Init EXAM-4-2000-Draft JPM CCP01 - Shift Lead Charging Pump
ML003716744
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 04/24/2000
From:
NRC Region 4
To:
References
-RFPFR
Download: ML003716744 (5)


Text

JPM- ANO-2-JPM-NRC-CCP01 PAGE 1 OF 5 JOB PERFORMANCE MEASURE UNIT: 2 REV #: 6 DATE:

SYSTEM/DUTY AREA: Pressurizer Level Control System TASK: Shifting Lead Charging Pump JTA#: 20045510401 KA VALUE RO: 3.5 SRO: 3.7 KA

REFERENCE:

011 A2.04 APPROVED FOR ADMINISTRATION TO: RO: X SRO: X TASK LOCATION: INSIDE CR: X OUTSIDE CR: BOTH:

SUGGESTED TESTING ENVIRONMENT AND METHOD (PERFORM OR SIMULATE):

PLANT SITE: SIMULATOR: Perform LAB:

POSITION EVALUATED: RO: SRO:

ACTUAL TESTING ENVIRONMENT: SIMULATOR: X PLANT SITE: LAB:

TESTING METHOD: SIMULATE: PERFORM: X APPROXIMATE COMPLETION TIME IN MINUTES: 5 Minutes REFERENCE(S): OP 2104.002 Rev 038-01-0 EXAMINEE'S NAME: SSN: - -

EVALUATOR'S NAME:

THE EXAMINEE'S PERFORMANCE WAS EVALUATED AGAINST THE STANDARDS CONTAINED IN THIS JPM AND IS DETERMINED TO BE:

SATISFACTORY: UNSATISFACTORY:

PERFORMANCE CHECKLIST COMMENTS:

Start Time Stop Time Total Time SIGNED__________________________________ DATE: _____________________

SIGNATURE INDICATES THIS JPM HAS BEEN COMPARED TO ITS APPLICABLE PROCEDURE BY A QUALIFIED INDIVIDUAL (NOT THE EXAMINEE) AND IS CURRENT WITH THAT REVISION.

THE EXAMINER SHALL REVIEW THE FOLLOWING WITH THE EXAMINEE:

JPM- ANO-2-JPM-NRC-CCP01 PAGE 2 OF 5 JOB PERFORMANCE MEASURE The examiner shall review the "Briefing Checklist - System Walkthrough" portion of OP 1064.023 Attachment 6 with the examinee.

JPM INITIAL TASK CONDITIONS: WCO has requested Charging Pump 2P36B be stopped to perform oil level check. THIS IS AN ALTERNATE SUCCESS PATH JPM.

TASK STANDARD: Shift lead charging pump.

TASK PERFORMANCE AIDS: OP 2104.002 SIMULATOR SETUP: Select "B" as lead charging pump and trigger 2P36C Plunger Break CVC2P36CBRK. 2P36C aligned to green bus.

JPM- ANO-2-JPM-NRC-CCP01 PAGE 3 OF 5 JOB PERFORMANCE MEASURE INITIATING CUE:

The SS/CRS directs, "Shift lead charging pump to 2P36C using OP 2104.002 Section 8.1. Seal water pump has been running for 15 minutes."

CRITICAL ELEMENTS (C): 2 PERFORMANCE CHECKLIST STANDARDS (Circle One)

1. Place selected pump handswitch On 2C09, placed 2HS-4853-2 to N/A SAT UNSAT to START. START. Observed red light ON and green light OFF.

(C) 2. Check Charging Flow goes up ~44 On 2C09, checked Charging Flow N/A SAT UNSAT gpm. (2FIS-4863) and reports flow indicates 60 gpm.

3. Did not get expected response, Placed 2HS-4853-2 to AUTO or N/A SAT UNSAT therefore secure 2P36C. STOP. Observed red light OFF and green light ON.

EXAMINEERS CUE:

Act as CRS and direct examinee to select 2P36A as lead charging pump.

4. Place selected pump handswitch On 2C09, placed 2HS-4832-1 to N/A SAT UNSAT to START. START. Observed red light ON and green light OFF.
5. Check Charging Flow goes up ~44 On 2C09, checks Charging Flow N/A SAT UNSAT gpm. (2FIS-4863) flow indicates ~88 gpm.
6. Place Charging Pump Select On 2C09, placed Charging Pump N/A SAT UNSAT Switch (2HS-4868) to selected lead Select handswitch (2HS-4868) to pump. PMP B&C position.
7. Verify previous lead pump stops. Checked 2P36B stopped. Observed N/A SAT UNSAT red light OFF and green light ON.
8. Check Charging Flow lowers On 2C09, checks Charging Flow N/A SAT UNSAT

~44 gpm. (2FIS-4863) flow indicates ~44 gpm.

9. Place selected pump handswitch On 2C09, placed 2HS-4832-1 to N/A SAT UNSAT to AUTO. AUTO.

END

JPM- ANO-2-JPM-NRC-CCP01 PAGE 4 OF 5 JOB PERFORMANCE MEASURE QUESTION ANSWER

JPM- ANO-2-JPM-NRC-CCP01 PAGE 5 OF 5 JOB PERFORMANCE MEASURE EXAMINEES COPY JPM INITIAL TASK CONDITIONS:

WCO has requested Charging Pump 2P36B be stopped to perform oil level checks.

INITIATING CUE:

The SS/CRS directs, "Shift lead charging pump to 2P36C using OP 2104.002 Section 8.1. Seal water pump has been running for 15 minutes."