MONTHYEARML20101E5761992-05-31031 May 1992 Monthly Defueling Operations Rept for May 1992 for Fort St Vrain ML20096E8221992-04-30030 April 1992 Monthly Operating Rept for Apr 1992 for Fort St Vrain.W/ ML20100R7431992-03-31031 March 1992 Monthly Operating Rept for Mar 1992 for Fort St Vrain.W/ ML20090L0621992-02-29029 February 1992 Monthly Operating Rept for Feb 1992 for Fort St Vrain Unit 1 ML20092D0081992-01-31031 January 1992 Monthly Operating Rept for Jan 1992 for Fort St Vrain Nuclear Generating Station ML20091J6251991-12-31031 December 1991 Monthly Operating Rept for Dec 1991 for Fort St Vrain.W/ ML20094D6711991-11-30030 November 1991 Monthly Operating Rept for Nov 1991 for Fort St Vrain Unit 1 ML20086C5451991-10-31031 October 1991 Monthly Operating Rept for Oct 1991 for Fort St Vrain.W/ ML20085D9861991-09-30030 September 1991 Monthly Operating Rept for Sept 1991 for Fort St Vrain.W/ ML20082U6151991-08-31031 August 1991 Monthly Operating Rept for Aug 1991 for Fort St Vrain Unit 1 ML20082J0071991-07-31031 July 1991 Monthly Operating Rept for Jul 1991 for Fort St Vrain,Unit 1 ML20076C5621991-06-30030 June 1991 Monthly Operating Rept for June 1991 for Fort St Vrain.W/ ML20077F8391991-05-31031 May 1991 Monthly Operating Rept for May 1991 for Fort St Vrain ML20077C2591991-04-30030 April 1991 Monthly Operating Rept for Apr 1991 for Fort St Vrain ML20084U7831991-03-31031 March 1991 Monthly Operating Rept for Mar 1991 for Fort St Vrain ML20070P4811991-02-28028 February 1991 Monthly Operating Rept for Feb 1991 for Fort St Vrain.W/ ML20066G5561991-01-31031 January 1991 Monthly Operating Rept for Jan 1991 for Fort St Vrain Unit 1 ML20070A5841990-12-31031 December 1990 Monthly Operating Rept for Dec 1990 for Fort St Vrain Unit 1 ML20065R0331990-11-30030 November 1990 Monthly Operating Rept for Nov 1990 for Fort St Vrain Unit 1 ML20058H8821990-10-31031 October 1990 Monthly Defueling Operations Rept for Oct 1990 for Fort St Vrain Nuclear Generating Station ML20197H8721990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Fort St Vrain.W/ ML20059P0661990-09-30030 September 1990 Monthly Operating Rept for Sept 1990 for Fort St Vrain Nuclear Generating Station ML20059J1061990-08-31031 August 1990 Monthly Defueling Operating Rept for Aug 1990 for Fort St Vrain ML20058Q1661990-07-31031 July 1990 Monthly Operating Rept for Jul 1990 for Fort St Vrain ML20043G1141990-05-31031 May 1990 Monthly Operating Rept for May 1990 for Fort St Vrain. W/900615 Ltr ML20043A1121990-04-30030 April 1990 Monthly Operating Rept for Apr 1990 for Fort St Vrain. W/900515 Ltr ML20042E6421990-03-31031 March 1990 Monthly Defueling Operations Rept for Mar 1990 for Fort St Vrain.W/900413 Ltr ML20006F5441990-01-31031 January 1990 Monthly Defueling Operations Rept for Jan 1990 for Fort St Vrain.W/900215 Ltr ML19354E0791989-12-31031 December 1989 Monthly Operating Rept for Dec 1989 for Fort St Vrain, Unit 1.W/900112 Ltr ML19351A6521989-11-30030 November 1989 Monthly Operating Rept for Nov 1989 for Fort St Vrain, Unit 1.W/891206 Ltr ML19351A6531989-10-31031 October 1989 Monthly Operating Rept for Oct 1989 for Fort St Vrain, Unit 1.W/891206 Ltr ML19327B1821989-09-30030 September 1989 Monthly Defueling Operating Rept for Sept 1989 for Fort St Vrain Nuclear Generating Station ML20247H2111989-08-31031 August 1989 Monthly Operating Rept for Aug 1989 for Fort St Vrain ML20245L5831989-07-31031 July 1989 Monthly Operating Rept for Jul 1989 for Fort St Vrain Nuclear Generating Station ML20246Q2241989-06-30030 June 1989 Monthly Operating Rept for June 1989 for Fort St Vrain Unit 1 ML20245C4471989-05-31031 May 1989 Monthly Operating Rept for May 1989 for Fort St Vrain ML20247A8961989-04-30030 April 1989 Monthly Operating Rept for Apr 1989 for Fort St Vrain Nuclear Generating Station ML20244E2151989-03-31031 March 1989 Monthly Operating Rept for Mar 1989 for Fort St Vrain ML20236C3731989-02-28028 February 1989 Monthly Operating Rept for Feb 1989 for Fort St Vrain Nuclear Generating Station ML20235J6181989-01-31031 January 1989 Monthly Operating Rept for Jan 1989 for Fort St Vrain Nuclear Generating Station ML20206F6871988-10-31031 October 1988 Monthly Operating Rept for Oct 1988 for Fort St Vrain Nuclear Generating Station ML20207N3841988-09-30030 September 1988 Monthly Operating Rept for Sept 1988 for Fort St Vrain ML20154H5331988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Fort St Vrain.W/ ML20151V7821988-07-31031 July 1988 Monthly Operating Rept for Jul 1988 for Fort St Vrain Unit 1 ML20151E8951988-06-30030 June 1988 Monthly Operating Rept for June 1988 for Fort St Vrain ML20196C0671988-05-31031 May 1988 Monthly Operating Rept for May l988 for Fort St Vrain Nuclear Generating Station ML20154C2741988-04-30030 April 1988 Monthly Operating Rept 171 for Apr 1988 ML20151G1941988-03-31031 March 1988 Monthly Operating Rept for Mar 1988 ML20153B1361988-02-29029 February 1988 Monthly Operating Rept for Feb 1988 ML20149F8441988-01-31031 January 1988 Monthly Operating Rept 168 for Jan 1988 1992-05-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20196G6731997-07-0101 July 1997 Informs Commission That Decommissioning Process Has Been Completed at PSC of Colorado Fsvngs,Unit 1 Located in Town of Platteville in Weld County,Co ML20141K9961997-05-0505 May 1997 Safety Evaluation Supporting Amend 89 to License DPR-34 ML20140E1121997-04-10010 April 1997 Confirmatory Survey of Group Effluent Discharge Pathway Areas for Fsv Nuclear Station,Platteville,Co ML20134D1661997-01-30030 January 1997 Rev 1,Vol 6 to Final Survey Rept,Final Survey of Group E (Book 2A of 2) ML20137S6111996-12-31031 December 1996 Annual Rept Pursuant to Section 13 or 15(d) of Securities Exchange Act 1934, for Fy Ended Dec 1996 ML20134G6401996-10-29029 October 1996 Rev 0,Volume 6,Books 1 & 2 of 2 to Final Survey of Group E ML20134G6171996-10-29029 October 1996 Rev 2,Volume 1,Books 1 & 2 of 2 to Final Survey Description & Results ML20134G7271996-10-29029 October 1996 Rev 0,Volume 11,Book 1 of 1 to Final Survey of Group J ML20134G6861996-10-29029 October 1996 Rev 0,Volume 8,Books 1 & 2 of 2 to, Final Survey of Group G ML20134G6321996-10-26026 October 1996 Rev 1,Volume 5,Books 2 & 3 of 3 to Final Survey of Group D ML20133D7831996-10-22022 October 1996 Preliminary Rept - Orise Support of NRC License Insp at Fsv on 960930-1003 ML20116A4661996-07-19019 July 1996 Fsv Final Survey Exposure Rate Measurements ML20112J6861996-05-31031 May 1996 June 1996 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning.Rept Covers Period of 960216-0531 ML20112C1531996-05-17017 May 1996 Fsv Final Survey Exposure Rate Measurements ML20101G5521996-03-21021 March 1996 Confirmatory Survey Activities for Fsv Nuclear Station PSC Platteville,Co, Final Rept ML20097E3201996-01-31031 January 1996 Nonproprietary Fort St Vrain Technical Basis Documents for Piping Survey Instrumentation ML20095K4131995-12-26026 December 1995 Rev 3 to Decommissioning Plan ML20095H7211995-12-20020 December 1995 Revs to Fort St Vrain Decommissioning Fire Protection Plan Update ML20095K9751995-12-15015 December 1995 Fort St Vrain Project Update Presentation to NRC, on 951207 & 15 ML20096C1671995-12-13013 December 1995 Rev 4 to Decommissioning Fire Protection Plan ML20094M1651995-11-30030 November 1995 Nonproprietary Fsv Technical Basis Documents for Piping Survey Implementation ML20092F3461995-09-14014 September 1995 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning, Covering Period of 950516-0815.W/ ML20137H3531994-12-31031 December 1994 Partially Withheld, Rept of Independent Counsel Investigation Concerning Issues at Fort St Vrain Nuclear Generating Station Decommissioning Project, App D,Comments by Mkf & Westinghouse Team & Responses ML20137S2331994-12-31031 December 1994 Rept of Independent Counsel Investigation Concerning Issues at Fort St Vrain Nuclear Generating Station Decommissioning Project, Dec 1994 ML20029C6031993-12-31031 December 1993 1993 Annual Rept Public Svc Co of Colorado. W/940405 Ltr ML20058Q3791993-12-21021 December 1993 Rev 1 to Decommissioning Plan for Fort St Vrain Nuclear Generating Station ML20045B3641993-06-30030 June 1993 June 1993 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning. ML20045A4291993-06-0303 June 1993 LER 93-003-00:on 930505,new Source of Natural Gas Introduced within 0.5 Miles of ISFSI & Reactor Bldg W/O Prior NRC Approval.Caused by Field Routing of Natural Gas Pipe.Well Isolated by Well operator.W/930603 Ltr ML20077D1631993-05-10010 May 1993 Enforcement Conference, in Arlington,Tx ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20128D7191992-12-0101 December 1992 Safety Evaluation Approving Exemption from Requirement of 10CFR50.54(q) to Change to Biennial Emergency Plan Exercise Rather than Annual Following Completion of Next Scheduled Exercise at Plant ML20127P5861992-11-23023 November 1992 Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl ML20127F5691992-11-0303 November 1992 Informs Commission of Intent to Issue Order Approving Plant Decommissioning Plan & Corresponding Amend to License DPR-34 ML20101E5761992-05-31031 May 1992 Monthly Defueling Operations Rept for May 1992 for Fort St Vrain ML20096E8221992-04-30030 April 1992 Monthly Operating Rept for Apr 1992 for Fort St Vrain.W/ ML20095E9601992-04-17017 April 1992 Rev to Fort St Vrain Proposed Decommissioning Plan ML20100R7431992-03-31031 March 1992 Monthly Operating Rept for Mar 1992 for Fort St Vrain.W/ ML20090L0621992-02-29029 February 1992 Monthly Operating Rept for Feb 1992 for Fort St Vrain Unit 1 ML20092D0081992-01-31031 January 1992 Monthly Operating Rept for Jan 1992 for Fort St Vrain Nuclear Generating Station ML20102B2241992-01-22022 January 1992 Fort St Vrain Station Annual Rept of Changes,Tests & Experiments Not Requiring Prior Commission Approval Per 10CFR50.59, for Period 910123-920122 ML20094N6701991-12-31031 December 1991 Public Svc Co Annual Financial Rept for 1991 ML20091J6251991-12-31031 December 1991 Monthly Operating Rept for Dec 1991 for Fort St Vrain.W/ ML20094D6711991-11-30030 November 1991 Monthly Operating Rept for Nov 1991 for Fort St Vrain Unit 1 ML20090M1871991-11-20020 November 1991 FOSAVEX-91 Scenario for 1991 Plant Exercise of Defueling Emergency Response Plan ML20086D6891991-11-15015 November 1991 Proposed Decommissioning Plan for Fort St Vrain Nuclear Generating Station ML20085N1451991-11-0505 November 1991 Revised Ro:Operability Date of 910830 for Electric Motor Driven Fire Water Pump P-4501 Not Met.Pump Not Actually Declared Operable Until 911025.Caused by Unforseen Matl & Testing Problems.Equivalent Pump Available ML20086C5451991-10-31031 October 1991 Monthly Operating Rept for Oct 1991 for Fort St Vrain.W/ ML20085H6611991-10-10010 October 1991 Assessment of Mgt Modes for Graphite from Reactor Decommissioning ML20091D7671991-10-0101 October 1991 Rev B to Engineering Evaluation of Prestressed Concrete Reactor Vessel & Core Support Floor Structures for Proposed Sys 46 Temp Change ML20085D9861991-09-30030 September 1991 Monthly Operating Rept for Sept 1991 for Fort St Vrain.W/ 1997-07-01
[Table view] |
Text
_ _ _ -. - - -
o ,, - - - -
L_.
OPERATING dan REPORT DOCEIT NO. 50-267 DATI 790801 c0MPLIIID BY J. W. Cahm Tz:.EPHONE (303) 785-2253 OPERATING STATUS NoIzs
- 1. Unit Names Fort St. Vrain, Unit No. 1
- 2. Reporting Period: 790701 to 790731
- 3. Licensed Thermal Power Out): 842
- 4. Nameplate Rating (. Gross We): 342
- 5. Design F.lectrical Racing (Net We): 330
- 6. %=4== Dependable Capacity (Gross We): 342
- 7. Mar 1== Dependable Capacity (Net We): 330
- 8. If Changes occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:
None
- 9. Power Level To Which Restricted, If Any (Net We): 231
- 10. Reasons for Restrictions, If Any: Nuclear Regulatory Coc: mission restriction (70%) pending resolution of certain Final Safety Analysis Report and Technical Specification bases dis crep an cies. This unit is in startup phase following refueling and turbine generator overhaul.
This Month Year to Data Cumulative
- 11. Bours in Reporting Period 744 5,087 744
- 12. Number of sours Reactor was critical 696.9 1,843.3 15,317.0
- 13. Reac' r Reserve Shutdown Hours 0.0 0.0 0.0
- 14. sou . cenerator on-Line 85.6 750.9 8,593.5
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 16. cross Thernal Energy cenerated (Wa) 59,139 374,834 3,577,882
- 17. cross Electrical Energy cenerated (W a) 4,522 114,374 1,062,644
- 18. Net Electrical Energy cenerated (Wa) 0 101.177 952,628
- 19. Unit Service ractor 11.5% 11.5% 11.5%
- 20. ecie Avat14'o 111ty ractor 11.5% 11.5% 11.5%
- 1. cnic capacity ractor (tsing Mac Net) 0.0% 0.0% 0.0%
- 2. unit capacity ractor (using prR N :) 0.0% 0.0% 0.0%
- 23. Unit Forced Outage Rate 88.5% 88.5% 88.5%
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Ouration of Each):
Maintenance Shutdown, October 20, 1979, 30 days
- 25. If shut Down at End of Report Period, tatimated cate of Startup: 8-3-79
- $. Units In Test Status (Prior to Cc==arcial Operation): Torecast Acnieved
- NICA:. CRIUCA:.:n 740201 740131
- '::nA:. r:.Icnicir 7612 761211 cmc:x. cPERAUCN 790701 790701 r 7 90814 o s&( (c M
UNIT SHlfTIXMNS AND POWER~ REIAJCTUNS
" ~ ~ ~ " -
nocxET No. 50-267 UNIT NAME Fort S t. Vrain, Uni t No. 1 DATE 790801 COMPLETED B'/ J. W. Oahm REPORT PKWnt July, 1979 TELEPuoNE (303) 785-2253
" ~
HETHOD OF SillfTTING Im MN SYSTEH COMPONENT No. DATE TYPE DUHATION REASON REACTLR I.ER I U1DE (DDE CAUSE AND CORRECTIVE ACTION To PD: VENT PP:URREPCE 79-04 790201 F 542.3 A 4 79-03/03-L- 0 till PUMP XX Excessive gland leakage on "B" boiler feed pump concurrent with inoperable "C" boiler feed pump necessitated con". rolled reactor shutdown on Febru-
, ary 1,19 79, per LCO 4.3.2. Scheduled reactor shutdown for refueling was -
changed from March 1, 1979, to Febru-ary 1, 1979. Thus shutdown number 79-04 has extended through February, March, April, Hay, and June, 1979.
Upon completion of turbine generator overhaul and achievement of suf fi-cient reactor power, first genera-tioli following shutdown 79-04 oc-curred on 7-23-79.
79-05 790724 F 47.5 11 N/A N/A N/A N/A Turbine generater taken off 11ne due to field ground relay pauolems. Reac-tor was not shutdown.
79-06 790720 S 1.9 B N/A N/A N/A N/A Turbine generator taken off line in
!, order to perform overspeed tests.
Reactor not shutdown.
79-07 79072t F 53.0 11 N/A N/A N/A N/A Turbine tripped from high vibration.
g Loop 2 shutdown occurred. Reactor
,a power reduced to approximately 2% j v' _ _ ___
for Looy 2 recovery.
a L
s ugSuunxvis ann rWER,Rgu,CB),N1 toCKET NO. 50-267 _
UNIT NAttE Fo r t S t. Vrain, Unit No. 1 oats 790801 courtETto eT J. W. Gahm RErORT PR44Til July, 1979 (continued) TELEriioNE (303) 785-2253
~~
MET 110D OF SilVTf]NG lx1WN SYSTEH CotD'ONENT NO. DATE TYPE DURATION REASON REACTOR LER I CODE otDE CAUSE AND (11RRECTIVE ACTION TV rREVENT RECURRENCE 79-08 790731 F 13.7 11 3 N/A N/A N/A While transferring to partial arc on the main turbine generator, throttle ,
pressure dropped and load decreased 20 PM. During recovery, three circu- ,
lators tripped, Loop 2 shutdown, reactor scrammed, and turbine tripped.
Generator remained off line for balance of repo_rting period.
- ~
J
,s l
1
- s.
1 1
S UtDIARY : Plan to continue operation for electric production and fluctuation testing until release to continue power ascension testing above 70% received f rom Nuclear Regulatory Commission.
~
AVERAGE DAILY UNIT POWER LEVEL Docket No. 50-267 Unit Fort S t. Vrain, Lbit No. 1 Date 790801 Completed By J. W. Gahm Telephone (303) 785-2253 Month July, 1979 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (We-Ne t), (We-Ne t) 1 0 17 0 2 0 .8 0 3 0 19 0 4 0 20 0 5 0 21 0 6 0 22 0 7 0 23 60 8 0 24 0*
9 0 25 0 10 0 26 661 11 0 27 1,095 12 0 28 292 13 0 0 29 14 0 30 385 15 0 31 563 16 0
- Generator on line but no net generation.
g 7.. D )
.~ _
REF*lELING INFORMATION
- 1. Name of Facilitv. Fort S t. Vrain, Unit No. 1
- 2. Scheduled date for next refueling shutdown. September 1,1980
- 3. Scheduled date for restart following refueling. November 1, 1980
- 4. Will refueling or resumption of operation thereaf ter require a techni:al specification change or other license amendment? No If answer is yes, what, in general, vill these be?
If answer is no, has the reload The Plant Operations Review Committee fuel design and core configura- will review any questions associated tion been reviewed by your Plant with the core reload.
Saf ety Review Committee to deter-nine whether any unreviewed safety questions are associated with the core reload (Reference i 10CFR Section 50.59)? I If no such review has taken March 1, 1980 olace, when is it scheduled?
- 5. Scheduled date(s) for submitting --
proposed licensing action and succorting information.
- 6. Important licensing considera-tions associated with refueling, e.g., new or different fuel de-sign or supplier, unreviewed design or perfor=ance analysis methods, significant changes in fuel design, new operating pro-cedures.
- 7. The number of fuel assemblies a) 1482 HTGR fuel elements.
(a) in the core and (b) in the scent fuel storage pool, b) 244 spent HTGR fuel elements.
- 8. The present licensed spent fuel Capacity is limited in size to about one pool storage capacity and the third o f co re (approximately 500 HTGR l size of any increase in licensed elements). No change is planned. I storage capacity that has been requested or is planned, in number of fuel assemblies.
0l ,u
REFUELING INFORMATION (CONTINUED)
- 9. The projected date of the l'i86 under the Three Party Agreement (Con-last refueling that can be tract AT (04-3)-633) between DOE, Public discharged to the spent fuel Service Company of Colorado (PSCo), and pool assuming the present General Atomic Company.
- The 1986 date is based on the understanding that spent fuel discharged during the term of the Three Party Agreement will be shipped to the Idaho National Engineering Laboratory for storage by DOE at the Idaho Chemical Processing Plant (ICPP). The storage capacity has evidently been sized to accomodate fuel which is expected to be discharged during the eight year period covered by the Three Party Agreement.
c, 0 Q
, f, l '
% f' 0