ML061370464

From kanterella
Jump to navigation Jump to search
Analytical Results for Two Soil Samples Connected March 2, 2006 from Connecticut Yankee, Haddam Neck, Connecticut (Inspection Report No. DPR-61/2006001) (Rfta No.06-001)
ML061370464
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 05/08/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Laurie Kauffman
NRC Region 1
References
IR-06-001, RFTA-06-001
Download: ML061370464 (5)


Text

$3 O R I S E OAK RIDQE INSTITUTE FOR SCIENCE AND EDUCATION May 8,2006 Ms. Laurie Kauffman U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406

SUBJECT:

ANALYTICAL RESULTS FOR TWO SOIL SAMPLES COLLECTED MARCH 2,2006 FROM CONNECTICUT YANKEE, HADDAM NECK, CONNECTICUT

[INSPECTION REPORT NO. DPR-61/20060001] [RFTA NO. 06-0011

Dear Ms,

Kauffman:

The Oak Ridge Institute for Science and Education (ORISE) received two soil samples on March 22,2006 from Connecticut Yankee in Haddam Neck, Connecticut. The samples were analyzed by g a m m a spectroscopy (GS), for total radiostrontium by low background beta counting, and for tritium by liquid scintillation analysis. Sample identifications and collection data are presented in Table 1, the GS data are presented in Table 2, the total radiostrontium data are presented in Table 3, and the tritium data are presented in Table 4. The pertinent procedure references are provided in the specific tables.

ORISE's QC requirements were met for these analyses. The QC files are available for your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.91 84 with any questions or comments.

Sincerelv.

Dale Condra, Manager Laboratory RDC:WPI:ar Enclosure c:

T. McLaughlin, NRC/NMSS/TWFN 7F27 E. Abelquist, ORISE E. Knox-Davin, NRCINMSSITWFN 8A23 File 1696 S. Kirk, ORISE Voice: 865.241.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov

TABLE 1 ORISE Sample ID SAMPI;E IDENTIFICATIONS AND COLLECTION DATA CONNECTICUT YANREE HADDAM NECK, CONNECTICUT NRC Region I Collection Collection Sample ID Date Time I

I I

11 1G3GSOOO1 I 9520-0002-013-RACR I 3/2/2006 I 1453 iI

, - I - - - -

II 1696S0002' i 9520-0002-014-RACR I 3/2/2006 I 1455 11 Connecticut Yankee projects/l696/Data Tables/2006-05-08 Data Tables

6 w

g

8.

il w

I TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMIlTING RADIONUCLIDES IN SOXL SAMPLES BY GAMMA SPECTROSCOPY CPI, REVISION 15 CONnIEcTICTJT YANKEE HADDAM NECK, CONNECTICUT

TABLE 3 ORISE Sample ID 1696S0001 1696S0002 Total Radiostrontium Concentrations, TPUs, and MDGa NRC Region I Sample ID

@Ci/g) 9520-0002-013-RACR 0.09

_+

O. l l b (0.18) 9520-0002-0 14-RACR 0.16 It 0.11 (0.1 8)

Connecticut Yankee prqects/l696/Data Tables/2006-05-08 Data Tables

TABLE 4 ORISE Sample ID 169630001 CONCENTRATIONS OF TRITIUM (H-3)

IN SOIL SAMPLES BY LIQUID SCXNTILLATION ANALYSIS AP6, REVISION 15; CP4, REVISION 3 CONNECTICUT YANKEE HADDAM NECK, CONNECTICUT NRC Region I Sample H-3 Concentrationsa 9520-0002-01 S-RACR 3.6 i 2.gb (4.8)

ID

@ C W I 169680002 I 9520-0002-014-RACR I 2.7 2.8 (4.7) I]

The MDCS are in parentheses.

%Jnceaainties represent the 95% confidence level, based on total propagated uncertainties.

Connecticut Yankee pmjects/lG9G/Data Tables/2006-05-08 Data Tables