SMR DC Docs - FW: NuScale Comments Chapter 5 SER W/Ois
ML19099A127
Person / Time
Site: NuScale
Issue date: 04/09/2019
From:
NRC
To:
NRC/NRO/DLSE/LB1
References
Download: ML19099A127 (4)


Text

NuScaleDCDocsPEm Resource From: Bavol, Bruce Sent: Tuesday, April 9, 2019 8:53 AM To: NuScaleDCDocsPEm Resource

Subject:

FW: RE: NuScale Comments Chapter 5 SER w/OIs From: Norris, Rebecca <RNorris@nuscalepower.com>

Sent: Tuesday, April 02, 2019 3:16 PM To: Bavol, Bruce <Bruce.Bavol@nrc.gov>

Cc: Fosaaen, Carrie <cfosaaen@nuscalepower.com>; Lee, Samuel <Samuel.Lee@nrc.gov>; Mitchell, Matthew

<Matthew.Mitchell@nrc.gov>; Makar, Gregory <Gregory.Makar@nrc.gov>; Terry, Leslie <Leslie.Terry@nrc.gov>;

Melton, Mike <MMelton@nuscalepower.com>

Subject:

[External_Sender] RE: NuScale Comments Chapter 5 SER w/OIs

Bruce, I spoke to my team on this, and we understand the comment and will be changing the FSAR to more clearly indicate SB-163 in Section 5.4.1.5.

Rebecca Norris Supervisor, Licensing email: rnorris@nuscalepower.com web: www.nuscalepower.com office:

From: Bavol, Bruce <Bruce.Bavol@nrc.gov>

Sent: Tuesday, April 2, 2019 7:12 AM To: Norris, Rebecca <RNorris@nuscalepower.com>

Cc: Fosaaen, Carrie <cfosaaen@nuscalepower.com>; Lee, Samuel <Samuel.Lee@nrc.gov>; Mitchell, Matthew

<Matthew.Mitchell@nrc.gov>; Makar, Gregory <Gregory.Makar@nrc.gov>; Terry, Leslie <Leslie.Terry@nrc.gov>;

Melton, Mike <MMelton@nuscalepower.com>

Subject:

NuScale Comments Chapter 5 SER w/OIs

Rebecca, Regarding NuScale comments 12 & 13 (Chapter 5 SER w/OIs):

Staff reviewed NuScales comments on the steam generator materials. Comments 12 & 13 address the same issue about the steam generator tubing material. Comment 12 states:

The NuScale FSAR does not call out use of ASME SB-163 for SG tube material. Recommend deleting ASME SB-163 from this statement. See FSAR section 5.4.1.5.

FSAR Revisions 0 and 1 did call out SB-163 in Tier 2 Section 5.4.1.5, and we missed the change (removal) in Rev. 2.

1

Staff needs to understand the reason for the deleting of ASME SB-163. We need to consider the implications for the material NuScale is planning to use for the steam generator tubing, and its not clear to us how the ASME Code requirements can be met without identifying the ASME Code Section II specification.

Regards, Bruce M. Bavol Project Manager NuScale, Licensing Projects Branch 1 Office of New Reactors Nuclear Regulatory Commission Work Phone: (301) 415-6715 Email: Bruce.Bavol@nrc.gov 2

Hearing Identifier: NuScale_SMR_DC_Docs_Public Email Number: 30 Mail Envelope Properties (BN1PR09MB030555D4C881A3E5BBD24C8AEE2D0)