From:

Chowdhury, Prosanta Sent:

Wednesday, November 27, 2019 11:10 AM To:

NuScaleDCDocsPEm Resource

Subject:

FW: RE: Chapter 18 (DI IP) related (non-prop)

From: Joergensen, Nadja <njoergensen@nuscalepower.com>

Sent: Wednesday, November 06, 2019 8:09 PM To: Chowdhury, Prosanta <Prosanta.Chowdhury@nrc.gov>

Cc: Melton, Mike <MMelton@nuscalepower.com>

Subject:

[External_Sender] RE: Chapter 18 (DI IP) related

Prosanta, NuScale has determined that we can make the change that the NRC requested. The DI IP will be modified to add the text shown in red below.

This IP does not apply to maintenance or refueling activities, activities completed by craft/technical personnel (i.e., mechanical, electrical, or instrumentation and control (I&C),

health physics, chemistry, engineering, or information technology), or activities associated with the technical support center, emergency operations facility, operations support center, or any other emergency response facilities (see Reference 9.2.1) with the exception of Reactor Building crane operation.

Please have the NRC Staff confirm that the modification will resolve the issue.

Thanks, Nadja Nadja Joergensen Licensing Project Manager email: njoergensen@nuscalepower.com web: www.nuscalepower.com Office: 541.452.7338 Cell: 913.709.6300 The contents of this email are intended only for the person to whom it is addressed. If you received it by mistake, please inform me by reply email and then delete the message and any attachments. This email may contain proprietary, confidential and/or privileged material, which doesn't change if it is sent to an unintended recipient. Unless you have my consent, please do not copy, forward, or reveal the contents of this email to anyone.

From: Chowdhury, Prosanta <Prosanta.Chowdhury@nrc.gov>

Sent: Tuesday, November 5, 2019 10:20 AM To: Joergensen, Nadja <njoergensen@nuscalepower.com>

Subject:

Chapter 18 (DI IP) related

Nadja,

The staff does not think PMP needs to be revised/ updated as a result of our discussed potential/proposed changes in the DI IP. In general and as always, NuScale will need to verify any cross references and update accordingly and as necessary.

Prosanta

Hearing Identifier:

NuScale_SMR_DC_Docs_Public Email Number:

36 Mail Envelope Properties (SN6PR09MB366210305F3A9011C76B8E929E440)

Subject:

FW: RE: Chapter 18 (DI IP) related (non-prop)

Sent Date:

11/27/2019 11:10:04 AM Received Date:

11/27/2019 11:10:06 AM From:

Chowdhury, Prosanta Created By:

Prosanta.Chowdhury@nrc.gov Recipients:

"NuScaleDCDocsPEm Resource" <NuScaleDCDocsPEm.Resource@nrc.gov>

Tracking Status: None Post Office:

SN6PR09MB3662.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2298 11/27/2019 11:10:06 AM image001.png 11802 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date: