium-242 u -0.0253 U 0.126 pCi/g Uncert: +/-0.0495 +/-0.247 TPU: +/-0.0496 +/-0.248 Curium-243/244 32.4 U -0.0479 31.7 pCi/g 98 (75%-125%)

Uncert: +/-0.0542 +/-3.12 TPU: +1-0.0545 +/-5.39 Rad Gas Flow Batch 556350 QC0201154645 168404003 DUP Strontium-90 U -0.00343 U -0.00637 pCi/g 0 (0%- 100%) BXFI 08/14/06 08:33 Uncert: +/-0.0203 +/-0.0152 TPU: +/-0.0203 +/-0.0152 QCl201154647 LCS Strontium-90 1.56 1.30 pCi/g 83 (75%-125%)

Uncert: +/-0.0563 TPU: +/-0.0881 QC1201154644 MB Strontium-90 U 0.0176 pCi/g Uncert: +/-0.018 TPU: +/-0.018 Page 102 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder: 168404 Page 4 of 6 Parm na me NOM Samnle Oual QC Units RPD% REC% Range Anist Date Time Parmnarne NOM Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 1.58 U -0.00343 1.29 pCi/g 82 (75%-125%)

Uncert: +/-0.0203 +/-0.0535 TPU: +/-0.0203 +/-0.0813 Rad Liquid Scintillation Batch 554580 QC12O1150562 168340012 DUP Technetium-99 U 0.0338 U 0.266 pCi/g 0 (0% - 100%) EGDI 08/12/06 00:42 Uncert: +/-0.192 +/-0.226 TPU: +/-0.192 +/-0.226 QC1201150564 LCS Technetium-99 13.1 13.6 pCi/g 103 (75%-125%) 08/12/06 01:14 Uncert: +/-0.496 TPU: +/-0.599 QC1201150561 MB Technetium-99 U 0.0311 pCi/g 08/12/06 00:26 Uncert: +/-0.177 TPU: +/-0 177 QC1201150563 168340012 MS Technetium-99 13.0 U 0.0338 12.0 pCi/g 92 (75%-125%) 08/12/06 00:58 Uncert: +/-0.192 +/-0.523 TPU: +/-0.192 +/-0.602 Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 U 1.62 pCi/g 0 (0% - 100%) DFAI 08/09/06 15:42 Uncert: +/-8.20 +/-7.47 TPU: +/-8.20 +/-7.47 QC1201150572 LCS Tritium 68.3 76.2 pCi/g II1 (75%-125%) 08/09/06 16:14 Uncert: +/-14.0 TPU: +/-14.1 QC1201150569 MB Tritium U 0.586 pCi/g 08/09/06 15:26 Uncert: +/-8.01 TPU: +/-8.01 QC1201150571 168340011 MS Tritium 61.3 U 1.77 61.8 pCi/g 101 (75%-125%) 08/09/06 15:58 Uncert: +/-8.20 +/-12.2 TPU: +/-8.20 +/-12.3 Batch 554583 QC1201150574 168404003 DUP Carbon-14 U 0.0937 1J 0.0422 pCi/g 0 (0%- 100%) ATH2 08/10/06 01:39 Uncert: +/-0.0813 +/-0.075 TPU: +/-0.0813 +/-0.0751 QC1201150576 LCS Carbon-14 7.27 7.14 pCi/g 98 (75%-125%) 08/10/06 03:00 Uncert: +/-0.508 TPU: +/-0.520 QC1201150573 MB Page 103 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 554583 Carbon-14 U -0.0315 pCi/g Uncert: +/-0.0776 TPU: +/-0.0776 QC1201150575 168404003 MS Carbon- 14 15.1 U 0.0937 13.8 pCi/g 92 (75%-125%) 08/10/06 02:43 Uncert: +/-0.0813 +/-1.00 TPU: +/-0.0813 +/-1.03 Batch 555722 QC1201153223 168340012 DUP Iron-55 U -26.5 U 5.83 pCi/g 0 (0%- 100%) vAXPI 08/12/06 20:54 Uncert: +/-65.1 +/-36.9 TPU: +/-65.1 +/-36.9 QC1201153225 LCS Iron-55 641 660 pCi/g 103 (75%-125%) 08/12/06 21:27 Uncert: +/-56.2 TPU: +/-67.2 QC)201153222 MB Iron-55 U 18.2 pCi/g 08/12/06 20:38 Uncert: +/-39.6 TPU: +/-39.6 QC1201153224 168340012 MS Iron-55 717 U -26.5 688 pCi/g 96 (75%-125%) 08/12/06 21:11 Uncert: +/-65.1 +/-60.2 TPU: +/-65.1 +/-71.6 Batch 555723 QC1201153227 168340012 DUP Nickel-63 U 3.79 U 6.68 pCi/g 0 (0% - 100%) VlXPI 08/11/06 11:55 Uncert: +/-5.39 +/-7.43 TPU: +/-5.40 +/-7.43 QCl201153229 LCS Nickel-63 512 479 pCi/g 94 (75%-125%) 08/11/06 12:27 Uncert: +/-22.4 TPU: +/-27.1 QC1201153226 MB Nickel-63 U 15.7 pCi/g 08/11/06 11:38 Uncert: +/-9.92 TPU: +/-9.93 QC1201153228 168340012 MS Nickel-63 530 U 3.79 511 pCi/g 96 (75%-125%) 08/11/06 12:11 Uncert: +/-5.39 +/-23.5 TPU: +/-5.40 +/-28.7 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported Result is greater than value reported Page 104 of 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 6 of 6 Ni"Mn Qý -1, I, IrjctýýZ nC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification x Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 105 of 105

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey Area Survey 0006 Survey Discharge Canal

  1. 9106 Unit#: Unit Name:

Sample Plan or WPIR#: 2006-021 SML #: 9106-0006-007 Sample

Description:

Comparison of split samples collected from sample measurement location #03 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0006-007F the comparison sample was 9106-0006-007FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 1.38E-02 8.55E-03 2 NONE - 9.80E-03 1.22E-02 0.71 N/A Co-60 1.58E-02 8.35E-03 2 NONE- 3.27E-02 1.36E-02 2.07 N/A Sr-90 -1.00E-02 6.25E-03 -2 NONE- 6.70E-03 8.55E-03 -0.67 N/A K-40 1.47E+01 5.55E-01 27 0.75 1.33 1.28E+01 5.40E-01 0.87 Y Comments/Corrective Actions: Neither Cs-137 nor Sr-90 were Table is provided to show acceptance criteria used identified in quantities greater than 2 standard deviations in to assess split samples.

either sample. Co-60 was not identified in a quantity greater than 2 standard deviations in sample # -007F. This would Resolution Agreement Range account for resolutions of less than 4. In consideration of Cs- 4 7 0.50 2.00 137, Co-60 & Sr-90 results, guidance for agreement ranges, 8 15 0.60 1.66 obtained from USNRC Inspection Procedure 84750, does not 16 50 0.75 1.33 address resolution ratios less than 4, therefore, a determination 51 200 0.80 1.25 of acceptability for such rations cannot be made. Since K-40 was found to be present at an acceptable level of agreement, no > 200 0.85 1.18 further action is warranted.

Performed By: Date: Reviewed By: Date WPIR - Work Plan and Inspection Record Z SML - Sample Measurement Location designation Page I of I

Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey 9106 Survey 0006 Survey Unit Discharge Canal Area#: Unit #: Name:

Sample Plan or WPIR#: 2006-0021 SML #: 9106-0006-018 Sample

Description:

Comparison of split samples collected from sample measurement location #18 and analyzec using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0006-018F, tht comparison sample was 9106-0006-018FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)

Value Error Range Value Error Ratio Cs-137 5.69E-02 1.33E-02 4 0.5 - 2 2.47E-02 1.15E-02 0.43 N Co-60 1.20E-01 1.92E-02 6 0.5 2 9.93E-02 1.57E-02 0.83 Y Sr-90 2.23E-03 4.32E-03 1 N/A 3.18E-03 3.75E-03 1.43 N/A K-40 1.74E+01 3.93E-01 44 0.75 1.33 1.13E+01 4.27E-01 0.65 N

4. 4 4 4 4 4. 4. 4
4. 4 4 4. 4 4 4. 4 I I
  • fl I Comments/Corrective Actions: The agreement level for Cs-137 Table is provided to show acceptance criteria used results may be explained by differences in realtive quantities of to assess split samples.

organic material constiuent to each sample. This does not necessarily indicate a problem with the sample preparation Resolution = Agreement Range methodology. On the other hand, the agreeement level for K-40 4 7 0.50 2.00 results may indicate an incomplete mixing of the sample aliqot 8 15 0.60 1.66 during on-site sample prep. In consideration of Sr-90 results, 16 50 0.75 1.33 guidance for agreement ranges, obtained from USNRC 51 200 0.80 1.25 Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such

> 200 0.85 1.18 rations cannot be made. This issue was dispositioned to the CR process on 9-25-06.

WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2c Preliminary Data Forms (1 Page)

Health Physics Procedure GPP-GGGR-R5]2 1-001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5121-OOl Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit: 9106- 0006 Survey Unit Name: Discharge Canal Classification: 2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement: Radionuclide Specific Number of Measurements: 15 Operational DCGL: 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Sr-90 Minimum Value: -2.82E-02 -1.34E-02 -1.OOE-02 Maximum Value: 5.20E-01 I1.94E+00 1.95E-02 Mean: 1.60E-01 3.43E-01 2.68E-03 Median: 1.30E-01 1.02E-01 1.67E-03 Standard Deviation: 1.69E-01 5.13E-01 7.5 1E-03 RADIONUCLIDE CONCENTRATION (pCi/g)

NUMBER Cs-137 Co-60 Sr-90 Identified? Identified? Identified?

9106-0006-OOIF -7.55E-04 -3.31 E-03 5.37E-04 N N N 9106-0006-003F 1.70E-01 7.22E-01 1.45E-02 Y Y N 9106-0006-004F 9.60E-02 4.38E-02 4.27E-03 Y N N 9106-0006-005F 4.09E-01 1.94E+00 1.95E-02 Y Y N 9106-0006-006F 1.30E-01 2.41 E-01 7.50E-04 Y Y N 9106-0006-007F 1.38E-02 1.58E-02 -1.OOE-02 N N N 9106-0006-008F 2.95E-01 6.35E-01 4.02E-03 Y Y N 9106-0006-009F 2.26E-01 1.02E-01 7.88E-03 Y Y N 9106-0006-01OF 5.20E-01 6.31 E-01 7.15E-03 Y Y Y 9106-0006-01 IF 3.12E-03 4.70E-02 2.44E-03 N Y N 9106-0006-012F 2.71 E-02 6.08E-03 -2.02E-03 Y N N 9106-0006-014F 1.79E-01 4.86E-01 -1.04E-03 Y Y N 9106-0006-015F 3.43E-01 2.21E-01 -3.81 E-03 Y Y N 9106-0006-019F -2.82E-02 -1.34E-02 1.67E-03 N N N 9106-0006-020F 1.28E-02 7.34E-02 -5.59E-03 N N N Performed By: &I1 E24'a Date: /10-90-,,'

Independent Review: Date: Z*e> 6

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2d

.Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium - 137 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 1.60E-01 pCi/g 6.OOE-01

,,5.00E-01 "

O 4.OOE-01 '-

0 3.OOE-01 .

"- 2.OOE-01 1.OOE-01 "

0 0.OOE+00

-1.00E-01 )204 , *3

61. 0011 10 Percentage Cs-1 37 Rank Percentage

-2.82E-02 1 3 %

-7.55E-04 2 10 %

3.12E-03 3 17 %

1.28E-02 4 23 %

1.38E-02 5 30 %

2.71 E-02 6 37 %

9.60E-02 7 43 %

1.30E-01 8 50 %

1.70E-01 9 57 %

1.79E-01 10 63 %

2.26E-01 11 70 %

2.95E-01 12 77 %

3.43E-01 13 83 %

4.09E-01 14 90 %

5.20E-01 15 97 %

Prepared By: i5A t~Zt Date: /0 0 Reviewed By: r 6ZDae Date: IýC3; ý 54

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cobalt - 60 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 3.43E-01 pCi/g 2.50E+00 -

.. 2.OOE+00 o 1.50E+00 0

1.00E+00 0

00.OOE+00 -.

20 40 60 80 10 Percentage Co-60 Rank Percentage

-1.34E-02 1 3 %

-3.31E-03 2 10 %

6.08E-03 3 17 %

1.58E-02 4 23 %

4.38E-02 5 30 %

4.70E-02 6 37 %

7.34E-02 7 43 %

1.02E-01 8 50 %

2.21 E-01 9 57 %

2.41E-01 10 63 %

4.86E-01 11 70 %

6.31E-01 12 77 %

6.35E-01 13 83 %

7.22E-01 14 90 %

1.94E+00 15 97 %

Prepared By: Date: /0 -, ,

Reviewed By: 6: ~ Pe~A,~L Date:

jr r

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Strontium - 90 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 2.68E-03 pCi/g 2.50E 2.OOE-02 -

. 1.50E-02 1.OOE-02 5.00E-03

  • O.OOE+00 , - - --

o-5.00E-03 *2 _ 4 6 _0 1 0

-1.OOE-02

-1.50E-02 Percentage Sr-90 Rank Percentage

-1.OOE-02 1 3 %

-5.59E-03 2 10 %

-3.81E-03 3 17 %

-2.02E-03 4 23 %

-1.04E-03 5 30 %

5.37E-04 6 37 %

7.50E-04 7 43 %

1.67E-03 8 50 %

2.44E-03 9 57 %

4.02E-03 10 63 %

4.27E-03 11 70 %

7.15E-03 12 77 %

7.88E-03 13 83 %

1.45E-02 14 90 %

1.95E-02 15 97 %

Prepared By: Date: 10- 0-,z c~ejZ9~sOT Reviewed By: Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs - 137 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.160 pCi/g 8

Cr g4-0*

u. 2 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.10 7 47%

0.20 3 20%

0.30 2 13%

0.40 1 7%

0.50 1 7%

0.60 1 7%

Total 15 100%

Prepared By: b.,0- /- Date: / - 2 &'-0, Reviewed By: Reviewed By: Date: 42ýex, '

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.343 pCi/g 10 8 II 4

0r 6 0) 0* 4 . I U.

2 0 I FELH I . . '

0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 Upper End Value (pCilg)

Upper End Observation Observation %

Value Frequency Frequency 0.00 2 13%

0.25 8 53%

0.50 1 7%

0.75 3 20%

1.00 0 0%

1.25 0 0%

1.50 0 0%

1.75 0 0%

2.00 1 7%

Total 15 100%

Prepared By: Date: 149 - 101a4 Reviewed By: *~A4 Date: / v3e)z- C

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Sr - 90 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.003 pCi/g 7

6

  • 5 a3-o~r3 2I 1-0 0.000 0.005 0.010 0.015 0.020 Upper End Value (pCi/g)

Upper End Observation Observation %

Value Frequency Frequency 0.000 5 33%

0.005 6 40%

0.010 2 13%

0.015 1 7%

0.020 1 7%

Total 15 100%

Prepared By: Date: /a - -?a - og/,

Reviewed By:-i *_Z Date:

x

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Physics Procedure GPP-GGGR-R5121 -000 Attachment A, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5 121-000 Attachment A, Rev. CY-00 1 MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 0006 Survey Unit Name: Discharge Canal WP&IR#: 2006-02 1 Classification : 2 IYPE I (a error):0.01 TYPE I (b error):0.05 I Radionuclides: Cs-137 Co-60 Sr-90 Survey Design DCGL (pCi/g): 5.38 2.59 1.05 Results Cs-137 Results Co-60 Results Sr-90 Weighted Sum (Ws) DCGL-Result Sign

-7.55E-04 -3.31 E-03 5.37E-04 -9.08E-04 1.00E+00 1.70E-01 7.22E-01 1.45E-02 3.24E-01 6.76E-0 1 9.60E-02 4.38E-02 4.27E-03 3.88E-02 9.6 1E-01 4.09E-0 1 1.94E+00 1.95E-02 8.43E-01 1.57E-01 1.30E-01 2.41 E-0 1 7.50E-04 1.18E-01 8.82E-01 1.38E-02 1.58E-02 -1.00E-02 -8.24E-04 1.00E+00 2.95E-01 6.35E-01 4.02E-03 3.04E-01 6.96E-01 2.26E-01 1.02E-0 1 7.88E-03 8.89E-02 9.11E-01 5.20E-01 6.3 1E-0I 7.15E-03 3.47E-0 1 6.53E-01 3.12E-03 4.70E-02 2.44E-03 2.1OE-02 9.79E-01 2.71E-02 6.08E-03 -2.02E-03 5.47E-03 9.95E-01 1.79E-01 4.86E-01 -1.04E-03 2.20E-0 I 7.80E-01 3.43E-0 1 2.2 1E-01 -3.81E-03 1.45E-01 8.55E-01

-2.82E-02 -1.34E-02 1.67E-03 -8.83E-03 1.01E+00 1.28E-02 7.34E-02 -5.59E-03 2.54E-02 9.75E-01 Number of Positive Differences (S+): 15 Critical Value: 11 Survey Unit: Meets Acceotance Criterion Performed By: &-/ xs,ýZ// Date: 0 - 06, Date: 15 Independent Review:

- 7 - -° -

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)

DQA Surface Soil Report Assessment Summary Site: 9106-0006 (19 mrem/yr)

Planner(s): Dale Randall Survey Unit Name: 9106-0006 Report Number: 1 Survey Unit Samples: 15 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment

Conclusion:

Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve

- 0.9

  • z~zIz.1
  • -. 1-u-

=.

.t0.8 *.4.I. -

I~0.7 I-_ _ _

, 0.6'

0.5

    • 0.6 ZijIll ___ -- ___ ZiZIL ___

0.4

,- 0.3 -i-I- - - _

_____ 'I _____

0.2 00.1 0 Z~ZL_--___

0.0 0.2 0.4 0.6 0.8 1.0 1.2 Unity Rule Sum-of-Ratios, including backgiund

- - Prospective Power E 1-beta . Actual Power

- LBGR , , Estimated Power DCGL ---- Retrospective Power COMPASS vl.0.0 1013012006 Page1I

DQA Surface Soil Report Survey Unit Data NOTE: Type = "S"indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Co-60 (pCi/g) Cs-137 (pCi/g) SrY-90 (pCi/g) 9106-0006-001 F S 0 0 0 9106-0006-003F S 0.72 0.17 0.01 9106-0006-004F S 0.04 0.1 0 9106-0006-005F S 1.94 0.41 0.02 9106-0006-006F S 0.24 0.13 0 9106-0006-007F S 0.02 0.01 -0.01 9106-0006-008F S 0.64 0.3 0 9106-0006-009F S 0.1 0.23 0.01 9106-0006-01 OF S 0.63 0.52 0.01 9106-0006:01 1F S 0.05 0 0 9106-0006-012F S 0.01 0.03 0 9106-0006-014F S 0.49 0.18 0 9106-0006-015F S 0.22 0.34 0 9106-0006-019F S -0.01 -0.03 0 9106-0006-020F S 0.07 0.01 -0.01 Modified Data (Unity Rule SOR)

NOTE: Type = "S"indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number Type Sum-of-Ratios (SOR) 9106-0006-001 F S 0 9106-0006-003F S 0.29 9106-0006-004F S 0.03 9106-0006-005F S 0.75 9106-0006-006F S 0.11 9106-0006-007F S 0 9106-0006-008F S 0.27 9106-0006-009F S 0.08 9106-0006-01 OF S 0.31 9106-0006-011 F S 0.02 9106-0006-012F S 0 9106-0006-014F S 0.2 9106-0006-015F S 0.13 9106-0006-019F S -0.01 9106-0006-020F S 0.02 COMPASS vl.0.0 10130/2006 Page 2

-'q VýJ DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=13 Mean (SOR) 0.15 N/A 0.15 Median (SOR) 0.08 N/A N/A Std Dev (SOR) 0.20 N/A 0.1 High Value (SOR) 0.75 N/A N/A Low Value (SOR) -0.01 N/A N/A COMPASS vl.0.0 1013012006 Page 3